Motor Modules
General technical specifications

Electrical specifications

Efficiency

> 98.5 %

DC link voltage

(up to 2000 m above sea level)

510 ... 720 V DC (line supply voltage 380 ... 480 V 3 AC) or
675 ... 1035 V DC (line supply voltage 500 ... 690 V 3 AC)

Output frequency 1)

 
  • Control type Servo

0 … 650 Hz

  • Control type Vector

0 … 600 Hz

  • Control type V/f

0 … 600 Hz

Conformity

CE (EMC Directive No. 2004/108/EC and Low-Voltage Directive No. 2006/95/EC)

Approvals, according to

cULus (only for drive units connected to line voltages 380 ... 480 V 3 AC and 500 ... 600 V 3 AC)

Safety Integrated

Safety Integrity Level 2 (SIL2) acc. to IEC 61508, Performance Level d (PLd) acc. to EN ISO 13849-1 and Control Category 3 acc. to EN ISO 13849-1 (previously EN 954-1).



1) Please note:
- The correlation between the maximum output frequency, pulse frequency and current derating. Higher output frequencies for specific configurations are available on request.
- The correlation between the minimum output frequency and permissible output current (current derating).
Information is provided in the SINAMICS Low Voltage Engineering Manual.

Line voltage 380 … 480 V 3 AC
DC link voltage 510 … 720 V DC

Motor Modules

 

6SL3320-1TE32-1AA3

6SL3320-1TE32-6AA3

6SL3320-1TE33-1AA3

6SL3320-1TE33-8AA3

6SL3320-1TE35-0AA3

Type rating

      
  • For IL (50 Hz 400 V) 1)

kW

110

132

160

200

250

  • For IH (50 Hz 400 V) 1)

kW

90

110

132

160

200

  • For IL (60 Hz 460 V) 2)

hp

150

200

250

300

400

  • For IH (60 Hz 460 V) 2)

hp

150

200

200

250

350

Output current

      
  • Rated current IN A

A

210

260

310

380

490

  • Base load current I3)

A

205

250

302

370

477

  • Base load current I4)

A

178

233

277

340

438

  • Maximum current Imax A

A

307

375

453

555

715

DC link current

      
  • Rated current IN DC
    when supplied from
      
  • Basic/Smart Line Module

A

252

312

372

456

588

  • Active Line Module

A

227

281

335

411

529

  • Base load current IL DC 3)
    when supplied from
      
  • Basic/Smart Line Module

A

245

304

362

444

573

  • Active Line Module

A

221

273

326

400

515

  • Base load current IH DC 4)
    when supplied from
      
  • Basic/Smart Line Module

A

224

277

331

405

523

  • Active Line Module

A

202

250

298

365

470

Current demand

      
  • 24 V DC auxiliary power supply

A

0.8

0.8

0.9

0.9

0.9

  • 400 V AC

A

0.63

1.13

1.8

1.8

1.8

DC link capacitance

?F

4200

5200

6300

7800

9600

Pulse frequency 5)

      
  • Rated frequency

kHz

2

2

2

2

2

  • Pulse frequency, max.
      
  • Without current derating

kHz

2

2

2

2

2

  • With current derating

kHz

8

8

8

8

8

Power loss, max. 6)

      
  • At 50 Hz 400 V

kW

1.86

2.5

2.96

3.67

4.28

  • At 60 Hz 460 V

kW

1.94

2.6

3.1

3.8

4.5

Cooling air requirement

m3/s

0.17

0.23

0.36

0.36

0.36

Sound pressure level LpA

(1 m) at 50/60 Hz

dB

64/67

64/67

69/73

69/73

69/73

DC link connection

DCP, DCN

 

M10 screw

M10 screw

M10 screw

M10 screw

M10 screw

  • Conductor cross-section, max. (IEC)

mm2

2 ? 185

2 ? 185

2 ? 240

2 ? 240

2 ? 240

Motor connection

U2, V2, W2

 

M10 screw

M10 screw

M10 screw

M10 screw

M10 screw

  • Conductor cross-section, max. (IEC)

mm2

2 ? 185

2 ? 185

2 ? 240

2 ? 240

2 ? 240

Cable length, max. 7)

      
  • Shielded

m

300

300

300

300

300

  • Unshielded

m

450

450

450

450

450

PE1/GND connection

 

M10 screw

M10 screw

M10 screw

M10 screw

M10 screw

  • Conductor cross-section, max. (IEC)

mm2

2 ? 185

2 ? 185

2 ? 240

2 ? 240

2 ? 240

PE2/GND connection

 

M10 screw

M10 screw

M10 screw

M10 screw

M10 screw

  • Conductor cross-section, max. (IEC)

mm2

2 ? 185

2 ? 185

2 ? 240

2 ? 240

2 ? 240

Degree of protection

 

IP20

IP20

IP20

IP20

IP20

Dimensions

      
  • Width

mm

326

326

326

326

326

  • Height

mm

1400

1400

1533

1533

1533

  • Depth

mm

356

356

545

545

545

Weight, approx.

kg

95

95

136

136

136

Frame size

 

FX

FX

GX

GX

GX



1) Rated power of a typ. 6-pole standard induction motor based on IL or IH with 400 V 3 AC 50 Hz.

2) Rated power of a typ. 6-pole standard induction motor based on IL or IH with 460 V 3 AC 60 Hz.

3) The base load current IL is the basis for a duty cycle of 110 % for 60 s or 150 % for 10 s with a duty cycle duration of 300 s.

4) The base load current IH is the basis for a duty cycle of 150 % for 60 s or 160 % for 10 s with a duty cycle duration of 300 s.

5)Information regarding the correlation between the pulse frequency and maximum output current/output frequency is provided in the SINAMICS Low Voltage Engineering Manual.

6) The specified power loss represents the maximum value at 100 % utilization. The value is lower under normal operating conditions.

7) Sum of all motor cables and DC link. Longer cable lengths for specific configurations are available on request. For additional information, please refer to the SINAMICS Low Voltage Engineering Manual.

Line voltage 380 … 480 V 3 AC
DC link voltage 510 … 720 V DC

Motor Modules

 

6SL3320-1TE36-1AA3

6SL3320-1TE37-5AA3

6SL3320-1TE38-4AA3

Type rating

    
  • For IL (50 Hz 400 V) 1)

kW

315

400

450

  • For IH (50 Hz 400 V) 1)

kW

250

315

400

  • For IL (60 Hz 460 V) 2)

hp

500

600

700

  • For IH (60 Hz 460 V) 2)

hp

350

450

600

Output current

    
  • Rated current IN A

A

605

745

840

  • Base load current I3)

A

590

725

820

  • Base load current I4)

A

460

570

700

  • Maximum current Imax A

A

885

1087

1230

DC link current

    
  • Rated current IN DC
    when supplied from
    
  • Basic/Smart Line Module

A

726

894

1008

  • Active Line Module

A

653

805

907

  • Base load current IL DC 3)
    when supplied from
    
  • Basic/Smart Line Module

A

707

871

982

  • Active Line Module

A

636

784

884

  • Base load current IH DC 4)
    when supplied from
    
  • Basic/Smart Line Module

A

646

795

897

  • Active Line Module

A

581

716

807

Current demand

    
  • 24 V DC auxiliary power supply

A

1.0

1.0

1.0

  • 400 V AC

A

3.6

3.6

3.6

DC link capacitance

?F

12600

15600

16800

Pulse frequency

    
  • Rated frequency

kHz

1.25

1.25

1.25

  • Pulse frequency, max.
    
  • Without current derating

kHz

1.25

1.25

1.25

  • With current derating

kHz

7.5

7.5

7.5

Power loss, max. 6)

    
  • At 50 Hz 400 V

kW

5.84

6.68

7.15

  • At 60 Hz 460 V

kW

6.3

7.3

7.8

Cooling air requirement

m3/s

0.78

0.78

0.78

Sound pressure level LpA

(1 m) at 50/60 Hz

dB

70/73

70/73

70/73

DC link connection

DCP, DCN

 

4 ? hole for M10
Busbar

4 ? hole for M10
Busbar

4 ? hole for M10
Busbar

Motor connection

U2, V2, W2

 

2 ? M12 screw

2 ? M12 screw

2 ? M12 screw

  • Conductor cross-section, max. (IEC)

mm2

4 ? 240

4 ? 240

4 ? 240

Cable length, max. 7)

    
  • Shielded

m

300

300

300

  • Unshielded

m

450

450

450

PE1/GND connection

 

M12 screw

M12 screw

M12 screw

  • Conductor cross-section, max. (IEC)

mm2

240

240

240

PE2/GND connection

 

2 ? M12 screw

2 ? M12 screw

2 ? M12 screw

  • Conductor cross-section, max. (IEC)

mm2

2 ? 240

2 ? 240

2 ? 240

Degree of protection

 

IP00

IP00

IP00

Dimensions

    
  • Width

mm

503

503

503

  • Height

mm

1475

1475

1475

  • Depth

mm

547

547

547

Weight, approx.

kg

290

290

290

Frame size

 

HX

HX

HX



1) Rated power of a typ. 6-pole standard induction motor based on IL or IH with 400 V 3 AC 50 Hz.

2) Rated power of a typ. 6-pole standard induction motor based on IL or IH with 460 V 3 AC 60 Hz.

3) The base load current IL is the basis for a duty cycle of 110 % for 60 s or 150 % for 10 s with a duty cycle duration of 300 s.

4) The base load current IH is the basis for a duty cycle of 150 % for 60 s or 160 % for 10 s with a duty cycle duration of 300 s.

5)Information regarding the correlation between the pulse frequency and maximum output current/output frequency is provided in the SINAMICS Low Voltage Engineering Manual.

6) The specified power loss represents the maximum value at 100 % utilization. The value is lower under normal operating conditions.

7) Sum of all motor cables and DC link. Longer cable lengths for specific configurations are available on request. For additional information, please refer to the SINAMICS Low Voltage Engineering Manual.

Line voltage 380 … 480 V 3 AC
DC link voltage 510 … 720 V DC

Motor Modules

 

6SL3320-1TE41-0AA3

6SL3320-1TE41-2AA3

6SL3320-1TE41-4AA3

Type rating

    
  • For IL (50 Hz 400 V) 1)

kW

560

710

800

  • For IH (50 Hz 400 V) 1)

kW

450

560

710

  • For IL (60 Hz 460 V) 2)

hp

800

1000

1150

  • For IH (60 Hz 460 V) 2)

hp

700

900

1000

Output current

    
  • Rated current IN A

A

985

1260

1405

  • Base load current I3)

A

960

1230

1370

  • Base load current I4)

A

860

1127

1257

  • Maximum current Imax A

A

1440

1845

2055

DC link current

    
  • Rated current IN DC
    when supplied from
    
  • Basic/Smart Line Module

A

1182

1512

1686

  • Active Line Module

A

1064

1361

1517

  • Base load current IL DC 3)
    when supplied from
    
  • Basic/Smart Line Module

A

1152

1474

1643

  • Active Line Module

A

1037

1326

1479

  • Base load current IH DC4)
    when supplied from
    
  • Basic/Smart Line Module

A

1051

1345

1500

  • Active Line Module

A

946

1211

1350

Current demand

    
  • 24 V DC auxiliary power supply

A

1.25

1.40

1.40

  • 400 V AC

A

5.4

5.4

5.4

DC link capacitance

?F

18900

26100

28800

Pulse frequency 5)

    
  • Rated pulse frequency

kHz

1.25

1.25

1.25

  • Pulse frequency, max.
    
  • Without current derating

kHz

1.25

1.25

1.25

  • With current derating

kHz

7.5

7.5

7.5

Power loss, max. 6)

    
  • At 50 Hz 400 V

kW

9.5

11.1

12.0

  • At 60 Hz 460 V

kW

10.2

12.0

13.0

Cooling air requirement

m3/s

1.1

1.1

1.1

Sound pressure level LpA

(1 m) at 50/60 Hz

dB

71/73

71/73

71/73

DC link connection

DCP, DCN

 

4 ? hole for M10
Busbar

4 ? hole for M10
Busbar

4 ? hole for M10
Busbar

Motor connection

U2, V2, W2

 

3 ? M12 screw

3 ? M12 screw

3 ? M12 screw

  • Conductor cross-section, max. (IEC)

mm2

6 ? 240

6 ? 240

6 ? 240

Cable length, max. 7)

    
  • Shielded

m

300

300

300

  • Unshielded

m

450

450

450

PE1/GND connection

 

M12 screw

M12 screw

M12 screw

  • Conductor cross-section, max. (IEC)

mm2

240

240

240

PE2/GND connection

 

3 ? M12 screw

3 ? M12 screw

3 ? M12 screw

  • Conductor cross-section, max. (IEC)

mm2

3 ? 240

3 ? 240

3 ? 240

Degree of protection

 

IP00

IP00

IP00

Dimensions

 

   
  • Width

mm

704

704

704

  • Height

mm

1475

1475

1475

  • Depth

mm

549

549

549

Weight, approx.

kg

450

450

450

Frame size

 

JX

JX

JX



1) Rated power of a typ. 6-pole standard induction motor based on IL or IH with 400 V 3 AC 50 Hz.

2) Rated power of a typ. 6-pole standard induction motor based on IL or IH with 460 V 3 AC 60 Hz.

3) The base load current IL is the basis for a duty cycle of 110 % for 60 s or 150 % for 10 s with a duty cycle duration of 300 s.

4) The base load current IH is the basis for a duty cycle of 150 % for 60 s or 160 % for 10 s with a duty cycle duration of 300 s.

5)Information regarding the correlation between the pulse frequency and maximum output current/output frequency is provided in the SINAMICS Low Voltage Engineering Manual.

6) The specified power loss represents the maximum value at 100 % utilization. The value is lower under normal operating conditions.

7) Sum of all motor cables and DC link. Longer cable lengths for specific configurations are available on request. For additional information, please refer to the SINAMICS Low Voltage Engineering Manual.

Line voltage 500 … 690 V 3 AC
DC link voltage 675 … 1035 V DC 

Motor Modules

 

6SL3320-1TG28-5AA3

6SL3320-1TG31-0AA3

6SL3320-1TG31-2AA3

6SL3320-1TG31-5AA3

Type rating

     
  • For IL (50 Hz 690 V) 1)

kW

75

90

110

132

  • For IH (50 Hz 690 V) 1)

kW

55

75

90

110

  • For IL (50 Hz 500 V) 1)

kW

55

55

75

90

  • For IH (50 Hz 500 V) 1)

kW

45

55

75

90

  • For IL (60 Hz 575 V) 2)

hp

75

75

100

150

  • For IH (60 Hz 575 V) 2)

hp

75

75

100

125

Output current

     
  • Rated current IN A

A

85

100

120

150

  • Base load current I3)

A

80

95

115

142

  • Base load current I4)

A

76

89

107

134

  • Maximum current Imax A

A

120

142

172

213

DC link current

     
  • Rated current IN DC
    when supplied from
     
  • Basic/Smart Line Module

A

102

120

144

180

  • Active Line Module

A

92

108

130

162

  • Base load current IL DC 3)
    when supplied from
     
  • Basic/Smart Line Module

A

99

117

140

175

  • Active Line Module

A

89

105

126

157

  • Base load current IH DC 4)
    when supplied from
     
  • Basic/Smart Line Module

A

90

106

128

160

  • Active Line Module

A

81

96

115

144

Current demand

     
  • 24 V DC auxiliary power supply

A

0.8

0.8

0.8

0.8

  • 500 V AC

A

0.7

0.7

0.7

0.7

  • 690 V AC

A

0.4

0.4

0.4

0.4

DC link capacitance

?F

1200

1200

1600

2800

Pulse frequency 5)

     
  • Rated frequency

kHz

1.25

1.25

1.25

1.25

  • Pulse frequency, max.
     
  • Without current derating

kHz

1.25

1.25

1.25

1.25

  • With current derating

kHz

7.5

7.5

7.5

7.5

Power loss, max. 6)

     
  • At 50 Hz 690 V

kW

1.17

1.43

1.89

1.80

  • At 60 Hz 575 V

kW

1.1

1.3

1.77

1.62

Cooling air requirement

m3/s

0.17

0.17

0.17

0.17

Sound pressure level LpA

(1 m) at 50/60 Hz

dB

64/67

64/67

64/67

64/67

DC link connection

DCP, DCN

 

M10 screw

M10 screw

M10 screw

M10 screw

  • Conductor cross-section, max. (IEC)

mm2

2 ? 185

2 ? 185

2 ? 185

2 ? 185

Motor connection

U2, V2, W2

 

M10 screw

M10 screw

M10 screw

M10 screw

  • Conductor cross-section, max. (IEC)

mm2

2 ? 185

2 ? 185

2 ? 185

2 ? 185

Cable length, max. 7)

     
  • Shielded

m

300

300

300

300

  • Unshielded

m

450

450

450

450

PE1/GND connection

 

M10 screw

M10 screw

M10 screw

M10 screw

  • Conductor cross-section, max. (IEC)

mm2

2 ? 185

2 ? 185

2 ? 185

2 ? 185

PE2/GND connection

 

M10 screw

M10 screw

M10 screw

M10 screw

  • Conductor cross-section, max. (IEC)

mm2

2 ? 185

2 ? 185

2 ? 185

2 ? 185

Degree of protection

 

IP20

IP20

IP20

IP20

Dimensions

     
  • Width

mm

326

326

326

326

  • Height

mm

1400

1400

1400

1400

  • Depth

mm

356

356

356

356

Weight, approx.

kg

95

95

95

95

Frame size

 

FX

FX

FX

FX



1) Rated power of a typ. 6-pole standard induction motor based on IL or IH at 500 V or 690 V 3 AC 50 Hz.

2) Rated power of a typ. 6-pole standard induction motor based on IL or IH at 575 V 3 AC 60 Hz.

3) The base load current IL is the basis for a duty cycle of 110 % for 60 s or 150 % for 10 s with a duty cycle duration of 300 s.

4) The base load current IH is the basis for a duty cycle of 150 % for 60 s or 160 % for 10 s with a duty cycle duration of 300 s.

5)Information regarding the correlation between the pulse frequency and maximum output current/output frequency is provided in the SINAMICS Low Voltage Engineering Manual.

6) The specified power loss represents the maximum value at 100 % utilization. The value is lower under normal operating conditions.

7) Sum of all motor cables and DC link. Longer cable lengths for specific configurations are available on request. For additional information, please refer to the SINAMICS Low Voltage Engineering Manual.

Line voltage 500 … 690 V 3 AC
DC link voltage 675 … 1035 V DC 

Motor Modules

 

6SL3320-1TG31-8AA3

6SL3320-1TG32-2AA3

6SL3320-1TG32-6AA3

6SL3320-1TG33-3AA3

Type rating

     
  • For IL (50 Hz 690 V) 1)

kW

160

200

250

315

  • For IH (50 Hz 690 V) 1)

kW

132

160

200

250

  • For IL (50 Hz 500 V) 1)

kW

110

132

160

200

  • For IH (50 Hz 500 V) 1)

kW

90

110

132

160

  • For IL (60 Hz 575 V) 2)

hp

150

200

250

300

  • For IH (60 Hz 575 V) 2)

hp

150

200

200

250

Output current

     
  • Rated current IN A

A

175

215

260

330

  • Base load current I3)

A

171

208

250

320

  • Base load current I4)

A

157

192

233

280

  • Maximum current Imax A

A

255

312

375

480

DC link current

     
  • Rated current IN DC
    when supplied from
     
  • Basic/Smart Line Module

A

210

258

312

396

  • Active Line Module

A

189

232

281

356

  • Base load current IL DC 3)
    when supplied from
     
  • Basic/Smart Line Module

A

204

251

304

386

  • Active Line Module

A

184

226

273

347

  • Base load current IH DC 4)
    when supplied from
     
  • Basic/Smart Line Module

A

186

229

277

352

  • Active Line Module

A

168

206

250

316

Current demand

     
  • 24 V DC auxiliary power supply

A

0.9

0.9

0.9

0.9

  • 500 V AC

A

1.5

1.5

1.5

1.5

  • 690 V AC

A

1.0

1.0

1.0

1.0

DC link capacitance

?F

2800

2800

3900

4200

Pulse frequency

     
  • Rated frequency

kHz

1.25

1.25

1.25

1.25

  • Pulse frequency, max.
     
  • Without current derating

kHz

1.25

1.25

1.25

1.25

  • With current derating

kHz

7.5

7.5

7.5

7.5

Power loss, max. 6)

     
  • At 50 Hz 690 V

kW

2.67

3.09

3.62

4.34

  • At 60 Hz 575 V

kW

2.5

2.91

3.38

3.98

Cooling air requirement

m3/s

0.36

0.36

0.36

0.36

Sound pressure level LpA

(1 m) at 50/60 Hz

dB

69/73

69/73

69/73

69/73

DC link connection

DCP, DCN

 

M10 screw

M10 screw

M10 screw

M10 screw

  • Conductor cross-section, max. (IEC)

mm2

2 ? 240

2 ? 240

2 ? 240

2 ? 240

Motor connection

U2, V2, W2

 

M10 screw

M10 screw

M10 screw

M10 screw

  • Conductor cross-section, max. (IEC)

mm2

2 ? 240

2 ? 240

2 ? 240

2 ? 240

Cable length, max. 7)

     
  • Shielded

m

300

300

300

300

  • Unshielded

m

450

450

450

450

PE1/GND connection

 

M10 screw

M10 screw

M10 screw

M10 screw

  • Conductor cross-section, max. (IEC)

mm2

2 ? 240

2 ? 240

2 ? 240

2 ? 240

PE2/GND connection

 

M10 screw

M10 screw

M10 screw

M10 screw

  • Conductor cross-section, max. (IEC)

mm2

2 ? 240

2 ? 240

2 ? 240

2 ? 240

Degree of protection

 

IP20

IP20

IP20

IP20

Dimensions

     
  • Width

mm

326

326

326

326

  • Height

mm

1533

1533

1533

1533

  • Depth

mm

545

545

545

545

Weight, approx.

kg

136

136

136

136

Frame size

 

GX

GX

GX

GX



1) Rated power of a typ. 6-pole standard induction motor based on IL or IH at 500 V or 690 V 3 AC 50 Hz.

2) Rated power of a typ. 6-pole standard induction motor based on IL or IH at 575 V 3 AC 60 Hz.

3) The base load current IL is the basis for a duty cycle of 110 % for 60 s or 150 % for 10 s with a duty cycle duration of 300 s.

4) The base load current IH is the basis for a duty cycle of 150 % for 60 s or 160 % for 10 s with a duty cycle duration of 300 s.

5)Information regarding the correlation between the pulse frequency and maximum output current/output frequency is provided in the SINAMICS Low Voltage Engineering Manual.

6) The specified power loss represents the maximum value at 100 % utilization. The value is lower under normal operating conditions.

7) Sum of all motor cables and DC link. Longer cable lengths for specific configurations are available on request. For additional information, please refer to the SINAMICS Low Voltage Engineering Manual.

Line voltage 500 … 690 V 3 AC
DC link voltage 675 … 1035 V DC

Motor Modules

 

6SL3320-1TG34-1AA3

6SL3320-1TG34-7AA3

6SL3320-1TG35-8AA3

6SL3320-1TG37-4AA3

Type rating

     
  • For IL (50 Hz 690 V) 1)

kW

400

450

560

710

  • For IH (50 Hz 690 V) 1)

kW

315

400

450

630

  • For IL (50 Hz 500 V) 1)

kW

250

315

400

500

  • For IH (50 Hz 500 V) 1)

kW

200

250

315

450

  • For IL (60 Hz 575 V) 2)

hp

400

450

600

700

  • For IH (60 Hz 575 V) 2)

hp

350

450

500

700

Output current

     
  • Rated current IN A

A

410

465

575

735

  • Base load current I3)

A

400

452

560

710

  • Base load current I4)

A

367

416

514

657

  • Maximum current Imax A

A

600

678

840

1065

DC link current

     
  • Rated current IN DC
    when supplied from
     
  • Basic/Smart Line Module

A

492

558

690

882

  • Active Line Module

A

443

502

621

794

  • Base load current IL DC 3)
    when supplied from
     
  • Basic/Smart Line Module

A

479

544

672

859

  • Active Line Module

A

431

489

605

774

  • Base load current IH DC 4)
    when supplied from
     
  • Basic/Smart Line Module

A

437

496

614

784

  • Active Line Module

A

394

446

552

706

Current demand

     
  • 24 V DC auxiliary power supply

A

1.0

1.0

1.0

1.25

  • 500 V AC

A

3.0

3.0

3.0

4.4

  • 690 V AC

A

2.1

2.1

2.1

3.1

DC link capacitance

?F

7400

7400

7400

11100

Pulse frequency 5)

     
  • Rated frequency

kHz

1.25

1.25

1.25

1.25

  • Pulse frequency, max.
     
  • Without current derating

kHz

1.25

1.25

1.25

1.25

  • With current derating

kHz

7.5

7.5

7.5

7.5

Power loss, max. 6)

     
  • At 50 Hz 690 V

kW

6.13

6.80

10.3

10.9

  • At 60 Hz 575 V

kW

5.71

6.32

9.7

10

Cooling air requirement

m3/s

0.78

0.78

0.78

1.474

Sound pressure level LpA

(1 m) at 50/60 Hz

dB

70/73

70/73

70/73

71/73

DC link connection

DCP, DCN

 

4 ? hole for M10
Busbar

4 ? hole for M10
Busbar

4 ? hole for M10
Busbar

4 ? hole for M10
Busbar

Motor connection

U2, V2, W2

 

2 ? M12 screw

2 ? M12 screw

2 ? M12 screw

3 ? M12 screw

  • Conductor cross-section, max. (IEC)

mm2

4 ? 240

4 ? 240

4 ? 240

6 ? 240

Cable length, max. 7)

     
  • Shielded

m

300

300

300

300

  • Unshielded

m

450

450

450

450

PE1/GND connection

 

M12 screw

M12 screw

M12 screw

M12 screw

  • Conductor cross-section, max. (IEC)

mm2

240

240

240

240

PE2/GND connection

 

2 ? M12 screw

2 ? M12 screw

2 ? M12 screw

3 ? M12 screw

  • Conductor cross-section, max. (IEC)

mm2

2 ? 240

2 ? 240

2 ? 240

3 ? 240

Degree of protection

 

IP00

IP00

IP00

IP00

Dimensions

     
  • Width

mm

503

503

503

704

  • Height

mm

1475

1475

1475

1475

  • Depth

mm

547

547

547

550

Weight, approx.

kg

290

290

290

450

Frame size

 

HX

HX

HX

JX



1) Rated power of a typ. 6-pole standard induction motor based on IL or IH at 500 V or 690 V 3 AC 50 Hz.

2) Rated power of a typ. 6-pole standard induction motor based on IL or IH at 575 V 3 AC 60 Hz.

3) The base load current IL is the basis for a duty cycle of 110 % for 60 s or 150 % for 10 s with a duty cycle duration of 300 s.

4) The base load current IH is the basis for a duty cycle of 150 % for 60 s or 160 % for 10 s with a duty cycle duration of 300 s.

5)Information regarding the correlation between the pulse frequency and maximum output current/output frequency is provided in the SINAMICS Low Voltage Engineering Manual.

6) The specified power loss represents the maximum value at 100 % utilization. The value is lower under normal operating conditions.

7) Sum of all motor cables and DC link. Longer cable lengths for specific configurations are available on request. For additional information, please refer to the SINAMICS Low Voltage Engineering Manual.

Line voltage 500 … 690 V 3 AC
DC link voltage 675 … 1035 V DC

Motor Modules

 

6SL3320-1TG38-1AA3

6SL3320-1TG38-8AA3

6SL3320-1TG41-0AA3

6SL3320-1TG41-3AA3

Type rating

     
  • For IL (50 Hz 690 V) 1)

kW

800

900

1000

1200

  • For IH (50 Hz 690 V) 1)

kW

710

800

900

1000

  • For IL (50 Hz 500 V) 1)

kW

560

630

710

900

  • For IH (50 Hz 500 V) 1)

kW

500

560

630

800

  • For IL (60 Hz 575 V) 2)

hp

800

900

1000

1250

  • For IH (60 Hz 575 V) 2)

hp

700

800

900

1000

Output current

     
  • Rated current IN A

A

810

910

1025

1270

  • Base load current I3)

A

790

880

1000

1230

  • Base load current I4)

A

724

814

917

1136

  • Maximum current Imax A

A

1185

1320

1500

1845

DC link current

     
  • Rated current IN DC
    when supplied from
     
  • Basic/Smart Line Module

A

972

1092

1230

1524

  • Active Line Module

A

875

983

1107

1372

  • Base load current IL DC 3)
    when supplied from
     
  • Basic/Smart Line Module

A

947

1064

1199

1485

  • Active Line Module

A

853

958

1079

1337

  • Base load current IH DC 4)
    when supplied from
     
  • Basic/Smart Line Module

A

865

971

1094

1356

  • Active Line Module

A

778

874

985

1221

Current demand

     
  • 24 V DC auxiliary power supply

A

1.25

1.4

1.4

1.4

  • 500 V AC

A

4.4

4.4

4.4

4.4

  • 690 V AC

A

3.1

3.1

3.1

3.1

DC link capacitance

?F

11100

14400

14400

19200

Pulse frequency 5)

     
  • Rated frequency

kHz

1.25

1.25

1.25

1.25

  • Pulse frequency, max.
     
  • Without current derating

kHz

1.25

1.25

1.25

1.25

  • With current derating

kHz

7.5

7.5

7.5

7.5

Power loss, max. 6)

     
  • At 50 Hz 690 V

kW

11.5

11.7

13.2

16.0

  • At 60 Hz 575 V

kW

10.5

10.6

12.0

14.2

Cooling air requirement

m3/s

1.474

1.474

1.474

1.474

Sound pressure level LpA

(1 m) at 50/60 Hz

dB

71/73

71/73

71/73

71/73

DC link connection

DCP, DCN

 

4 ? hole for M10
Busbar

4 ? hole for M10
Busbar

4 ? hole for M10
Busbar

4 ? hole for M10
Busbar

Motor connection

U2, V2, W2

 

3 ? M12 screw

3 ? M12 screw

3 ? M12 screw

3 ? M12 screw

  • Conductor cross-section, max. (IEC)

mm2

6 ? 240

6 ? 240

6 ? 240

6 ? 240

Cable length, max. 7)

     
  • Shielded

m

300

300

300

300

  • Unshielded

m

450

450

450

450

PE1/GND connection

 

M12 screw

M12 screw

M12 screw

M12 screw

  • Conductor cross-section, max. (IEC)

mm2

240

240

240

240

PE2/GND connection

 

3 ? M12 screw

3 ? M12 screw

3 ? M12 screw

3 ? M12 screw

  • Conductor cross-section, max. (IEC)

mm2

3 ? 240

3 ? 240

3 ? 240

3 ? 240

Degree of protection

 

IP00

IP00

IP00

IP00

Dimensions

     
  • Width

mm

704

704

704

704

  • Height

mm

1480

1480

1480

1475

  • Depth

mm

549

549

549

550

Weight, approx.

kg

450

450

450

450

Frame size

 

JX

JX

JX

JX



1) Rated power of a typ. 6-pole standard induction motor based on IL or IH at 500 V or 690 V 3 AC 50 Hz.

2) Rated power of a typ. 6-pole standard induction motor based on IL or IH at 575 V 3 AC 60 Hz.

3) The base load current IL is the basis for a duty cycle of 110 % for 60 s or 150 % for 10 s with a duty cycle duration of 300 s.

4) The base load current IH is the basis for a duty cycle of 150 % for 60 s or 160 % for 10 s with a duty cycle duration of 300 s.

5) Information regarding the correlation between the pulse frequency and maximum output current/output frequency is provided in the SINAMICS Low Voltage Engineering Manual.

6) The specified power loss represents the maximum value at 100 % utilization. The value is lower under normal operating conditions.

7) Sum of all motor cables and DC link. Longer cable lengths for specific configurations are available on request. For additional information, please refer to the SINAMICS Low Voltage Engineering Manual.

















skener.ru

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Àðìàòóðà DENDOR

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Äàò÷èêè è èçìåðèòåëè

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Ðåãóëÿòîðû è ðåãèñòðàòîðû

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Ïíåâìàòè÷åñêîå îáîðóäîâàíèå

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Êðàíû è Êëàïàíû

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Èçìåðèòåëüíûå ïðèáîðû

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Ñèñòåìû áåñïðîâîäíîãî óïðàâëåíèÿ «óìíûé äîì»

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Áåñêîíòàêòíûå âûêëþ÷àòåëè Êîíå÷íûå âûêëþ÷àòåëè Îïòè÷åñêèå äàò÷èêè Ýíêîäåðû

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
SKW-FS - Óñòàíîâêà óìÿã÷åíèÿ

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
SKW-FK - Óñòàíîâêà îáåçæåëåçèâàíèÿ
Êàòàëîã îáîðóäîâàíèÿ 2016
Êàòàëîã ïðîäóêòîâ Siemens Industry Ïðèâîäíàÿ òåõíèêà Ïðåîáðàçîâàòåëè Ñòàíäàðòíûå ïðåîáðàçîâàòåëè Îáùàÿ èíôîðìàöèÿ î áàçîâûõ ïðåîáðàçîâàòåëÿõ SINAMICS V Ïðåîáðàçîâàòåëè ÷àñòîòû îáùåãî íàçíà÷åíèÿ SINAMICS G Âûñîêîïðîèçâîäèòåëüíûå ïðåîáðàçîâàòåëè SINAMICS S Ñåðâîïðåîáðàçîâàòåëü SINAMICS S110 SINAMICS S120 SINAMICS S120M distributed servo drive SINAMICS S120 Combi SINAMICS S120 Chassis Format Units Air-cooled units Power Modules Basic Line Modules Smart Line Modules Active Line Modules Active Interface Modules Motor Modules Mounting device for power blocks Liquid-cooled units System components SINAMICS S120 Cabinet Modules SINAMICS S150 MICROMASTER SIPLUS POSMO A SIMODRIVE POSMO LOHER DYNAVERT Drive System Ïðåîáðàçîâàòåëè íà ñðåäíåå íàïðÿæåíèå Ïðåîáðàçîâàòåëè ïîñòîÿííîãî òîêà Äâèãàòåëè ïåðåìåííîãî òîêà Ìîòîð-ðåäóêòîðû Flender Gear Units Couplings Èíñòðóìåíòàëüíîå ïðîãðàììíîå îáåñïå÷åíèå Äîïîëíèòåëüíûå êîìïîíåíòû Òåõíèêà àâòîìàòèçàöèè Àâòîìàòèçàöèÿ è áåçîïàñíîñòü çäàíèé Íèçêîâîëüòíàÿ êîììóòàöèîííàÿ òåõíèêà Òåõíîëîãèÿ áåçîïàñíîñòè Ñèñòåìíûå ðåøåíèÿ è ïðîäóêòû äëÿ îòðàñëåé Ñåðâèñ ... è âñå, ÷òî Âàì åùå íåîáõîäèìî




  © ÎÎÎ "ÑÊ ÝÍÅÐÃÎ" 2007-2022
  (4872) 700-366  skenergo@mail.ru
ßíäåêñ.Ìåòðèêà