| | 6FX2001?3.... | 6FX2001?2.... | 6FX2001?4...0 | 6FX2001?2UK00 |
Operating voltage DC Vp on encoder | V | 5 ± 10 % | 5 ± 10 % or 10 ... 30 | 10 ... 30 | 5 ± 5 % |
Limit frequency, typ. | kHz | ? 100 (-3 dB) ? 200 (-6 dB) | – | – | – |
Scanning frequency, max. | kHz | – | 300 | 300 | Track 1: 160 Track 2: 1000 |
No?load current consumption, max. | mA | 150 | 150 | 150 | Track 1: 150 Track 2: 150 |
Signal level | | Sinusoidal 1 Vpp | RS422 (TTL) | VH ? 21 V at IH = 20 mA at 24 V VL ? 2.8 V at IL = 20 mA at 24 V | RS422 (TTL) |
Outputs protected against short-circuit to 0 V | | Yes | Yes | Yes | Yes |
Switching time (10 ... 90%) rise/fall time t+/t- (1 m (3.28 ft) cable and recommended input circuit) | ns | – | ? 50 | ? 200 | ? 100 |
Phase angle, signal A to B Edge spacing, min. | Degrees | 90 ± 10 | 90 | 90 | 90 |
| µs | – | – | – | Track 1: ? 0.8 |
| µs | – | ? 0.45 | ? 0.45 | – |
| µs | – | – | – | Track 2: ? 0.125 |
Cable length to downstream electronics, max.1) | M (ft) | 150 (492) | 100 (328) | 300 (984) | Up to 500 kHz: 100 (328) Up to 1 MHz: 50 (164) |
LED failure monitoring | | – | High?resistance driver | High?resistance driver | – |
Resolution, max. | S/R | 2500 | 5000 | 2500 | Track 1: 1024 Track 2: 9000 |
Accuracy | arcsec | ± 18 mech. ? 3600/PPR count z | ± 18 mech. ? 3600/PPR count z | ± 18 mech. ? 3600/PPR count z | Track 1: ± 63 Track 2: ± 12 |
Speed, max. | | | | | |
| rpm | (18 ? 106 rpm)/PPR count (at -6 dB) | (18 ? 106 rpm)/PPR count | (18 ? 106 rpm)/PPR count | Track 1: 9000 Track 2: 6500 |
| rpm | 12000 | 12000 | 12000 | 12000 |
Friction torque (at 20 °C) (68 °F) | Nm (lbf?in) | ? 0.01 (0.09) | ? 0.01 (0.09) | ? 0.01 (0.09) | ? 0.01 (0.09) |
Starting torque (at 20 °C) (68 °F) | Nm (lbf?in) | ? 0.01 (0.09) | ? 0.01 (0.09) | ? 0.01 (0.09) | ? 0.01 (0.09) |
Shaft loading capacity | | | | | |
| | | | | |
| N (lbf) | 40 (8.99) | 40 (8.99) | 40 (8.99) | 10 (2.25) |
- Radial at shaft extension
| N (lbf) | 60 (13.5) | 60 (13.5) | 60 (13.5) | 20 (4.50) |
| | | | | |
| N (lbf) | 10 (2.25) | 10 (2.25) | 10 (2.25) | – |
- Radial at shaft extension
| N (lbf) | 20 (4.50) | 20 (4.50) | 20 (4.50) | – |
Shaft diameter | | | | | |
| mm (in) | 6 (0.24) | 6 (0.24) | 6 (0.24) | 6 (0.24) |
| mm (in) | 10 (0.39) | 10 (0.39) | 10 (0.39) | – |
Shaft length | | | | | |
| mm (in) | 10 (0.39) | 10 (0.39) | 10 (0.39) | 15 (0.59) |
| mm (in) | 20 (0.79) | 20 (0.79) | 20 (0.79) | – |
Angular acceleration, max. | rad/s2 | 105 | 105 | 105 | 105 |
Moment of inertia of rotor | kgm2 (lbf?in?s2) | 1.45 ? 10-6 (12.8 ? 10-6) | 1.45 ? 10-6 (12.8 ? 10-6) | 1.45 ? 10-6 (12.8 ? 10-6) | 20 ? 10-6 (177? 10-6) |
Vibration (55 ... 2000 Hz) acc. to EN 60068?2?6 | m/s2 (ft/s2) | ? 300 (984) | ? 300 (984) | ? 300 (984) | ? 100 (328) |
Shock acc. to EN 60068?2?27 | | | | | |
| m/s2 (ft/s2) | ? 2000 (6562) | ? 2000 (6562) | ? 2000 (6562) | – |
| m/s2 (ft/s2) | ? 1000 (3281) | ? 1000 (3281) | ? 1000 (3281) | ? 1000 (3281) |
Degree of protection acc. to EN 60529 (IEC 60529) | | | | | |
| | IP67 | IP67 | IP67 | IP67 |
| | IP64 | IP64 | IP64 | IP64 |
Ambient temperature | | | | | |
Operation | | | | | |
- Flange outlet or fixed cable
| | | | | |
| °C (°F) | ?40 ... +100 (?40 … +212) | ?40 ... +100 (?40 … +212) | ?40 ... +100 (?40 … +212) | ?10 ... +70 (+14 … +158) |
| °C (°F) | – | ?40 ... +70 (?40 … +158) | – | – |
| | | | | |
| °C (°F) | ?10 ... +100 (+14 … +212) | ?10 ... +100 (+14 … +212) | ?10 ... +100 (+14 … +212) | ?10 ... +70 (+14 … +158) |
| °C (°F) | – | ?10 ... +70 (+14 … +158) | – | – |
Weight, approx. | kg (lb) | 0.3 (0.66) | 0.3 (0.66) | 0.3 (0.66) | 0.7 (1.54) |
EMC | Tested in accordance with the guidelines for electromagnetic compatibility 89/336/EEC and the regulations of the EMC guidelines (generic standards) |
Approvals, according to | | CE, cULus | CE, cULus | CE, cULus | CE, cULus |