Application
- Measurements for boiler control in combustion plants
- Emission measurements in incineration plants
- Measurements in the automotive industry (test benches)
- Warning equipment
- Process gas concentrations in chemical plants
- Trace measurements in pure gas processes
- Environment protection
- MAC-value monitoring at place of work
- Quality monitoring
- Ex versions to analyze flammable and non-flammable gases or vapors for use in hazardous areas.
Special versions
- Special applications
Besides the standard combinations special applications concerning material of the gas path, material of the sample cells (e.g. titanium, Hastelloy C22) and sample components are also available on request.
- TUV version
TUV-approved versions are available for measurement of CO, NO and SO2 according to 13. BImSchV and TA Luft. Smallest TUV-approved and permitted measuring ranges:
- 1-component analyzer
CO: 0 to 50 mg/m3 NO: 0 to 100 mg/m3 SO2: 0 to 75 mg/m3 - 2-component analyzer (series connection)
CO: 0 to 75 mg/m3 NO: 0 to 200 mg/m3
Furthermore, the TUV-approved versions of the ULTRAMAT 6 comply with the requirements of EN 14956 and of QAL 1 according to EN 14181. Conformity of the analyzers with both standards is TUV-certified.
Determination of the analyzer drift according to EN 14181 (QAL 3) can be carried out manually or also with a PC using the SIPROM GA maintenance and servicing software. In addition, selected manufacturers of emission evaluation computers offer the possibility for downloading the drift data via the analyzer’s serial interface and to automatically record and process them in the evaluation computer.
|
|