Transfer rate | 50 to 38,400 bits/s |
Interfaces | |
- 1st connection for external data transmission device
| 1 x 9-pin Sub D connector, RS232 can be switched to RS485 |
- 2nd connection for external data transmission device
| 1x RJ45; conversion to 9-pin Sub D connector is possible over the interface adapter cable supplied, RS232 can be switched to RS485 |
| 1 x 9-pin Sub D socket |
| 1 x BNC socket (via supplied DCF77 adapter cable) |
- Connection for supply voltage
| 1 x 4-pin terminal block |
Cable length | |
| max. 6 m |
| max. 30 m |
Supply voltage | 24 VDC; min. 20.4 V, max. 28.8 V |
Current consumption | |
| 60 mA (only if the TIM is used as a CP in an S7-300 rack) |
| 500 mA |
Power loss | 12.3 W |
Permissible ambient conditions | |
| 0 °C to +60 °C |
- Transport/storage temperature
| -40 °C to +70 °C |
| Max. 95 % at +25 °C |
Design | |
| Compact module S7-300, double width |
- Dimensions (W x H x D) in mm
| 80 x 125 x 120 |
| Approx. 300 g |
Degree of protection | IP 20 |
Configuration | |
| SINAUT ST7 configuring software for PG |
| SINAUT TD7 function block library for CPU |
- Storage of TIM configuration data
| On internal TIM flash memory |
TIM interfaces can be operated with this function | |
| Yes |
| Yes |
| Yes |
Number of TIM 4Rs per S7 CPU | More than one; number depends on the connection resources of the S7 CPU |
Local communication in the rack of an S7-300 | |
- Via backplane bus with local S7-300 CPU
| Yes, over TD7onCPU 1) |
- Via backplane bus with further local TIMs
| Yes |
- Via MPI port of local S7-300 CPU 2) with further CPUs and/or PCs
| Yes, through TD7onCPU (for S7-300 and S7-400) and S7 communication (for ST7cc/ST7sc) |
Special communication in stand-alone mode | |
- Via MPI port of the TIM with CPUs and/or PCs
| Yes, through TD7onCPU (for S7-300 and S7-400) and S7 communication (for ST7cc/ST7sc) |
User memory required in S7 CPU | Minimum 20 KB, actual requirement determined by data volume and functional scope |
Message memory on TIM | about 10,000 message frames |
Transmission protocols | |
Available protocols | SINAUT ST7 SINAUT ST1 |
Operating mode for dedicated line/radio network | |
| Polling Polling with time-slot procedure Multi-master polling with time-slot procedure |
| Polling Polling with time-slot procedure |
Operating mode for dial-up network | |
| spontaneous |
| spontaneous |
Asynchronous character format | |
- SINAUT ST7 protocol, polling or spontaneous
| 10 or 11 bits |
- SINAUT ST7 protocol, multi-master polling
| 10 bits |
- SINAUT ST1 protocol, polling
| 11 bits |
- SINAUT ST1 protocol, spontaneous
| 10 or 11 bits |
Hamming distance d | |
| 4 |
| 4 |