Cooling
|
Forced ventilation
|
Water cooling
|
- Cooling water pressure at inlet, max.
|
?
|
6 bar
|
- Cooling water flow volume
|
|
|
|
|
?
|
6 l/min (1.59 US gallons/min.)
|
|
|
?
|
8 l/min (2.11 US gallons/min.)
|
|
|
?
|
12 l/min (3.17 US gallons/min.)
|
|
|
|
15 l/min (3.96 US gallons/min.)
|
|
|
?
|
15 l/min (3.96 US gallons/min.)
|
|
|
?
|
20 l/min (5.28 US gallons/min.)
|
|
|
?
|
35 l/min (9.25 US gallons/min.)
|
- Connecting thread at NDE1)
|
?
|
|
|
|
?
|
G 1/8“
|
|
|
?
|
G 1/4“
|
|
|
?
|
G 3/8“
|
|
|
?
|
G 1/2“
|
|
|
?
|
G 3/8“
|
|
|
?
|
G 3/8“
|
|
|
?
|
G 1/2“
|
|
Ambient temperature, permissible
|
-15 ... +40 °C (5 ... 104 °F)
|
|
Coolant inlet temperature
|
?
|
< 30 °C (86 °F)
|
|
Temperature monitoring
|
KTY 84 temperature sensor in the stator winding
|
|
|
Additional KTY 84 as spare
|
|
Insulation of the stator winding in accordance with EN 60034-1 (IEC 60034-1)
|
For an ambient temperature of up to 40 °C (104 °F) Temperature class 180 (H)
|
For a coolant inlet temperature of up to 30 °C (86 °F) Temperature class 180 (H)
|
|
Motor fan ratings
|
|
?
|
- 1PH808
- 1PH810 bis 1PH816
- 1PH818/1PH822
- 1PH828
|
230 V 1 AC 50/60 Hz, 265 V 1 AC 60 Hz
400 V 3 AC 50/60 Hz, 480 V 3 AC 60 Hz
200 V ... 277 V 1 AC 50/60 Hz (EC fan)
400 V 3 AC 50/60 Hz, 480 V 3 AC 60 Hz
|
-
-
-
-
|
|
Encoder system, built-in
|
Without DRIVE-CLiQ interface or with DRIVE-CLiQ interface
|
|
Sound pressure level
L
pA
(1 m)
in accordance with DIN EN ISO 1680
Tolerance + 3 dB
|
Rated pulse frequency 4 kHz
|
Rated pulse frequency 4 kHz/2 kHz2)
|
|
|
70 dB at a rated pulse frequency of 4 kHz and a speed range up to 5000 rpm
|
68 dB at a rated pulse frequency of 4 kHz and a speed range up to 5000 rpm
|
|
|
73 dB at a rated pulse frequency of 4 kHz and a speed range up to 5000 rpm
|
69 dB at a rated pulse frequency of 4 kHz and a speed range up to 5000 rpm
|
|
|
73 dB at a rated pulse frequency of 2 kHz and a speed range:
Forced ventilation (IP55)
1PH818 up to 5000 rpm
1PH822 up to 4500 rpm
|
70 dB at a rated pulse frequency of 2 kHz or 4 kHz and a speed range:
1PH818 up to 5000 rpm
1PH822 up to 4500 rpm
|
|
|
74 dB at a rated pulse frequency of 2 kHz and a speed range up to 3300 rpm:
Forced ventilation (IP55)
1PH828 up to 3300 rpm
|
72 dB at a rated pulse frequency of 2 kHz and a speed range up to 3300 rpm
|
|
Connection
|
|
|
|
Power connector or terminal box
|
- 1PH816/1PH818/1PH822/1PH828
|
Terminal box
|
Terminal box
|
|
|
|
|
|
|
Power connector
|
?
|
|
|
Power connector or terminal box
|
?
|
- 1PH816/1PH818/1PH822/1PH828
|
Terminal box
|
-
|
|
|
Connector for signals (without mating connector) or DRIVE-CLiQ
|
|
Vibration severity
|
In accordance with Siemens/EN 60034-14 (IEC 60034-14)
|
|
Shaft and flange accuracy in accordance with DIN 42955 (IEC 60072-1)2)
|
Tolerance R
|
|
Degree of protection in accordance with EN 60034-5 (IEC 60034-5)
|
|
|
- 1PH808/1PH810/1PH813/1PH816
|
IP55
|
IP65
|
|
|
IP55
|
IP55
|
|
|
IP55, option IP74: IP65
|
?
|
|
Rating plate
|
1 unit attached to motor 1 unit supplied loose in terminal box
|
|
Paint finish
|
Anthracite RAL 7016
|
|
Approvals, according to
|
cURus
|