CU310 DP Control UnitThe CU310 DP Control Unit has the following interfaces as standard: - 1 DRIVE-CLiQ socket to allow communication with other DRIVE-CLiQ nodes
- 1 PM-IF interface for communication with Power Modules in blocksize format
- 1 interface to the BOP20 Basic Operator Panel
- 1 PROFIBUS interface with PROFIdrive profile
- 1 encoder evaluation
The following encoder signals can be evaluated:
- Incremental encoder TTL/HTL
- SSI encoder without incremental signals
- 4 parameterizable digital inputs (isolated)
- 4 parameterizable bidirectional digital inputs/digital outputs (non-floating)
- 1 serial RS232 interface
- 1 slot for the CompactFlash card on which firmware and parameters are stored
- 3 test sockets and one reference ground for commissioning support
- 1 connection for the electronics power supply via the 24 V DC supply connector
- 1 PE/protective conductor connection
- 1 connection for Safety Integrated
- 1 temperature sensor input (KTY84-130 or PTC)
The status of the CU310 DP Control Unit is indicated via multicolor LEDs. A BOP20 Basic Operator Panel can be snapped directly onto the CU310 DP Control Unit, e.g. for diagnostic purposes. As the firmware and parameter settings are stored on a plug-in CompactFlash card, the Control Unit can be changed without the need for software tools.
|