Cooling | Forced ventilation | Water cooling |
- Cooling water pressure at inlet, max.
| – | 6 bar |
| | | Cooling water flow rate | Connection thread at NDE1) |
| – | 6 l/min (1.59 US gallons/min.) | G 1/8“ |
| – | 8 l/min (2.11 US gallons/min.) | G 1/4“ |
| – | 12 l/min (3.17 US gallons/min.) | G 3/8“ |
| – | 15 l/min (3.96 US gallons/min.) | G 1/2“ |
| – | 15 l/min (3.96 US gallons/min.) | G 3/8“ |
| – | 20 l/min (5.28 US gallons/min.) | G 3/8“ |
| – | 35 l/min (9.25 US gallons/min.) | G 1/2“ |
Ambient temperature, permissible | -15 ... +40 °C (5 ... 104 °F) |
Coolant inlet temperature | – | < 30 °C (86 °F) |
Temperature monitoring | Temperature sensor in stator winding |
| Additional temperature sensor as reserve |
Stator winding insulation in accordance with EN 60034-1 (IEC 60034-1) | For an ambient temperature of up to 40 °C (104 °F) Temperature class 180 (H) | For a coolant inlet temperature up to 30 °C (86 °F) Temperature class 180 (H) |
Fan supply voltage | | |
| 230 V 1 AC 50/60 Hz, 265 V 1 AC 60 Hz | – |
| 400 V 3 AC 50/60 Hz, 480 V 3 AC 60 Hz | – |
| 200 V ... 277 V 1 AC, 50/60 Hz (EC fan) 400 V 3 AC 50/60 Hz, 480 V 3 AC 60 Hz optional (L75) | – |
| 400 V 3 AC 50/60 Hz, 480 V 3 AC 60 Hz | – |
Encoder system, built-in | Without DRIVE-CLiQ interface or with DRIVE-CLiQ interface |
Sound pressure level LpA (1 m) in accordance with EN ISO 1680 max. tolerance +3 dB | | |
| 70 dB at rated pulse frequency 4 kHz and speed range up to 5000 rpm | 68 dB at rated pulse frequency 4 kHz and speed range up to 5000 rpm |
| 73 dB at rated pulse frequency 4 kHz and speed range up to 5000 rpm | 69 dB at rated pulse frequency 4 kHz and speed range up to 5000 rpm |
| 73 dB at a rated pulse frequency of 2 kHz and a speed range: Forced ventilation (IP55) - 1PH818 up to 5000 rpm
- 1PH822 up to 3500 rpm
| 70 dB at rated pulse frequency 2 kHz and speed ranges: - 1PH818 up to 5000 rpm
- 1PH822 up to 3500 rpm
|
| 74 dB at rated pulse frequency 2 kHz and speed range up to 3300 rpm | 72 dB at rated pulse frequency 2 kHz and speed range up to 3300 rpm |
Connection | |
| Power connector or terminal box |
- 1PH816/1PH818/1PH822/1PH828
| Terminal box | Terminal box |
| | |
| Power connector | – |
| Power connector or terminal box | – |
- 1PH816/1PH818/1PH822/1PH828
| Terminal box | – |
| Connector for signals (without mating connector) or DRIVE-CLiQ |
Vibration severity | In accordance with Siemens/EN 60034-14 (IEC 60034-14) |
Shaft and flange accuracy in accordance with DIN 42955 (IEC 60072-1)2) | Tolerance R |
Degree of protection in accordance with EN 60034-5 (IEC 60034-5) | | |
- 1PH808/1PH810/1PH813/1PH816
| IP55 | IP65 |
| IP55 | IP55 |
| IP55, option IP74: IP65 3) | – |
Rating plate | 1 unit attached to motor 1 unit supplied loose in terminal box |
Paint finish | Anthracite RAL 7016 |
Certificate of suitability | cURus |