Tap-off Units for International UseMolded plastic-enclosed outgoing unitsCommon features - Molded-plastic enclosure
- Partially transparent cover for protective devices
- Power pick-up through silver-plated horseshoe contacts
- Reliable prevention of incorrect mounting
- Cable entry is from one side only (use plastic cable glands with strain relief, not included in scope of supply).
- The tap-off unit must first be removed from the trunking before it can be opened and the cable can be connected.
- The connecting cable should be supported separately if necessary.
Tap-off units with components fitted - Two sizes (16 A and 32 A) for 3 cylindrical fuses (10 mm ? 38 mm)
- One size with 3 MW space requirement (1 MW = 18 mm)
There are various versions with fuse bases, miniature circuit breakers, Schuko socket outlets and CEE socket outlets up to and including 32 A  BD01-AK01X/ZS  BD01-AK02X/ZS3  BD01-AK02M0/ CEE165A163 Tap-off units for free arrangement of components - One size with 3 MW space requirement (1 MW = 18 mm), for operation from the outside through a hinge switch integrated in the cover.
- Installation of devices (e.g. miniature circuit breakers) according to DIN 43871 up to and including 32 A possible
 BD01-AK02M0/F Tap-off units made of aluminiumCommon features - The enclosure is made from aluminum and molded plastic at both ends.
- A standard mounting rail is built-in for component mounting.
- Power pick-up through silver-plated horseshoe contacts
- The isolator built into the tap-off unit ensures that the tap-off unit is voltage-free when the cover is open.
- The tap-off unit can only be fitted to or removed from the tap-off point with its cover open (contacts retracted).
- Reliable prevention of incorrect mounting
- Cable entry is possible from three directions (use plastic cable glands with strain relief; not included in scope of supply).
- Can be combined with ancillary equipment units for additional functions.
- The connecting cables should be supported separately if necessary.
Tap-off units with components fitted - Two sizes with 4 MW or 8 MW space requirement (1 MW = 18 mm)
- Various versions with fuse bases, miniature circuit breakers up to and including 63 A, Schuko and CEE socket outlets up to and including 32 A
- Versions with fitted miniature circuit breaker have a device installation unit.
 BD01-AK1M1/A163  BD01-AK2M1/ CEE165A163 Tap-off units for free arrangement of components - Two sizes with 4 MW and 8 MW space requirement (1 MW = 18 mm)
- Without or with device installation unit for external actuation (2 sizes with 4 MW and 8 MW)
- Installation of devices (e.g. miniature circuit breakers) according to DIN 43871 up to and including 63 A possible
 BD01-AK1M1/F Country-specific tap-off unitsThese tap-off units contain equipment according to typical national requirements, such as special socket outlets.
|