Siemens
01 2018
(4872) 700-366
skenergo@mail.ru

3RU2116-0BJ0

.
-

PG
3RU2116-0BJ00.1341F 0.14...0.20 A , S00, 10, . , : , . : , -



More information

 

Home page, see http://www.siemens.com/sirius-overloadrelays

 

TIA Selection Tool Cloud (TST Cloud), see https://mall.industry.siemens.com/spice/TSTWeb?kmat=ElectronicOverloadRelay

 

Conversion tool, e.g. from 3RU11 to 3RU21, see http://www.siemens.com/sirius/conversion-tool

 

Application Manual "SIRIUS Controls with IE3/IE4 Motors", see https://support.industry.siemens.com/cs/ww/en/view/94770820

 

Manual "SIRIUS – SIRIUS 3RU Thermal Overload Relays / SIRIUS 3RB Electronic Overload Relays" see http://support.automation.siemens.com/WW/view/en/60298164

 

Characteristics and certificates see https://support.industry.siemens.com/cs/ww/en/ps/16271

 


Mountable accessories for SIRIUS 3RU21 thermal overload relays

SIRIUS 3RU2136-4.B0 thermal overload relays

3RU21 thermal overload relays up to 100 A have been designed to provide current-dependent protection for loads with normal starting against impermissibly high temperature rises due to overload or phase failure.

An overload or a phase failure result in an increase of the motor current beyond the set rated motor current. Via heating elements, this current rise heats up the bimetal strips inside the device which then bend and as a result trigger the auxiliary contacts by means of a tripping mechanism. The auxiliary contacts then switch off the load by means of a contactor. The break time depends on the ratio between the tripping current and the current setting Ie and is stored in the form of a long-term stable tripping characteristic curve.

The "tripped" status is signaled by means of a switch position indicator. The relay is reset manually or automatically after a recovery time has elapsed.

The 3RU2 thermal overload relays are suitable for operation with frequency converters.

The devices are manufactured in accordance with environmental guidelines and contain environmentally friendly and reusable materials. They comply with all important worldwide standards and approvals.

Use in hazardous areas

The 3RU2 overload relays are certified in accordance with both the European explosion protection directive (ATEX) and the international explosion protection standard (IECEx).

Article No. scheme

Product versions

Article number

Thermal overload relays

 

3RU2

Device type

g. 1 = CLASS 10, 1 NO + 1 NC

 

       

Size, rated operational current and power

e.g. 16 = 16 A (7.5 kW) for size S00

  

     

Setting range for overload release

e.g. 0A = 0.11 ... 0.16 A

     

  

Connection methods

e.g. B = screw terminals

       

 

Installation type

e.g. 0 = for mounting onto contactors

        

Example

 

3RU2

1

1

6

0

A

B

0



Note:

The Article No. scheme shows an overview of product versions for better understanding of the logic behind the article numbers. For your orders please use the article numbers quoted in the selection and ordering data.


















  © " " 2007-2022
  (4872) 700-366  skenergo@mail.ru
.