Motor type | Permanent-magnet synchronous motor |
Magnet material | Rare-earth magnet material |
Cooling | Natural cooling, forced ventilation, water cooling |
Temperature monitoring | Temperature sensor in stator winding |
Stator winding insulation in accordance with EN 60034-1 (IEC 60034-1) | Temperature class 155 (F) for a winding temperature rise of О”T = 100 K at an ambient temperature of 40 °C (104 °F) For water cooling, max. inlet temperature 30 °C (86 °F) Avoid condensation |
Type of construction in accordance with EN 60034-7 (IEC 60034-7) | IM B5 (IM V1, IM V3) with recessed flange (more compact) or with flange compatible with 1FT6/1FK7 |
Degree of protection in accordance with EN 60034-5 (IEC 60034-5) | IP64/IP65/IP67 |
Shaft extension at DE in accordance with DIN 748-3 (IEC 60072-1) | Plain shaft/ feather key and keyway (half-key balancing) |
Shaft and flange accuracy in accordance with DIN 42955 (IEC 60072-1)1) | Tolerance N/tolerance R |
Vibration severity in accordance with EN 60034-14 (IEC 60034-14) | Grade A is maintained up to rated speed/Grade R |
Sound pressure level LpA (1 m) in accordance with EN ISO 1680, max. Tolerance + 3 dB | |
Natural/water cooling - 1FT703
- 1FT704 ... 1FT706
- 1FT708 ... 1FT710
| 60 dB 65 dB 70 dB |
Forced ventilation | 73 dB |
Connection | Connectors for signals and power rotatable |
Paint finish | Pearl dark grey RAL 9023 |
2nd rating plate | Enclosed separately |
Holding brake | Without/with |
Certificate of suitability | cURus |