Article No. | | 6FX2001-3.... | 6FX2001-2.... | 6FX2001-4...0 |
Product name | | Motion Control encoder | Motion Control encoder | Motion Control encoder |
Product designation | | Incremental encoder with sin/cos 1 Vpp | Incremental encoder with RS422 (TTL) | Incremental encoder with HTL |
Operating voltage DC Vp on encoder | V | 5 ± 10 % | 5 ± 10 % or 10 ... 30 | 10 ... 30 |
Limit frequency, typical | kHz | ≥ 180 (- 3 dB) ≥ 450 (- 6 dB) | – | – |
Scanning frequency, maximum | kHz | – | 300 | 300 |
No-load current consumption, maximum | mA | 150 | 150 | 150 |
Resolution, maximum | S/R | 2500 | 5000 | 2500 |
Signal level | | Sinusoidal 1 Vpp | RS422 (TTL) | VH ≥ 21 V with IH = 20 mA at 24 V VL ≤ 2.8 V with IL = 20 mA at 24 V |
Outputs protected against short-circuit to 0 V | | Yes Briefly | Yes | Yes Briefly |
Switching time (10 ... 90 %) rise/fall time t+/t- (for 1 m (3.28 ft) cable and recommended input circuit) | ns | – | ≤ 50 | ≤ 200 |
Phase angle, signal A to B Edge spacing | Degrees | 90 ± 10 | 90 | 90 |
| µs | – | ≥ 0.45 | ≥ 0.45 |
Cable length to downstream electronics, maximum1) | m (ft) | 150 (492) | 100 (328) without fault signal 50 (164) with fault signal | 300 (984) |
Accuracy | arcsec | ± 18 mech. Г— 3600/PPR count z | ± 18 mech. Г— 3600/PPR count z | ± 18 mech. Г— 3600/PPR count z |
LED failure monitoring | | – | High-resistance driver | High-resistance driver |
Maximum mechanical speed | rpm | 12000 | 12000 | 12000 |
Starting torque at 20 °C (68 °F) | Nm (lbf-ft) | ≤ 0.01 (0.01) | ≤ 0.01 (0.01) | ≤ 0.01 (0.01) |
Shaft loading capacity | | | | |
| | | | |
| N (lbf) | 40 (8.99) | 40 (8.99) | 40 (8.99) |
- Radial at shaft extension
| N (lbf) | 60 (13.5) | 60 (13.5) | 60 (13.5) |
| | | | |
| N (lbf) | 10 (2.25) | 10 (2.25) | 10 (2.25) |
- Radial at shaft extension
| N (lbf) | 20 (4.50) | 20 (4.50) | 20 (4.50) |
Shaft diameter | | | | |
| mm (in) | 6 (0.24) | 6 (0.24) | 6 (0.24) |
| mm (in) | 10 (0.39) | 10 (0.39) | 10 (0.39) |
Shaft length | | | | |
| mm (in) | 10 (0.39) | 10 (0.39) | 10 (0.39) |
| mm (in) | 20 (0.79) | 20 (0.79) | 20 (0.79) |
Angular acceleration, maximum | rad/s2 | 105 | 105 | 105 |
Moment of inertia of rotor | kgm2 (lbf-in-s2) | ≤ 2.9 × 10-6 (2.57 × 10-5) | ≤ 2.9 × 10-6 (2.57 × 10-5) | ≤ 2.9 × 10-6 (2.57 × 10-5) |
Vibration (55 ... 2000 Hz) according to EN 60068‑2‑6 | m/s2 (ft/s2) | ≤ 300 (984) | ≤ 300 (984) | ≤ 300 (984) |
Shock according to EN 60068‑2‑27 | | | | |
| m/s2 (ft/s2) | ≤ 2000 (6562) | ≤ 2000 (6562) | ≤ 2000 (6562) |
Degree of protection | | | | |
| | IP67 | IP67 | IP67 |
| | IP64 | IP64 | IP64 |
Ambient temperature, during | | | | |
Operation | | | | |
- Flange outlet or fixed cable
| | | | |
| °C (°F) | -40 ... +100 (-40 ... +212) | -40 ... +100 (-40 ... +212) | -40 ... +100 (-40 ... +212) |
| °C (°F) | – | -40 ... +70 (-40 ... +158) | – |
| | | | |
| °C (°F) | -10 ... +100 (+14 ... +212) | -10 ... +100 (+14 ... +212) | -10 ... +100 (+14 ... +212) |
| °C (°F) | – | -10 ... +70 | – |
Net weight | kg (lb) | 0.3 (0.66) | 0.3 (0.66) | 0.3 (0.66) |
EMC | | EMC Directive 2014/30/EC and regulations of EMC directives (applicable basic standards) | EMC Directive 2014/30/EC and regulations of EMC directives (applicable basic standards) | EMC Directive 2014/30/EC and regulations of EMC directives (applicable basic standards) |
Certificate of suitability | | CE, CSA, UL | CE, CSA, UL | CE, CSA, UL |