510 ... 720 V DC (line supply voltage 380 ... 480 V 3 AC) or 675 ... 1035 V DC (line supply voltage 500 ... 690 V3 AC)
Efficiency
> 98.5 %
Output frequency 1)
Control type Servo
0 … 650 Hz
Control type Vector
0 … 600 Hz
Control type V/f
0 … 600 Hz
Conformity
CE (EMC Directive No. 2004/108/EC and Low-Voltage Directive No. 2006/95/EC)
Approvals, according to
cULus (only for drive units connected to line voltages 380 ... 480 V 3 AC and 500 ... 600 V 3 AC)
Safety Integrated
Safety Integrity Level 2 (SIL2) acc. to IEC 61508, Performance Level d (PLd) acc. to EN ISO 13849-1 and Control Category 3 acc. to EN ISO 13849-1 (previously EN 954-1).
1) Please note: - The correlation between the maximum output frequency, pulse frequency and current derating. Higher output frequencies for specific configurations are available on request. - The correlation between the minimum output frequency and permissible output current (current derating). Information is provided in the SINAMICS Low Voltage Engineering Manual.
Line voltage 380 … 480 V 3 AC DC link voltage 510 … 720 V DC
Motor Modules
6SL3325-1TE32-1AA3
6SL3325-1TE32-6AA3
6SL3325-1TE33-1AA3
6SL3325-1TE35-0AA3
Type rating
For IL (50 Hz 400 V) 1)
kW
110
132
160
250
For IH (50 Hz 400 V) 1)
kW
90
110
132
200
For IL (60 Hz 460 V) 2)
hp
150
200
250
400
For IH (60 Hz 460 V) 2)
hp
150
200
200
350
Output current
Rated current IN A
A
210
260
310
490
Base load current IL 3)
A
205
250
302
477
Base load current IH 4)
A
178
233
277
438
Maximum current Imax A
A
307
375
453
715
DC link current
Rated current IN DC when supplied from
Basic Line Module
A
256
317
380
600
Active Line Module
A
230
287
340
538
Base load current IL DC3) when supplied from
Basic Line Module
A
250
305
368
581
Active Line Module
A
225
274
331
522
Base load current IH DC 4) when supplied from
Basic Line Module
A
227
284
338
534
Active Line Module
A
195
255
303
480
Current demand
24 V DC auxiliary power supply
A
1.4
1.4
1.5
1.5
DC link capacitance
?F
4800
5800
8400
9600
Pulse frequency 5)
Rated frequency
kHz
2
2
2
2
Pulse frequency, max.
Without current derating
kHz
2
2
2
2
With current derating
kHz
8
8
8
8
Power loss, at 50 Hz 400 V 6)
Dissipated to the coolant
kW
1.55
1.88
2.2
3.42
Dissipated to the ambient air
kW
0.06
0.07
0.09
0.14
Total
kW
1.61
1.95
2.29
3.56
Coolant flow rate 7)
l/min
9
9
12
12
Volume of liquid
in the integrated heat exchanger
dm3
0.31
0.31
0.91
0.91
Pressure drop, typ. 8)
for volumetric flow
Pa
70000
70000
70000
70000
Heat exchanger material
Stainless steel
Stainless steel
Stainless steel
Stainless steel
Sound pressure level LpA
(1 m) at 50/60 Hz
dB
52
52
52
52
DC link connection
DCP, DCN
2 ? hole for M12
Busbar
2 ? hole for M12
Busbar
2 ? hole for M12
Busbar
2 ? hole for M12
Busbar
Motor connection
U2, V2, W2
Hole for M12
Hole for M12
Hole for M12
Hole for M12
Conductor cross-section, max. (IEC)
mm2
2 ? 95
2 ? 95
2 ? 240
2 ? 240
Cable length, max. 9)
Shielded
m
300
300
300
300
Unshielded
m
450
450
450
450
PE/GND connection
2 ? hole for M12
2 ? hole for M12
2 ? hole for M12
2 ? hole for M12
Conductor cross-section, max. (IEC)
mm2
2 ? 95
2 ? 95
2 ? 240
2 ? 240
Degree of protection
IP00
IP00
IP00
IP00
Dimensions
Width
mm
150
150
150
150
Height
mm
746
746
1172
1172
Depth
mm
545
545
545
545
Weight, approx.
kg
41
41
80
80
Frame size
FXL
FXL
GXL
GXL
1) Rated power of a typ. 6-pole standard induction motor based on IL or IH with 400 V 3 AC 50 Hz.
2) Rated power of a typ. 6-pole standard induction motor based on IL or IH with 460 V 3 AC 60 Hz.
3) The base load current IL is the basis for a duty cycle of 110 % for 60 s or 150 % for 10 s with a duty cycle duration of 300 s.
4) The base load current IH is the basis for a duty cycle of 150 % for 60 s or 160 % for 10 s with a duty cycle duration of 300 s.
5)Additional notes regarding the correlation between the pulse frequency and maximum output current/output frequency is provided in the SINAMICS Low Voltage Engineering Manual.
6) The specified power loss represents the maximum value at 100 % utilization. The value is lower under normal operating conditions.
7) The value applies to water and a mixture of water and Antifrogen N mixture with 45 % Antifrogen N as coolant.
8) The value is valid for water as coolant. Additional information and notes on other coolants is provided in the SINAMICS Low Voltage Engineering Manual.
9) Sum of all motor cables. Longer cable lengths for specific configurations are available on request. For additional information, please refer to the SINAMICS Low Voltage Engineering Manual.
Line voltage 380 … 480 V 3 AC DC link voltage 510 … 720 V DC
Motor Modules
6SL3325-1TE36-1AA3
6SL3325-1TE38-4AA3
6SL3325-1TE41-0AA3
6SL3325-1TE41-4AA3
Type rating
For IL (50 Hz 400 V) 1)
kW
315
450
560
800
For IH (50 Hz 400 V) 1)
kW
250
400
450
710
For IL (60 Hz 460 V) 2)
hp
500
700
800
1000
For IH (60 Hz 460 V) 2)
hp
350
600
700
1000
Output current
Rated current IN A
A
605
840
985
1405
Base load current IL 3)
A
590
820
960
1370
Base load current IH 4)
A
460
700
860
1257
Maximum current Imax A
A
885
1230
1440
2055
DC link current
Rated current IN DC when supplied from
Basic Line Module
A
738
1025
1202
1714
Active Line Module
A
664
922
1080
1544
Base load current IL DC3) when supplied from
Basic Line Module
A
719
1000
1170
1670
Active Line Module
A
646
898
1051
1500
Base load current IH DC 4) when supplied from
Basic Line Module
A
561
853
1048
1532
Active Line Module
A
504
767
942
1377
Current demand
24 V DC auxiliary power supply
A
1.6
1.6
1.46
1.46
DC link capacitance
?F
12600
17400
21000
29000
Pulse frequency 5)
Rated frequency
kHz
1.25
1.25
1.25
1.25
Pulse frequency, max.
Without current derating
kHz
1.25
1.25
1.25
1.25
With current derating
kHz
7.5
7.5
7.5
7.5
Power loss, at 50 Hz 400 V 6)
Dissipated to the coolant
kW
4.65
5.52
7.46
9.53
Dissipated to the ambient air
kW
0.16
0.23
0.48
0.62
Total
kW
4.81
5.75
7.94
10.15
Coolant flow rate 7)
l/min
16
16
27
27
Volume of liquid
in the integrated heat exchanger
dm3
0.74
0.74
1.56
1.56
Pressure drop, typ. 8)
for volumetric flow
Pa
70000
70000
70000
70000
Heat exchanger material
Aluminum
Aluminum
Aluminum
Aluminum
Sound pressure level LpA
(1 m) at 50/60 Hz
dB
54
54
56
56
DC link connection
DCP, DCN
2 ? hole for M12
Busbar
2 ? hole for M12
Busbar
2 ? hole for M12
Busbar
2 ? hole for M12
Busbar
Motor connection
U2, V2, W2
2 ? hole for M12
2 ? hole for M12
2 ? hole for M12
2 ? hole for M12
Conductor cross-section, max. (IEC)
mm2
4 ? 185
4 ? 185
4 ? 240
4 ? 240
Cable length, max. 9)
Shielded
m
300
300
300
300
Unshielded
m
450
450
450
450
PE/GND connection
2 ? hole for M12
2 ? hole for M12
2 ? hole for M12
2 ? hole for M12
Conductor cross-section, max. (IEC)
mm2
4 ? 185
4 ? 185
Busbar
Busbar
Degree of protection
IP00
IP00
IP00
IP00
Dimensions
Width
mm
265
265
295
295
Height
mm
1002
1002
1516
1516
Depth
mm
545
545
545
545
Weight, approx.
kg
110
110
220
220
Frame size
HXL
HXL
JXL
JXL
1) Rated power of a typ. 6-pole standard induction motor based on IL or IH with 400 V 3 AC 50 Hz.
2) Rated power of a typ. 6-pole standard induction motor based on IL or IH with 460 V 3 AC 60 Hz.
3) The base load current IL is the basis for a duty cycle of 110 % for 60 s or 150 % for 10 s with a duty cycle duration of 300 s.
4) The base load current IH is the basis for a duty cycle of 150 % for 60 s or 160 % for 10 s with a duty cycle duration of 300 s.
5)Additional notes regarding the correlation between the pulse frequency and maximum output current/output frequency is provided in the SINAMICS Low Voltage Engineering Manual.
6) The specified power loss represents the maximum value at 100 % utilization. The value is lower under normal operating conditions.
7) The value applies to water and a mixture of water and Antifrogen N mixture with 45 % Antifrogen N as coolant.
8) The value is valid for water as coolant. Additional information and notes on other coolants is provided in the SINAMICS Low Voltage Engineering Manual.
9) Sum of all motor cables. Longer cable lengths for specific configurations are available on request. For additional information, please refer to the SINAMICS Low Voltage Engineering Manual.
Line voltage 500 … 690 V 3 AC DC link voltage 675 … 1035 V DC
Motor Modules
6SL3325-1TG31-0AA3
6SL3325-1TG31-5AA3
6SL3325-1TG32-2AA3
6SL3325-1TG33-3AA3
Rated power
For IL (50 Hz 690 V) 1)
kW
90
132
200
315
For IH (50 Hz 690 V) 1)
kW
75
110
160
250
For IL (50 Hz 500 V) 1)
kW
55
90
132
200
For IH (50 Hz 500 V) 1)
kW
55
90
132
200
For IL (60 Hz 575 V) 2)
hp
75
150
200
300
For IH (60 Hz 575 V) 2)
hp
75
125
200
250
Output current
Rated current IN A
A
100
150
215
330
Base load current IL 3)
A
95
142
208
320
Base load current IH 4)
A
89
134
192
280
Maximum current Imax A
A
142
213
312
480
DC link current
Rated current IN DC when supplied from
Basic Line Module
A
122
183
263
403
Active Line Module
A
110
165
237
363
Base load current IL DC3) when supplied from
Basic Line Module
A
116
173
253
390
Active Line Module
A
105
156
229
352
Base load current IH DC 4) when supplied from
Basic Line Module
A
108
163
234
341
Active Line Module
A
98
147
211
308
Current demand
24 V DC auxiliary power supply
A
1.0
1.0
1.5
1.5
DC link capacitance
?F
2800
2800
4200
5800
Pulse frequency 5)
Rated frequency
kHz
1.25
1.25
1.25
1.25
Pulse frequency, max.
Without current derating
kHz
1.25
1.25
1.25
1.25
With current derating
kHz
7.5
7.5
7.5
7.5
Power loss, at 50 Hz 500/690 V 6)
Dissipated to the coolant
kW
0.8/1.09
1.15/1.57
1.65/2.25
2.4/3.27
Dissipated to the ambient air
kW
0.06
0.07
0.09
0.11
Total
kW
0.86/1.15
1.22/1.64
1.74/2.34
2.51/3.38
Coolant flow rate 7)
l/min
9
9
12
12
Volume of liquid
in the integrated heat exchanger
dm3
0.31
0.31
0.91
0.91
Pressure drop, typ. 8)
for volumetric flow
Pa
70000
70000
70000
70000
Heat exchanger material
Stainless steel
Stainless steel
Stainless steel
Stainless steel
Sound pressure level LpA
(1 m) at 50/60 Hz
dB
52
52
52
52
DC link connection
DCP, DCN
2 ? hole for M12
Busbar
2 ? hole for M12
Busbar
2 ? hole for M12
Busbar
2 ? hole for M12
Busbar
Motor connection
U2, V2, W2
Hole for M12
Hole for M12
Hole for M12
Hole for M12
Conductor cross-section, max. (IEC)
mm2
2 ? 95
2 ? 95
4 ? 240
4 ? 240
Cable length, max. 9)
Shielded
m
300
300
300
300
Unshielded
m
450
450
450
450
PE/GND connection
2 ? hole for M12
2 ? hole for M12
2 ? hole for M12
2 ? hole for M12
Conductor cross-section, max. (IEC)
mm2
2 ? 95
2 ? 95
2 ? 240
2 ? 240
Degree of protection
IP00
IP00
IP00
IP00
Dimensions
Width
mm
150
150
150
150
Height
mm
728
728
1172
1172
Depth
mm
545
545
545
545
Weight, approx.
kg
41
41
80
80
Frame size
FXL
FXL
GXL
GXL
1) Rated power of a typ. 6-pole standard induction motor based on IL or IH with 500 V or 690 V 3 AC 50 Hz.
2) Rated power of a typ. 6-pole standard induction motor based on IL or IH with 575 V 3 AC 60 Hz.
3) The base load current IL is the basis for a duty cycle of 110 % for 60 s or 150 % for 10 s with a duty cycle duration of 300 s.
4) The base load current IH is the basis for a duty cycle of 150 % for 60 s or 160 % for 10 s with a duty cycle duration of 300 s.
5)Additional notes regarding the correlation between the pulse frequency and maximum output current/output frequency is provided in the SINAMICS Low Voltage Engineering Manual.
6) The specified power loss represents the maximum value at 100 % utilization. The value is lower under normal operating conditions.
7) The value applies to water and a mixture of water and Antifrogen N mixture with 45 % Antifrogen N as coolant.
8) The value is valid for water as coolant. Additional information and notes on other coolants is provided in the SINAMICS Low Voltage Engineering Manual.
9) Sum of all motor cables. Longer cable lengths for specific configurations are available on request. For additional information, please refer to the SINAMICS Low Voltage Engineering Manual.
Line voltage 500 … 690 V 3 AC DC link voltage 675 … 1035 V DC
Motor Modules
6SL3325-1TG35-8AA3
6SL3325-1TG38-1AA3
6SL3325-1TG41-0AA3
6SL3325-1TG41-3AA3
Rated power
For IL (50 Hz 690 V) 1)
kW
560
800
1000
1200
For IH (50 Hz 690 V) 1)
kW
450
710
900
1000
For IL (50 Hz 500 V) 1)
kW
400
560
710
900
For IH (50 Hz 500 V) 1)
kW
315
560
630
800
For IL (60 Hz 575 V) 2)
hp
600
800
1000
1250
For IH (60 Hz 575 V) 2)
hp
500
700
900
1000
Output current
Rated current IN A
A
575
810
1025
1270
Base load current IL 3)
A
560
790
1000
1230
Base load current IH 4)
A
514
724
917
1136
Maximum current Imax A
A
840
1185
1500
1845
DC link current
Rated current IN DC when supplied from
Basic Line Module
A
702
990
1250
1550
Active Line Module
A
632
891
1125
1395
Base load current IL DC3) when supplied from
Basic Line Module
A
683
963
1219
1500
Active Line Module
A
616
869
1100
1353
Base load current IH DC 4) when supplied from
Basic Line Module
A
627
883
1118
1384
Active Line Module
A
565
796
1009
1250
Current demand
24 V DC auxiliary power supply
A
1.6
1.46
1.46
1.46
DC link capacitance
?F
9670
14000
16000
19330
Pulse frequency 5)
Rated frequency
kHz
1.25
1.25
1.25
1.25
Pulse frequency, max.
Without current derating
kHz
1.25
1.25
1.25
1.25
With current derating
kHz
7.5
7.5
7.5
7.5
Power loss, at 50 Hz 500/690 V 6)
Dissipated to the coolant
kW
4.0/5.45
6.55/9.11
7.5/10.37
9.36/12.92
Dissipated to the ambient air
kW
0.16
0.45
0.5
0.57
Total
kW
4.16/5.61
7.0/9.56
8.0/10.87
9.93/13.49
Coolant flow rate 7)
l/min
16
27
27
27
Volume of liquid
in the integrated heat exchanger
dm3
0.74
1.56
1.56
1.56
Pressure drop, typ. 8)
for volumetric flow
Pa
70000
70000
70000
70000
Heat exchanger material
Aluminum
Aluminum
Aluminum
Aluminum
Sound pressure level LpA
(1 m) at 50/60 Hz
dB
54
56
56
56
DC link connection
DCP, DCN
2 ? hole for M12
Busbar
2 ? hole for M12
Busbar
2 ? hole for M12
Busbar
2 ? hole for M12
Busbar
Motor connection
U2, V2, W2
2 ? hole for M12
2 ? hole for M12
2 ? hole for M12
2 ? hole for M12
Conductor cross-section, max. (IEC)
mm2
4 ? 185
4 ? 240
4 ? 240
4 ? 240
Cable length, max. 9)
Shielded
m
300
300
300
300
Unshielded
m
450
450
450
450
PE/GND-Anschluss
2 ? hole for M12
2 ? hole for M12
2 ? hole for M12
2 ? hole for M12
Conductor cross-section, max. (IEC)
mm2
4 ? 185
Busbar
Busbar
Busbar
Degree of protection
IP00
IP00
IP00
IP00
Dimensions
Width
mm
265
295
295
295
Height
mm
1002
1516
1516
1516
Depth
mm
545
545
545
545
Weight, approx.
kg
110
220
220
220
Frame size
HXL
JXL
JXL
JXL
1) Rated power of a typ. 6-pole standard induction motor based on IL or IH at 500 V or 690 V 3 AC 50 Hz.
2) Rated power of a typ. 6-pole standard induction motor based on IL or IH at 575 V 3 AC 60 Hz.
3) The base load current IL is the basis for a duty cycle of 110 % for 60 s or 150 % for 10 s with a duty cycle duration of 300 s.
4) The base load current IH is the basis for a duty cycle of 150 % for 60 s or 160 % for 10 s with a duty cycle duration of 300 s.
5)Additional notes regarding the correlation between the pulse frequency and maximum output current/output frequency is provided in the SINAMICS Low Voltage Engineering Manual.
6) The specified power loss represents the maximum value at 100 % utilization. The value is lower under normal operating conditions.
7) The value applies to water and a mixture of water and Antifrogen N mixture with 45 % Antifrogen N as coolant.
8) The value is valid for water as coolant. Additional information and notes on other coolants is provided in the SINAMICS Low Voltage Engineering Manual.
9) Sum of all motor cables. Longer cable lengths for specific configurations are available on request. For additional information, please refer to the SINAMICS Low Voltage Engineering Manual.
skener.ru
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Àðìàòóðà DENDOR
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Äàò÷èêè è èçìåðèòåëè
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Ðåãóëÿòîðû è ðåãèñòðàòîðû
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Ïíåâìàòè÷åñêîå îáîðóäîâàíèå
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Êðàíû è Êëàïàíû
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Èçìåðèòåëüíûå ïðèáîðû
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Ñèñòåìû áåñïðîâîäíîãî óïðàâëåíèÿ «óìíûé äîì»
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Áåñêîíòàêòíûå âûêëþ÷àòåëè Êîíå÷íûå âûêëþ÷àòåëè Îïòè÷åñêèå äàò÷èêè Ýíêîäåðû
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
SKW-FS - Óñòàíîâêà óìÿã÷åíèÿ
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
SKW-FK - Óñòàíîâêà îáåçæåëåçèâàíèÿ