Pressure transmitter SITRANS LH100 (submersible sensor)
|
|
Mode of operation
|
|
|
Measuring principle
|
piezo-resistive
|
|
Input
|
|
|
Measured variable
|
Hydrostatic level
|
|
Measuring range
|
Max. permissible operating pressure
|
- 0 ... 4 mH2O (0 ... 12 ftH2O)
|
- 1.5 bar (21.8 psi) (corresponds to 15 mH2O (45 ftH2O))
|
- 0 ... 5 mH2O (0 ... 15 ftH2O)
|
- 1.5 bar (21.8 psi) (corresponds to 15 mH2O (45 ftH2O))
|
- 0 ... 6 mH2O (0 ... 18 ftH2O)
|
- 1.5 bar (21.8 psi) (corresponds to 15 mH2O (45 ftH2O))
|
- 0 ... 10 mH2O (0 ... 30 ftH2O)
|
- 3.0 bar (43.5 psi) (corresponds to 30 mH2O (90 ftH2O))
|
- 0 ... 20 mH2O (0 ... 60 ftH2O)
|
- 5.0 bar (72.5 psi) (corresponds to 50 mH2O (150 ftH2O))
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Output
|
|
|
Output signal
|
4 ... 20 mA
|
|
Measuring accuracy
|
According to IEC 60770-1
|
|
Error in measurement at limit setting including hysteresis and reproducibility
|
0.3% of full-scale value (typical)
|
|
Influence of ambient temperature
|
|
|
Zero and span
|
|
- 4 ... 6 mH2O (12 ... 18 ftH2O or 0.4…0.6 bar)
|
0.45 %/10 K of full-scale value
|
- > 6 mH2O ( > 18 ftH2O or > 0.6 bar)
|
0.3 %/10 K of full-scale value
|
|
Long-term stability
|
|
|
Zero and span
|
|
- 4 ... 6 mH2O (12 ... 18 ftH2O or 0.4…0.6 bar)
|
0.25% of full-scale value/year
|
- > 6 mH2O ( > 18 ftH2O or > 0.6 bar)
|
0.2 % of full-scale value/year
|
|
Rated conditions
|
|
|
Ambient conditions
|
|
|
|
-10 ... +80 °C (14 ... 176 °F)
|
|
|
-40 ... +80 °C (-40 ... +176 °F)
|
|
Degree of protection according to IEC 60529
|
IP68
|
|
Design
|
|
|
Weight
|
|
|
|
? 0.2 kg ( ? 0.44 lb)
|
|
|
0.025 kg/m (? 0.015 lb/ft)
|
|
Electrical connection
|
Cable with 3 conductors, vent pipe and integrated humidity filter
|
|
Material
|
|
|
|
Al2O3 ceramic, 96%
|
|
|
Stainless steel, mat. no. 1.4404/316L
|
|
|
FPM (standard)
EPDM (optional)
|
|
|
PE-HD (standard)
PE-LD (in the case of versions with EPDM seal, suitable for drinking water applications)
|
|
Auxiliary power
|
|
|
Terminal voltage on pressure transmitter UB
|
10 ... 33 V DC
10 ... 30 V DC for transmitter with intrinsic safety explosion protection
|
|
Certificates and approvals
|
|
|
Drinking water approval (ACS)
|
applied for
|
|
Drinking water approval (WRAS)
|
applied for
|
|
GOST
|
applied for
|
|
Underwriters Laboratories (UL)
|
applied for
|
|
The transmitter is not subject to the pressure equipment directive (PED 97/23/EC)
|
|
|
Explosion protection
|
|
|
|
IECEx SEV 14.0003 SEV 14 ATEX 0109
|
|
|
II 1 G Ex ia IIC T4 Ga
|