Selection features |
Integrated safety functions acc. to IEC 61508 SIL 2 and EN ISO 13849?1 PL d and Category 3 | - Safe Torque Off (STO)
- Control of the integrated safety function via the Safety Local isolator module F?RSM or via F?Switch PROFIsafe
|
Electrical data |
Line voltage | 380 ... 480 V 3 AC ±10 % |
Power | |
- With an ambient temperature of 0 ... 55° C
| 1.1 kW |
- With an ambient temperature of 0 ... 45° C
| 1.5 kW |
Rated input current / output current | |
- With an ambient temperature of 0 ... 55° C
| 2 A/3.5 A |
- With an ambient temperature of 0 ... 45° C
| 2.5 A/3.9 A |
Line frequency | 47 ... 63 Hz |
Overload capability | - Overload current 1.5 x rated output current (i.e. 150 % overload) for 60 s, cycle time 300 s
- Overload current 2 x rated output current (i.e. 200 % overload) for 3 s, cycle time 300 s
|
Output frequency | 0 ... 550 Hz |
Pulse frequency | 4 kHz (standard) 4 ... 16 kHz (in 2 kHz increments) |
Standard SCCR (Short Circuit Current Rating) | 10 kA |
Skipped frequency range | 1, programmable |
Converter efficiency | 95 ... 97 % |
Interfaces | - Connection to PROFIBUS and PROFINET over the SIMATIC ET 200pro backplane bus
- Mini USB interface for commissioning via PC (as from STARTER V4.4 plus SSP)
- Optical interface for commissioning via the IOP Handheld
- Slot for an optional memory card (SD) to upload or download parameter settings
- PTC, bimetal, KTY84, Pt1000 interface for motor temperature monitoring
|
Functions |
Open-loop/closed-loop control techniques | - V/f control – linear (M ~ n) with/without flux current control (FCC), quadratic (M ~ n2) or parameterizable
- Vector control – sensorless
- Closed-loop torque control
|
Operating functions | - Jogging
- BICO technology
- Automatic restart following interruptions in operation due to a power failure
- Smooth connection of converter to rotating motor
|
Braking functions | - Integrated regenerative feedback functionality
- Control of an electromagnetic holding brake
|
Integrated brake control supplies DC power supply to the brake |
Line voltage | 380 V AC | 400 V AC | 440 V AC | 480 V AC |
Rectified brake voltage | 171 V DC | 180 V DC | 198 V DC | 216 V DC |
Recommended brake coil voltage for Siemens motors | 170 ... 200 V DC | 170 ... 200 V DC 184 ... 218 V DC | 184 ... 218 V DC | 184 ... 218 V DC |
Disconnection on the DC side permits "fast" braking. |
Protective functions | - Undervoltage
- Overvoltage
- Ground fault
- Short-circuit
- Stall protection
- Thermal motor protection (I2t or sensor)
- Converter overtemperature
- Motor blocking protection
- Phase failure detection
|
Connectable motors | - Low-voltage induction motors
- Motor cable lengths: max. 15 m (shielded)
|
Mechanical data |
Degree of protection | IP65 |
Operating temperature | 0 ... +55 °C (32 ... +131 °F) |
Mounting position | Vertical wall mounting (vertical alignment of the cooling fins) |
Dimensions (W ? H ? D) | 155 mm ? 246 mm ? 248 mm |
Weight, approx. | 4 kg |
Standards |
Certificates of suitability | UL508C, cUL, CE, Low Voltage Directive 2014/35/EU, EMC Directive 2014/30/EU |