Basic Functions |
STO | | SBC (if activated) | – | No | No | - CU240E-2
- CU240E-2 DP
- CU240E-2 PN
- CU240E-2 F
- CU240E-2 DP-F
- CU240E-2 PN-F
- CU250S-2
- CU250S-2 CAN
- CU250S-2 DP
- CU250S-2 PN
|
SS1 time-controlled | | STO and SBC (if activated) following expiry of the parameterized delay time or if the speed falls below the minimum speed limit | STO | No | No | - CU240E-2 F
- CU240E-2 DP-F
- CU240E-2 PN-F
- CU250S-2
- CU250S-2 CAN
- CU250S-2 DP
- CU250S-2 PN
|
SBC | - With STO (immediately or following expiry of the delay time with SS1)
| – | – | No | No | - CU250S-2
- CU250S-2 CAN
- CU250S-2 DP
- CU250S-2 PN
|
Extended Functions |
SS1 with SBR/SAM | | Safe Acceleration Monitor (SAM) or Safe Brake Ramp (SBR) during braking. STO and SBC (if activated) following expiry of the parameterized delay time or if the speed falls below the minimum speed limit | STO | No | No | - CU240E-2 F
- CU240E-2 DP-F
- CU240E-2 PN-F
|
Yes | - CU250S-2
- CU250S-2 CAN
- CU250S-2 DP
- CU250S-2 PN
|
SLS | | – | STO, SS1 (can be parameterized) | No | No | - CU240E-2 F
- CU240E-2 DP-F
- CU240E-2 PN-F
|
Yes | - CU250S-2
- CU250S-2 CAN
- CU250S-2 DP
- CU250S-2 PN
|
SDI | | – | STO, SS1 (can be parameterized) | No | No | - CU240E-2 F
- CU240E-2 DP-F
- CU240E-2 PN-F
|
Yes | - CU250S-2
- CU250S-2 CAN
- CU250S-2 DP
- CU250S-2 PN
|
SSM | - Always active,
if configured
| – | Signals that the speed has fallen below a specified value | No | No | - CU240E-2 DP-F 1)
- CU240E-2 PN-F 1)
|
Yes | - CU250S-2
- CU250S-2 CAN
- CU250S-2 DP
- CU250S-2 PN
|