Climatic conditions | |
Ambient temperature | +5° ... +40 °C (standard) |
- With heater in sheet-steel cabinet
| Min. -5 °C |
- With heating in GRP cabinet
| Min. -15 °C |
| Max. +52 °C |
Relative humidity | 75 % (annual average), non-condensing |
Sample gas conditions | |
Max. sample gas pressure at inlet to sample preparation system | 500 hPa (mbar) |
Max. moisture content in sample gas | 17 vol % (cooler type: CSS) 25 vol % (cooler type: EGK 2-19) |
Sample gas temperature | Max. 200 °C at cabinet entry |
Sample gas flow | Approx. 60 l/h per analyzer module |
Sampling probe (standard) | Dust load: < 2 g/m3 |
Mounting flange: DN 65, PN 6, form B |
Including temperature controller with PT100 |
With internal sampling tube, stainless steel, length: 1 m (can be shortened) |
With filter in probe, to 600 °C |
Sampling probe for higher temperatures and in other materials (optional) | On request |
Sample gas line, electrically heated | Max. 35 m, longer lengths on request |
Sample gas must not be flammable or explosive. |
Power supply | |
Supply 1 | 115 V AC, 50 … 60 Hz (-15 %, +10 %) |
Supply 2 | 230 V AC, 50 … 60 Hz (-15 %, +10 %) |
Supply 3 | 400 V AC, 50 … 60 Hz (-15 %, +10 %) |
Power | 4 000 VA max. |
System design | |
Fusing of electronic consumers | 1-pole or 2-pole (selectable) |
Sample gas cooler | 2-stage |
Output signals | 4 … 20 mA (corresponding to the analyzer information) |
Additional digital inputs and outputs via PLC (LOGO) |
Color | RAL 7035 |
Weight | Approx. 160 kg |
Sheet-steel cabinet/frame | Indoor installation |
GRP cabinet | Outdoor installation |
Explosion protection classification | Installation outside the Ex zone |
Degree of protection | IP 54 (avoid direct sunlight for outdoor installation) |
Calibration | Semi-automatic; AUTOCAL freely adjustable on U23 up to max. 24-hour interval |
Detailed information on the analyzers You can find detailed information on the analyzers: - in the "Continuous Gas Analyzers, extractive" chapter
- ULTRAMAT 23
- SIPROCESS UV600
|
Dimensions | |
Sheet-steel cabinet (with base) for indoor installation | 2 000 x 800 x 800 mm (H x W x D) |
GRP cabinet (with base) for indoor installation | 2 060 x 900 x 800 mm (H x W x D) |
500 mm spacing on the right or left must be provided for the cable inlet and connection of the heated sample gas line. |