The PM250D Power Modules are generally prepared for Safety Integrated. In conjunction with a standard Control Unit, the drive provides the safety function STO. In conjunction with a fail-safe Control Unit, the drive can be turned into a Safety Integrated Drive with comprehensive safety functions. The Safety Integrated functions are fully integrated in the drive system. They can be activated via fail-safe digital inputs on the Control Unit or via PROFINET or PROFIBUS with PROFIsafe. The Safety Integrated functions are implemented electronically and therefore offer short response times compared to solutions with externally implemented monitoring functions. Safety Integrated encoderless The safety functions do not require a motor encoder; the implementation effort is minimal. Existing machines in particular can be updated with integrated safety technology without the need to change the motor or mechanical system. The STO function can be used without any restrictions for all applications. The SS1, SLS, SSM and SDI functions are only permissible for applications where the load can never cause acceleration. An encoder that is used for the purposes of motor control has no significance for the safety functions here. Control Units The availability of Safety Integrated functions depends on the type of Control Unit. Standard Control Units and fail-safe Control Units are available. All standard Control Units have STO. The fail-safe Control Units offer Extended Functions (SLS, SDI, SSM) in addition to the Basic Functions (STO, SS1). |
| Каталог 2018 | Каталог 2017 | Каталог 2016 | Каталог 2015 | Каталог 2014 | Каталог 2013 | Каталог 2012 | Сертификат | Контакты | Карта сайта | Поиск |