The AOP30 Advanced Operator Panel is an optional input/output device for SINAMICS DC MASTER converters. It can be separately ordered. The operator panel is only designed for installation outside the converter (e.g. in a cabinet door up to 4 mm thick), installation cut-out 141.5 Г— 197.5 mm. It sets itself apart as a result of the following properties:
The AOP30 communicates with the SINAMICS DC MASTER drive via the serial RS485 interface. The AOP30 can communicate with the Standard CUD as well as with the Advanced CUD of the SINAMICS DC MASTER. A 24 V power supply is required to operate the AOP30. For a maximum cable length of 50 m, this can be taken from the CUD of the SINAMICS DC MASTER. An external power supply must be used for cable lengths greater than 50 m. Assignment of the RS485 cable with a 24 V power supply from the CUD – max. cable length 50 m Assignment of the RS485 cable when using two CUDs (24 V power supply from one CUD) – max. cable length 50 m Assignment of the RS485 cable when supplying the AOP30 from an external 24 V DC source – max. cable length 200 m Assignment of the RS232 cable for connecting to an AC SINAMICS unit (not for SINAMICS DC MASTER!) |