Selection features |
Integral safety functions according to Category 3 of EN 954-1 and according to SIL 2 of IEC 61508 | - Safe Torque Off (STO)
- Safely Limited Speed (SLS)1)
- Safe Stop 1 (SS1) 1)
- Activation of the integral safety functions through Safety Local Isolator Module F-RSM or via F-Switch PROFIsafe
|
Electrical data |
Line voltage | 380 V to 480 V 3 AC +10 % / -10 % |
Output (at 0 °C to 55 °C ambient temperature) | 1.1 kW |
Rated input current (at 0 °C to 55 °C ambient temperature) | 2.0 A |
Rated output current (at 0 °C to 55 °C ambient temperature) | 3.5 A |
Output (at 0 °C to 45 °C ambient temperature) | 1.5 kW |
Rated input current (at 0 °C to 45 °C ambient temperature) | 2.5 A |
Rated output current (at 0 °C to 45 °C ambient temperature) | 3.9 A |
Line frequency | 47 Hz to 63 Hz |
Overload capability | - Overload current 1.5 x rated output current (i.e. 150 % overload) for 60 s, cycle time 300 s
- Overload current 2 x rated output current (i.e. 200 % overload) for 3 s, cycle time 300 s
|
Output frequency | 0 Hz to 650 Hz |
Pulse frequency | 4 kHz (standard), 2 kHz to 16 kHz (in 2 kHz steps) |
SCCR (Short Circuit Current Rating)2) | 10 kA |
Skipped frequency range | 1, programmable |
Converter efficiency | ?96 % |
Interfaces | - Connection to PROFIBUS (PROFINET available soon) over the ET 200pro backplane bus
- Optical interface with USS protocol for optical RS232 connecting cable
- Slot for an optional memory card (MMC) for uploading or downloading parameter settings
- PTC/KTY84 interface for motor temperature monitoring
|
Functions |
Open-loop/closed-loop control procedure | - V/f control – linear (M~n) with/without flux current control (FCC), quadratic (M~n 2) or parameterizable
- Vector closed-loop control without encoder
- Closed-loop torque control
|
Operating functions | Jogging mode, free function blocks (FFB), positioning deceleration ramp, automatic restart following interruption due to power failure, bumpless connection of converter to rotating motor |
Braking functions | - Regenerative braking operation without brake chopper and pulse resistor
- Contol of an electromagnetic holding brake 180 V DC
|
Protective functions | Undervoltage, overvoltage, ground faults, short circuits, stall prevention, thermal motor protection (I2t, or sensor), converter overtemperature, motor blocking protection |
Connectable motors | - Low-voltage asynchronous motors
- Motor cable lengths: max. 15 m (shielded)
|
Mechanical data |
Degree of protection | IP65 |
Operating temperature | 0 °C to +55 °C Increased output at 0 °C to +45 °C |
Mounting position | Vertical wall mounting (vertical alignment of the cooling fins) |
Mounting dimensions (W x H x D) in mm (including terminal module) | 155 x 230 x 213 |
Weight | 4.0 kg |
Standards |
Compliance with standards | UL, cUL, CE, low voltage directive 73/23/EEC, EMC directive 89/336/EEC |