Power cables for motors
MOTION-CONNECT power cableswithout brake cores for motors connected to Motor Modules

Connection method,
Motor
Module
end

Number of cores ? cross-section

Connector size,
motor end

Pre-assembled cable for 1FT/1FK motors

D max

Cable sold by the meter1)
for motors with terminal box

Weight
(without connector)

Smallest perm. bending radius2)

6FX5

6FX8

6FX5

6FX8

6FX5

6FX8

mm2

Order No.

mm (in)

mm (in)

Order No.

kg/m (lb/ft)

kg/m (lb/ft)

mm (in)

mm (in)

Connector3)

4 ? 1.5

1

6FX?002?5CS01?....

8.4 (0.33)

10.4 (0.41)

6FX?008?1BB11?....

0.12 (0.08)

0.16 (0.11)

155 (6.10)

100 (3.94)

1.5

6FX?002?5CS21?....

e. c.4)

6FX5002?5CS02?....

4 ? 2.5

1

6FX?002?5CS11?....

10.0 (0.39)

12.1 (0.48)

6FX?008?1BB21?....

0.21 (0.14)

0.23 (0.16)

180 (7.09)

120 (4.72)

1.5

6FX?002?5CS31?....

e. c.4)

6FX5002?5CS12?.....

4 ? 4

1.5

6FX?002?5CS41?....

11.4 (0.45)

13.2 (0.52)

6FX?008?1BB31?....

0.27 (0.18)

0.31 (0.21)

210 (8.27)

130 (5.12)

e. c.4)

6FX5002?5CS42?....

4 ? 6

1.5

6FX?002?5CS51?....

13.6 (0.54)

16.0 (0.63)

6FX?008?1BB41?....

0.37 (0.25)

0.42 (0.28)

245 (9.65)

170 (6.69)

e. c.4)

6FX5002?5CS52?....

4 ? 10

1.5

6FX?002?5CS61?...

20.0 (0.79)

19.4 (0.76)

6FX?008?1BB51?....

0.73 (0.49)

0.63 (0.42)

360 (14.17)

210 (6.69)

3

6FX?002?5CS13?....

e. c.4)

6FX5002?5CS62?....

Ring terminal ends

4 ? 6

1.5

6FX?002?5CS54?....

13.6 (0.54)

16.0 (0.63)

6FX?008?1BB41?....

0.37 (0.25)

0.42 (0.28)

245 (9.65)

170 (6.69)

4 ? 10

1.5

6FX?002?5CS64?....

20.0 (0.79)

19.4 (0.76)

6FX?008?1BB51?....

0.73 (0.49)

0.63 (0.42)

360 (14.17)

210 (6.69)

3

6FX?002?5CS14?....

4 ? 16

1.5

6FX8002?5CS24?....

24.2 (0.95)

23.6 (0.93)

6FX?008?1BB61?....

1.10 (0.74)

0.95 (0.64)

440 (17.32)

260 (10.24)

3

6FX?002?5CS23?....

Sold by the meter

4 ? 25

28.0 (1.10)

6FX5008?1BB25?....

1.62 (1.09)

505 (19.88)

4 ? 35

31.5 (1.24)

6FX5008?1BB35?....

1.93 (1.30)

570 (22.44)

4 ? 50

38.0 (1.50)

6FX5008?1BB50?....

3.04 (2.04)

685 (26.97)

4 ? 70

42.6 (1.68)

6FX5008?1BB70?....

3.96 (2.66)

770 (30.31)

4 ? 95

51.7 (2.04)

6FX5008?1BB05?....

5.55 (3.73)

935 (36.81)

4 ? 120

56.0 (2.20)

6FX5008?1BB12?....

6.69 (4.50)

1010 (39.76)

4 ? 150

63.0 (2.48)

6FX5008?1BB15?....

8.21 (5.52)

1135 (44.68)

4 ? 185

66.2 (2.61)

6FX5008?1BB18?....

9.82 (6.60)

1195 (47.05)

MOTION?CONNECT 500

       5

       5

MOTION?CONNECT 800

       8

       8

Length codes

                             ....

                            ....


1) Power cables of 1.5 mm2and 2.5 mm2 are supplied in coils or on disposable drums in lengths of 50 m, 100 m, 200 m and 500 m (164 ft, 328 ft, 656 ft, 1640 ft).
Power cables of ? 4 mm2 can be ordered to the meter in lengths of up to 100 m (328 ft) and in fixed lengths above 100 m (328 ft) on disposable drums.

2) Valid for routing in cable carrier.

3) For Motor Modules 3 … 30 A in Booksize format.

4) e. c. = exposed core ends; suitable for motors with terminal box.

MOTION-CONNECT power cableswith brake cores for motors connected to Motor Modules

Connection method,
Motor
Module
end

Number of cores ? cross-section

Connector size,
motor end

Pre-assembled cable for 1FT/1FK motors

D max

Cable sold by the meter1)
for motors with terminal box

Weight
(without connector)

Smallest perm. bending radius2)

6FX5

6FX8

6FX5

6FX8

6FX5

6FX8

mm2

Order No.

mm (in)

mm (in)

Order No.

kg/m (lb/ft)

kg/m (lb/ft)

mm (in)

mm (in)

Connector3)

4 ? 1.5 + 2 ? 1.5

0.5

6FX5002?5DA20?….

10.8 (0.43)

12.9 (0.51)

6FX?008?1BA11?....

0.22 (0.15)

0.25 (0.17)

195 (7.68)

125 (4.92)

1

6FX?002?5DS01?....

1.5

6FX?002?5DS21?....

4 ? 2.5 + 2 ? 1.5

1

6FX?002?5DS11?....

12.4 (0.49)

14.2 (0.56)

6FX?008?1BA21?....

0.25 (0.17)

0.31 (0.21)

225 (8.86)

140 (4.92)

1.5

6FX?002?5DS31?....

4 ? 4 + 2 ? 1.5

1.5

6FX?002?5DS41?....

14.0 (0.55)

15.3 (0.60)

6FX?008?1BA31?....

0.35 (0.24)

0.40 (0.27)

255 (10.04)

150 (5.91)

4 ? 6 + 2 ? 1.5

1.5

6FX?002?5DS51?....

16.1 (0.63)

17.8 (0.70)

6FX?008?1BA41?....

0.49 (0.33)

0.53 (0.36)

290 (11.42)

195 (7.68)

4 ? 10 + 2 ? 1.5

1.5

6FX?002?5DS61?....

21.7 (0.85)

20.8 (0.82)

6FX?008?1BA51?....

0.81 (0.54)

0.78 (0.52)

395 (15.55)

230 (9.06)

3

6FX?002?5DS13?....

Ring terminal ends

4 ? 6 + 2 ? 1.5

1.5

6FX?002?5DS54?....

16.1 (0.63)

17.8 (0.70)

6FX?008?1BA41?....

0.49 (0.33)

0.53 (0.36)

290 (11.42)

195 (7.68)

4 ? 10 + 2 ? 1.5

1.5

6FX?002?5DS64?....

21.7 (0.85)

20.8 (0.82)

6FX?008?1BA51?....

0.81 (0.54)

0.78 (0.52)

395 (15.55)

230 (9.06)

3

6FX?002?5DS14?....

4 ? 16 + 2 ? 1.5

3

6FX?002?5DS23?....

25.0 (0.98)

24.7 (0.97)

6FX?008?1BA61?....

1.12 (0.75)

1.05 (0.71)

450 (17.72)

275 (10.83)

Exposed core ends4)

4 ? 25 + 2 ? 1.5

3

6FX?002?5DG33?....

29.4 (1.16)

27.9 (1.10)

6FX?008?1BA25?....

1.62 (1.09)

1.51 (1.01)

530 (20.87)

325 (12.80)

4 ? 35 + 2 ? 1.5

3

6FX?002?5DG43?....

32.6 (1.28)

32.0 (1.26)

6FX?008?1BA35?....

2.06 (1.38)

2.00 (1.34)

590 (23.23)

380 (14.96)

4 ? 50 + 2 ? 1.5

3

6FX?002?5DG53?....

38.0 (1.50)

35.8 (1.41)

6FX?008?1BA50?....

3.04 (2.04)

2.66 (1.79)

685 (27.97)

420 (16.54)

MOTION?CONNECT 500

       5

       5

MOTION?CONNECT 800

       8

       8

Length codes

                             ....

                            ....


1) Power cables of 1.5 mm2and 2.5 mm2 are supplied in coils or on disposable drums in lengths of 50 m, 100 m, 200 m and 500 m (164 ft, 328 ft, 656 ft, 1640 ft).
Power cables of ? 4 mm2 can be ordered to the meter in lengths of up to 100 m (328 ft) and in fixed lengths above 100 m (328 ft) on disposable drums.

2) Valid for routing in cable carrier.

3) For Motor Modules 3 … 30 A in Booksize format.

4) Length of core ends: 300 mm (11.81 in). 4 M8 cable lugs, 1 M6 cable lug and 1 spring-loaded terminal are also included in the scope of supply of the cables.

MOTION-CONNECT power cableswithout brake cores for motors connected toPower Modules AC/AC units and Motor Modules in booksize compact format

Connection method,
Power
Module
end

Number of cores ? cross-section

Connector size,
motor end

Pre-assembled cable for 1FT/1FK motors

D max

Cable sold by the meter1)

Weight
(without connector)

Smallest perm. bending radius2)

6FX5

6FX8

6FX5

6FX8

6FX5

6FX8

mm2

Order No.

mm (in)

mm (in)

Order No.

kg/m (lb/ft)

kg/m (lb/ft)

mm (in)

mm (in)

Exposed core ends

4 ? 1.5

1

6FX?002?5CG01?....

8.4 (0.33)

10.4 (0.41)

6FX?008?1BB11?....

0.12 (0.08)

0.16 (0.11)

155 (6.10)

100 (3.94)

1.5

6FX?002?5CG21?....

4 ? 2.5

1

6FX?002?5CG11?....

10.0 (0.39)

12.1 (0.48)

6FX?008?1BB21?....

0.21 (0.14)

0.23 (0.15)

180 (7.09)

120 (4.72)

1.5

6FX?002?5CG31?....

4 ? 4

1.5

6FX?002?5CG41?....

11.4 (0.45)

13.2 (0.52)

6FX?008?1BB31?....

0.27 (0.18)

0.31 (0.21)

210 (8.27)

130 (5.12)

4 ? 6

1.5

6FX?002?5CG51?....

13.6 (0.54)

16.0 (0.63)

6FX?008?1BB41?....

0.37 (0.25)

0.42 (0.28)

245 (9.65)

170 (6.69)

4 ? 10

1.5

6FX?002?5CG61?....

20.0 (0.79)

19.4 (0.76)

6FX?008?1BB51?....

0.73 (0.49)

0.63 (0.42)

360 (14.17)

210 (8.27)

3

6FX?002?5CG13?....

4 ? 16

3

6FX?002?5CG23?....

24.2 (0.95)

23.6 (0.93)

6FX5008?1BB61?....

1.10 (0.74)

0.95 (0.64)

440 (17.32)

260 (10.24)

MOTION?CONNECT 500

       5

       5

MOTION?CONNECT 800

       8

       8

Length codes

                             ....

                            ....


1) Power cables of 1.5 mm2and 2.5 mm2 are supplied in coils or on disposable drums in lengths of 50 m, 100 m, 200 m and 500 m (164 ft, 328 ft, 656 ft, 1640 ft).
Power cables of ? 4 mm2 can be ordered to the meter in lengths of up to 100 m (328 ft) and in fixed lengths above 100 m (328 ft) on disposable drums.

2) Valid for routing in cable carrier.

MOTION-CONNECT power cableswith brake cores for motors connected to Power Modules AC/AC units and Motor Modules in booksize compact format

Connection method,
Power
Module
end

Number of cores ? cross-section

Connector size,
motor end

Pre-assembled cable for 1FT/1FK motors

D max

Cable sold by the meter 1)

Weight
(without connector)

Smallest perm. bending radius2)

6FX5

6FX8

6FX5

6FX8

6FX5

6FX8

mm2

Order No.

mm (in)

mm (in)

Order No.

kg/m (lb/ft)

kg/m (lb/ft)

mm (in)

mm (in)

Exposed core ends

4 ? 1.5 + 2 ? 1.5

0.5

6FX5002?5DA30?….

10.8 (0.43)

6FX5008?1BA11?....

0.22 (0.15)

195 (7.68)

1

6FX?002?5DG01?....

10.8 (0.43)

12.9 (0.51)

6FX?008?1BA11?....

0.22 (0.15)

0.25 (0.17)

195 (7.68)

125 (4.92)

1.5

6FX?002?5DG21?....

4 ? 2.5 + 2 ? 1.5

1

6FX?002?5DG11?....

12.4 (0.49)

14.2 (0.56)

6FX?008?1BA21?....

0.25 (0.17)

0.31 (0.21)

225 (8.86)

140 (5.51)

1.5

6FX?002?5DG31?....

4 ? 4 + 2 ? 1.5

1.5

6FX?002?5DG41?....

14.0 (0.55)

15.3 (0.60)

6FX?008?1BA31?....

0.35 (0.34)

0.40 (0.27)

255 (10.04)

150 (5.91)

4 ? 6 + 2 ? 1.5

1.5

6FX?002?5DG51?....

16.1 (0.63)

17.8 (0.70)

6FX?008?1BA41?....

0.49 (0.33)

0.53 (0.36)

290 (11.42)

195 (7.68)

4 ? 10 + 2 ? 1.5

1.5

6FX?002?5DG61?....

21.7 (0.85)

20.8 (0.82)

6FX?008?1BA51?....

0.81 (0.54)

0.78 (0.52)

395 (15.55)

230 (9.06)

3

6FX?002?5DG13?....

4 ? 16 + 2 ? 1.5

3

6FX?002?5DG23?....

25.0 (0.98)

24.7 (0.60)

6FX?008?1BA61?....

1.12 (0.75)

1.05 (0.71)

450 (17.72)

275 (10.83)

4 ? 25 + 2 ? 1.5

3

6FX?002?5DG33?....

29.4 (1.16)

27.9 (1.10)

6FX?008?1BA25?....

1.62 (1.09)

1.51 (1.01)

530 (20.87)

325 (12.80)

4 ? 35 + 2 ? 1.5

3

6FX?002?5DG43?....

32.6 (1.28)

32.0 (1.26)

6FX?008?1BA35?....

2.06 (1.38)

2.00 (1.34)

590 (23.23)

380 (14.96)

4 ? 50 + 2 ? 1.5

3

6FX?002?5DG53?....

38.0 (1.50)

35.8 (1.41)

6FX?008?1BA50?....

3.04 (2.04)

2.66 (1.79)

685 (26.97)

420 (16.54)

MOTION?CONNECT 500

       5

       5

MOTION?CONNECT 800

       8

       8

Length codes

                             ....

                            ....


1) Power cables of 1.5 mm2and 2.5 mm2 are supplied in coils or on disposable drums in lengths of 50 m, 100 m, 200 m and 500 m (164 ft, 328 ft, 656 ft, 1640 ft).
Power cables of ? 4 mm2 can be ordered to the meter in lengths of up to 100 m (328 ft) and in fixed lengths above 100 m (328 ft) on disposable drums.

2) Valid for routing in cable carrier.


Каталог оборудования

Приводная техника

Двигатели переменного тока

Двигатели постоянного тока

Децентрализованная приводная техника

Преобразователи

Стандартные преобразователи

MICROMASTER

Преобразователи частоты SINAMICS G110

SINAMICS G110 chassis units

SINAMICS G110 chassis units

SINAMICS G110 chassis units

SINAMICS G120 формат шасси

Преобразователи SINAMICS G130

SINAMICS G150 Drive converter cabinet units

Line-side power components

Tools and configuration

Преобразователь частоты SINAMICS G150 шкафного исполнения

SINAMICS S120

Системный обзор

Технические данные

Подключение

Компоненты

Кабели и штекеры MOTION-CONNECT

Силовые кабели

Power cables for motors

...взрывозащищенных серии 1FS6

Сигнальные кабели

Сигнальные кабели

Аксессуары для силовых/сигнальных кабелей

Коды длин

Safety Integrated

SINAMICS S120 встраиваемого исполнения

Преобразователи SINAMICS S150

Преобразователи SIMODRIVE

Преобразователь частоты SIMOVERT MASTERDRIVES

Преобразователи постоянного тока

Инструментальное программное обеспечение

Дополнительные компоненты

Техника автоматизации

Коммуникации и сети

Низковольтная коммутационная техника

Электроустановочная техника

Специализированные сенсоры

Блоки питания

Технология безопасности

Системные решения и продукты для отраслей

Сервис

Автоматизация процесса

... и все, что Вам еще необходимо


  © ООО "СК ЭНЕРГО" 2007-2022
  (4872) 700-366  skenergo@mail.ru
Яндекс.Метрика