Article No. | | 6FX2001-3.... | 6FX2001-2.... |
Product name | | Motion control encoder | Motion control encoder |
Product designation | | Incremental encoder with sin/cos 1 Vpp | Incremental encoder with RS422 (TTL) |
Operating voltage DC Up on encoder | V | 5 ± 10 % | 5 ± 10 % or 10 ... 30 |
Limit frequence typical | kHz | ≥ 180 (- 3 dB) ≥ 450 (- 6 dB) | – |
Scanning frequenz maximum | kHz | – | 300 |
No-load current consumption maximum | mA | 150 | 150 |
Resolution maximum | S/R | 2500 | 5000 |
Signal level | | Sinusoidal 1 Vpp | RS422 (TTL) |
Outputs protected against short-circuit to 0 V | | Yes Briefly | Yes |
Switching time (10 ... 90 %) rise/fall time t+/t- (for 1 m (3.28 ft) cable and recommeded input circuit) | ns | – | ≤ 50 |
Phase angle signal A to B Edge spacing | Degrees | 90 ± 10 | 90 |
| µs | – | ≥ 0.45 |
Cable length to downstream electronics, maximum1) | m (ft) | 150 (492) | 100 (328) without fault signal 50 (164) with fault signal |
Accuracy | arcsec | ± 18 mech. Г— 3600/PPR count z | ± 18 mech. Г— 3600/PPR count z |
LED failure monitoring | | – | High-resistance driver |
Maximum mechanical speed | rpm | 12000 | 12000 |
Starting torque at 20 °C (68 °F) | Nm (lbf-ft) | ≤ 0.01 (0.01) | ≤ 0.01 (0.01) |
Shaft loading capacity | | | |
| | | |
| N (lbf) | 40 (8.99) | 40 (8.99) |
- Radial at shaft extension
| N (lbf) | 60 (13.5) | 60 (13.5) |
| | | |
| N (lbf) | 10 (2.25) | 10 (2.25) |
- Radial at shaft extension
| N (lbf) | 20 (4.50) | 20 (4.50) |
Shaft diameter | | | |
| mm (in) | 6 (0.24) | 6 (0.24) |
| mm (in) | 10 (0.39) | 10 (0.39) |
Shaft length | | | |
| mm (in) | 10 (0.39) | 10 (0.39) |
| mm (in) | 20 (0.79) | 20 (0.79) |
Angular acceleration maximum | rad/s2 | 105 | 105 |
Moment of inertia of rotor | kgm2 (lbf‑in‑s2) | ≤ 2.9 × 10-6 (2.57 × 10-5 ) | ≤ 2.9 × 10-6 (2.57 × 10-5 ) |
Vibration (55 ... 2000 Hz) according to EN 60068‑2‑6 | m/s2 (ft/s2) | ≤ 300 (984) | ≤ 300 (984) |
Shock according to EN 60068‑2‑27 | | | |
| m/s2 (ft/s2) | ≤ 2000 (6562) | ≤ 2000 (6562) |
Degree of protection | | | |
| | IP67 | IP67 |
| | IP64 | IP64 |
Ambient temperature, during | | | |
Operation | | | |
- Flange outlet or fixed cable
| | | |
| °C (°F) | -40 ... +100 (-40 ... +212) | -40 ... +100 (-40 ... +212) |
| °C (°F) | – | -40 ... +70 (-40 ... +158) |
| | | |
| °C (°F) | -10 ... +100 (14 ... 212) | -10 ... +100 (14 ... 212) |
| °C (°F) | – | -10 ... +70 (14 ... 158) |
Net weight | kg (lb) | 0.3 (0.66) | 0.3 (0.66) |
EMC | | EMC Directive 2004/108/EG and regulations for EMC directives (applicable basic standards) | EMC Directive 2004/108/EG and regulations for EMC directives (applicable basic standards) |
Certificate of suitability | | CE, CSA, UL | CE, CSA, UL |