Общее19“ unit- With 4 HU for installation
- in swing frame
- in cabinets, with or without slide rails
- Front panel for service can be hinged down (laptop connection)
- Internal gas paths: pipe made of stainless steel
- Gas connections for sample gas input and output and for reference gas: stubs, pipe diameter 6 mm or 1/4".
Field unit- Two-door housing (IP65) with gas-tight separation of analyzer and electronics section
- Sections can be purged separately
- Gas path and pipe couplings made of stainless steel (type No. 1.4571)
- Purging gas connections: pipe diameter 10 mm or 3/8"
- Gas connections for sample gas input and output and for reference gas: clamping ring connection for pipe diameter 6 mm or ?“.
Display and control panel- Large LCD panel for simultaneous display of:
- Measured value (digital and analog displays)
- Status line
- Measuring ranges
- Contrast of LCD panel adjustable using menu
- Permanent LED backlighting
- Washable membrane keyboard/front panel with five softkeys
- Menu-based operation for configuration, test functions and calibration
- User help in plain text
- Graphic display of concentration trend; programmable time intervals
- Operating software in two languages: German/English, English/Spanish, French/English, Spanish/English, Italian/English.
Inputs and outputs- One analog output
- Two analog inputs programmable (e.g. for correction of cross interferences or external pressure sensor)
- Six binary inputs freely configurable (e.g. for range switching, processing external signals from sample conditioning)
- Six relay outputs freely configurable (e.g. for failure, maintenance request, limit alarm, external solenoid valves)
- Extension with eight additional binary inputs and eight additional relay outputs (e.g. for automatic calibration with up to four calibration gases).
Communication- RS 485 present in basic unit (connection at the rear, with 19“ unit also possibility of connection behind the front plate).
Options - RS 485/RS 232 converter
- RS 485/Ethernet converter
- Linking to networks via PROFIBUS DP/PA interface
- SIPROM GA software as service and maintenance tool.
 CALOMAT 6, membrane keyboard and graphic display Versions – Wetted partsGas path | 19“ unit | Field unit | Field unit Ex |
|---|
With pipes | Bushing | SS, type No. 1.4571 | | | Pipe | SS, type No. 1.4571 | | | Sample cell body | SS, type No. 1.4571 | | | O-rings | FFKM - Chemraz | | | Sensor | Si, SiOxNy, AU, epoxy resin, glass | | | Tightness | leakage < 1 ?l/s |
 CALOMAT 6, 19“ unit, gas path  CALOMAT 6, field unit, gas path
|
|