Line voltage 380 ... 480 V 3 AC | Basic Line Modules |
|---|
| 6SL3730-1TE34-2AA3 | 6SL3730-1TE35-3AA3 | 6SL3730-1TE38-2AA3 | 6SL3730-1TE41-2AA3 | 6SL3730-1TE41-5AA3 | 6SL3730-1TE41-8AA3 |
|---|
For a parallel circuit configuration, mounted to the right of the Line Connection Module | | | | 6SL3730-1TE41-2BA3 | 6SL3730-1TE41-5BA3 | 6SL3730-1TE41-8BA3 |
|---|
For a parallel circuit configuration, mounted to the left of the Line Connection Module | | | | 6SL3730-1TE41-2BC3 | 6SL3730-1TE41-5BC3 | 6SL3730-1TE41-8BC3 |
|---|
Rated power | | | | | | | | - At Irated DC (50 Hz 400 V)
| kW | 200 | 250 | 400 | 560 | 710 | 900 | | kW | 160 | 200 | 315 | 450 | 560 | 705 | - At Irated DC (60 Hz 460 V)
| hp | 305 | 385 | 615 | 860 | 1090 | 1390 | | hp | 245 | 305 | 485 | 690 | 860 | 1090 | DC link current | | | | | | | | | A | 420 | 530 | 820 | 1200 | 1500 | 1880 | - Base-load current IH DC1)
| A | 328 | 413 | 640 | 936 | 1170 | 1467 | | A | 630 | 795 | 1230 | 1800 | 2250 | 2820 | Input current | | | | | | | | | A | 365 | 460 | 710 | 1010 | 1265 | 1630 | | A | 547 | 690 | 1065 | 1515 | 1897 | 2380 | Current demand | | | | | | | | - 24 V DC auxiliary power supply
| A | 1.1 | 1.1 | 1.1 | 1.1 | 1.1 | 1.1 | | A | Internal | Internal | Internal | Internal | Internal | Internal | DC link capacitance | | | | | | | | | μF | 7200 | 9600 | 14600 | 23200 | 29000 | 34800 | | μF | 57600 | 76800 | 116800 | 185600 | 232000 | 139200 | Power loss, max. 3) | | | | | | | | | kW | 1.9 | 2.1 | 3.2 | 4.6 | 5.5 | 6.9 | | kW | 1.9 | 2.1 | 3.2 | 4.6 | 5.5 | 6.9 | Cooling air requirement | m3/s | 0.17 | 0.17 | 0.17 | 0.36 | 0.36 | 0.36 | Sound pressure level LpA (1 m) at 50/60 Hz | dB | 66/68 | 66/68 | 66/68 | 71/73 | 71/73 | 71/73 | PE/GND connection | | PE bar | PE bar | PE bar | PE bar | PE bar | PE bar | | mm2 | 600 | 600 | 600 | 600 | 600 | 600 | - Conductor cross-section, max. (IEC)
| mm2 | 240 | 240 | 240 | 240 | 240 | 240 | Cable length, max. 4) | | | | | | | | | m | 2600 | 2600 | 2600 | 4000 | 4000 | 4800 | | m | 3900 | 3900 | 3900 | 6000 | 6000 | 7200 | Degree of protection | | IP20 | IP20 | IP20 | IP20 | IP20 | IP20 | Dimensions | | | | | | | | | mm | 400 | 400 | 400 | 400/600/600 | 400/600/600 | 400/600/600 | | mm | 2200 | 2200 | 2200 | 2200 | 2200 | 2200 | | mm | 600 | 600 | 600 | 600 | 600 | 600 | Weight, approx. | kg | 166 | 166 | 166 | 320/440/480 | 320/440/480 | 320/440/480 | Frame size | | FB | FB | FB | GB | GB | GD | Short-circuit current rating according to IEC | kA | 65 | 65 | 65 | 84 | 100 | 100 | Minimum short-circuit current 6) | A | 4400 | 5200 | 10000 | 2500 | 3200 | 4000 | - For connection in parallel
| A | – | – | – | 4000 | 5000 | 6400 |
1) The base-load current IH DC is the basis for a duty cycle of 150 % for 60 s or Imax DC for 5 s with a duty cycle duration of 300 s. 2) The current demand for the 400 V AC auxiliary power supply is drawn from the line input voltage. 3) The specified power loss represents the maximum value at 100% utilization. The value is lower under normal operating conditions. 4) Total of all motor cables and DC link. Longer cable lengths for specific configurations are available on request. 5) The cabinet height increases by 250 mm with degree of protection IP21, and by 400 mm with degrees of protection IP23, IP43 or IP54. 6) Current required to ensure reliable tripping of installed protective devices. Line voltage 500 ... 690 V 3 AC | Basic Line Modules |
|---|
| 6SL3730-1TG33-0AA3 | 6SL3730-1TG34-3AA3 | 6SL3730-1TG36-8AA3 | 6SL3730-1TG41-1AA3 | 6SL3730-1TG41-4AA3 | 6SL3730-1TG41-8AA3 |
|---|
For a parallel circuit configuration, mounted to the right of the Line Connection Module | | | | 6SL3730-1TG41-1BA3 | 6SL3730-1TG41-4BA3 | 6SL3730-1TG41-8BA3 |
|---|
For a parallel circuit configuration, mounted to the left of the Line Connection Module | | | | 6SL3730-1TG41-1BC3 | 6SL3730-1TG41-4BC3 | 6SL3730-1TG41-8BC3 |
|---|
Rated power | | | | | | | | - At Irated DC (50 Hz 690 V)
| kW | 250 | 355 | 560 | 900 | 1100 | 1500 | | kW | 195 | 280 | 440 | 710 | 910 | 1220 | - At Irated DC (50 Hz 500 V)
| kW | 175 | 250 | 390 | 635 | 810 | 1085 | | kW | 165 | 235 | 365 | 595 | 755 | 1015 | - At Irated DC (60 Hz 575 V)
| hp | 250 | 350 | 600 | 900 | 1250 | 1500 | | hp | 200 | 300 | 450 | 800 | 1000 | 1250 | DC link current | | | | | | | | | A | 300 | 430 | 680 | 1100 | 1400 | 1880 | - Base-load current IH DC1)
| A | 234 | 335 | 530 | 858 | 1092 | 1467 | | A | 450 | 645 | 1020 | 1650 | 2100 | 2820 | Input current | | | | | | | | | A | 260 | 375 | 575 | 925 | 1180 | 1580 | | A | 390 | 563 | 863 | 1388 | 1770 | 2370 | Current demand | | | | | | | | - 24 V DC auxiliary power supply
| A | 1.1 | 1.1 | 1.1 | 1.1 | 1.1 | 1.1 | | A | Internal | Internal | Internal | Internal | Internal | Internal | DC link capacitance | | | | | | | | | μF | 3200 | 4800 | 7300 | 11600 | 15470 | 19500 | | μF | 25600 | 38400 | 58400 | 92800 | 123760 | 78000 | Power loss, max. 3) | | | | | | | | | kW | 1.5 | 2.1 | 3 | 5.4 | 5.8 | 7.3 | | kW | 1.5 | 2.1 | 3 | 5.4 | 5.8 | 7.3 | Cooling air requirement | m3/s | 0.17 | 0.17 | 0.17 | 0.36 | 0.36 | 0.36 | Sound pressure level LpA (1 m) at 50/60 Hz | dB | 66/68 | 66/68 | 66/68 | 71/73 | 71/73 | 71/73 | PE/GND connection | | PE bar | PE bar | PE bar | PE bar | PE bar | PE bar | | mm2 | 600 | 600 | 600 | 600 | 600 | 600 | - Conductor cross-section, max. (IEC)
| mm2 | 240 | 240 | 240 | 240 | 240 | 240 | Cable length, max. 4) | | | | | | | | | m | 1500 | 1500 | 1500 | 2250 | 2250 | 2750 | | m | 2250 | 2250 | 2250 | 3375 | 3375 | 4125 | Degree of protection | | IP20 | IP20 | IP20 | IP20 | IP20 | IP20 | Dimensions | | | | | | | | | mm | 400 | 400 | 400 | 400/600/600 | 400/600/600 | 400/600/600 | | mm | 2200 | 2200 | 2200 | 2200 | 2200 | 2200 | | mm | 600 | 600 | 600 | 600 | 600 | 600 | Weight, approx. | kg | 166 | 166 | 166 | 320/440/480 | 320/440/480 | 320/440/480 | Frame size | | FB | FB | FB | GB | GB | GD | Short-circuit current rating according to IEC | kA | 65 | 65 | 84 | 100 | 100 | 100 | Minimum short-circuit current 6) | A | 3000 | 4400 | 8000 | 2000 | 2500 | 3200 | - For connection in parallel
| A | – | – | – | 4000 | 5000 | 6400 |
1) The base-load current IH DC is the basis for a duty cycle of 150 % for 60 s or Imax DC for 5 s with a duty cycle duration of 300 s. 2) The current demand for the 500 V/690 V AC auxiliary power supply is drawn from the line input voltage. 3) The specified power loss represents the maximum value at 100% utilization. The value is lower under normal operating conditions. 4) Total of all motor cables and DC link. Longer cable lengths for specific configurations are available on request. 5) The cabinet height increases by 250 mm with degree of protection IP21, and by 400 mm with degrees of protection IP23, IP43 or IP54. 6) Current required to ensure reliable tripping of installed protective devices.
|