Selection features
|
|
Integral safety functions according to Category 3 of EN 954-1 and according to SIL 2 of IEC 61508
|
- Safe Torque Off (STO)
- Safely Limited Speed (SLS)1)
- Safe Stop 1 (SS1) 1)
- Activation of the integral safety functions through Safety Local Isolator Module F-RSM or via F-Switch PROFIsafe
|
|
Electrical data
|
|
Line voltage
|
380 V to 480 V 3 AC +10 % / -10 %
|
|
Output (at 0 °C to 55 °C ambient temperature)
|
1.1 kW
|
|
Rated input current (at 0 °C to 55 °C ambient temperature)
|
2.0 A
|
|
Rated output current
(at 0 °C to 55 °C ambient temperature)
|
3.5 A
|
|
Output (at 0 °C to 45 °C ambient temperature)
|
1.5 kW
|
|
Rated input current (at 0 °C to 45 °C ambient temperature)
|
2.5 A
|
|
Rated output current (at 0 °C to 45 °C ambient temperature)
|
3.9 A
|
|
Line frequency
|
47 Hz to 63 Hz
|
|
Overload capability
|
- Overload current 1.5 x rated output current (i.e. 150 % overload) for 60 s, cycle time 300 s
- Overload current 2 x rated output current (i.e. 200 % overload) for 3 s, cycle time 300 s
|
|
Output frequency
|
0 Hz to 650 Hz
|
|
Pulse frequency
|
4 kHz (standard), 2 kHz to 16 kHz (in 2 kHz steps)
|
|
SCCR (Short Circuit Current Rating)2)
|
10 kA
|
|
Skipped frequency range
|
1, programmable
|
|
Converter efficiency
|
?96 %
|
|
Interfaces
|
- Connection to PROFIBUS (PROFINET available soon) over the ET 200pro backplane bus
- Optical interface with USS protocol for optical RS232 connecting cable
- Slot for an optional memory card (MMC) for uploading or downloading parameter settings
- PTC/KTY84 interface for motor temperature monitoring
|
|
Functions
|
|
Open-loop/closed-loop control procedure
|
-
V/f control – linear (M~n) with/without flux current control (FCC), quadratic (M~n 2) or parameterizable
- Vector closed-loop control without encoder
- Closed-loop torque control
|
|
Operating functions
|
Jogging mode, free function blocks (FFB), positioning deceleration ramp, automatic restart following interruption due to power failure, bumpless connection of converter to rotating motor
|
|
Braking functions
|
- Regenerative braking operation without brake chopper and pulse resistor
- Contol of an electromagnetic holding brake 180 V DC
|
|
Protective functions
|
Undervoltage, overvoltage, ground faults, short circuits, stall prevention, thermal motor protection (I2t, or sensor), converter overtemperature, motor blocking protection
|
|
Connectable motors
|
- Low-voltage asynchronous motors
- Motor cable lengths: max. 15 m (shielded)
|
|
Mechanical data
|
|
Degree of protection
|
IP65
|
|
Operating temperature
|
0 °C to +55 °C
Increased output at 0 °C to +45 °C
|
|
Mounting position
|
Vertical wall mounting (vertical alignment of the cooling fins)
|
|
Mounting dimensions (W x H x D) in mm (including terminal module)
|
155 x 230 x 213
|
|
Weight
|
4.0 kg
|
|
Standards
|
|
Compliance with standards
|
UL, cUL, CE, low voltage directive 73/23/EEC, EMC directive 89/336/EEC
|