SINAMICS G120P Cabinet, 110 kW to 400 kW

The most important directives and standards are listed below. These are used as basis for the SINAMICS G120P Cabinet drive inverter cabinet units and they must be carefully observed to achieve an EMC-compliant configuration that is safe both functionally and in operation.

European directives

2006/95/EC

Low-voltage directive:

Directive of the European Parliament and Council of December 12, 2006, on the approximation of the laws of the member states relating to electrical equipment designed for use within certain voltage limits

2004/108/EC

EMC directive:

Directive of the European Parliament and Council of December 15, 2004, which repeals directive 89/336/EEC, on the approximation of laws of the member states relating to electromagnetic compatibility

2006/42/EC

Machinery directive:

The directive of the European Parliament and Council of May 17, 2006 on machinery and for changing Directive 95/16/EC (amendment)

European standards

EN 60146?1?1

Semiconductor converters – General requirements and line-commutated converters

Part 1?1: Specification of basic requirements

EN 60204?1

Electrical equipment of machines

Part 1: General requirements

EN 60529

Degrees of protection provided by enclosures (IP code)

EN 61800?2

Adjustable speed electrical power drive systems

Part 2: General requirements – Rating specifications for low-voltage adjustable frequency a.c. power drive systems

EN 61800?3

Adjustable speed electrical power drive systems

Part 3: EMC product standard including specific test methods

EN 61800-5-1

Adjustable speed electrical power drive systems

Part 5: Safety requirements

Main section 1: Electrical and thermal requirements



 

General technical specifications

Electrical specifications

Line voltages

380 ... 480 V 3 AC ±10 % (-15% < 1 min)1)

Output ranges

110 ... 400 kW

Line system configurations

Grounded TN/TT systems and non-grounded IT systems

Line frequency

47 ... 63 Hz

Output frequency

0 ... 100 Hz

Offset factor cos ?

0.96

Power factor ?

0.75 ... 0.93

Efficiency

>98%

Overvoltage category

III to EN 61800?5?1

Closed-loop control modes

Vector control without sensor or U/f control

Fixed speeds

15 fixed speeds plus 1 minimum speed, parameterizable
(in the default setting, 3 fixed setpoints plus 1 minimum speed are selectable using terminal block/fieldbus system)

Skipped speed ranges

4, parameterizable

Setpoint resolution of the Control Unit

0.01 Hz

12 bit analog

Braking operation

DC braking, dynamic braking with optional Braking Module

Mechanical specifications

Degree of protection

IP20 (higher degrees of protection up to IP54 optional)

Protection class

I acc. to EN 61800?5?1

Touch protection

According to EN 50274 and BGV A3 when used as intended

Cabinet system

Schafer IS?1, doors with double-barb lock, base plates with cable entry possibilities, crane transport aid

Paint finish

RAL 7035 (indoor requirements)

Type of cooling

Forced air cooling AF to EN 60146

Ambient conditions

Storage

Transport

Operation

Ambient temperature

-25 ... +55 °C

-25 ... +70 °C
above -40 °C for 24 hours

0 ... 40 °C (32 ... 104 °F)
up to 50 °C (122 °F) see derating data

Relative humidity

(condensation not permissible)

5 ... 95 %

Class 1K4 to EN 60721?3?1

5 ... 95 %

Class 2K3 to EN 60721?3?2

5 ... 95 %

Class 3K3 to EN 60721?3?3

Environmental class/harmful chemical substances

Class 1C2 acc. to EN 60721?3?1

Class 2C2 acc. to EN 60721?3?2

Class 3C2 acc. to EN 60721?3?3

Organic/biological influences

Class 1B1 acc. to EN 60721?3?1

Class 2B1 acc. to EN 60721?3?2

Class 3B1 according to EN 60721?3?3
Restriction: No conductive dust particles permitted

Degree of pollution

2 acc. to EN 61800?5?1

Installation altitude

Up to 1000 m (3281 ft) above sea level without derating
> 1000 m (3281 ft) see derating data

Mechanical strength

Storage

Transport 2)

Operation

Vibratory load

Class 1M2 acc. to EN 60721?3?1

Class 2M2 acc. to EN 60721?3?2

Class 3M2 acc. to EN 60721?3?3

  • Deflection

1.5 mm at 5 ... 9 Hz

3.5 mm at 2 ... 9 Hz

0.075 mm at 10 ... 58 Hz

  • Acceleration

5 m/s2 at > 9 ... 200 Hz

10 m/s2 at > 9 ... 200 Hz

10 m/s2 at > 58 ... 200 Hz

Shock load

Class 1M2 acc. to EN 60721?3?1

Class 2M2 acc. to EN 60721?3?2

Class 3M2 acc. to EN 60721?3?3

  • Acceleration

40 m/s2 at 22 ms

150 m/s2 at 11 ms

50 m/s2 (5 ? g)/30 ms
150 m/s2 (15 ? g)/11 ms

Standards

Compliance with standards

CE, C-Tick, GOST-R (EAC), KC

CE marking

According to EMC Directive No. 2004/108/EC, Low Voltage Directive No. 2006/95/EC, Machinery Directive No. 2006/42/EC

Radio interference suppression

The SINAMICS G120P Cabinet inverter systems are not designed for connection to the public power network ("first environment"). Radio interference suppression is compliant with the EMC product standard for variable-speed drives EN 61800-3 "Second environment" (industrial line supplies). The equipment can cause electromagnetic interference when it is connected to the public network. However, if supplementary measures are taken (e.g. line filter, see option L00) operation in the "first environment" is possible.



Deviations from the specified classes are underlined.

1) For the option L01, the line voltage is limited to 380 to 400 V AC ±10%.

2) In transport packaging.

 

Line voltage 380 ... 480 V 3 AC

SINAMICS G120P Cabinet drive inverter cabinet units

 

6SL3710-1PE32?1.A0-Z

6SL3710-1PE32?5.A0-Z

6SL3710-1PE33?0.A0-Z

6SL3710-1PE33?7.A0-Z

6SL3710-1PE34?6.A0-Z

Rated power

 

 

 

 

 

 
  • At IL 400 V/50 Hz 1)

kW

110

132

160

200

250

  • At IL 460 V/60 Hz 2)

hp

125

150

200

250

300

  • At IH 400 V/50 Hz 1)

kW

90

110

132

160

200

  • At IH 460 V/60 Hz 2)

hp

100

100

150

200

200

Output current

 

 

 

 

 

 

  • Rated current Irated (400 V ±10 %)

A

205

245

300

370

460

  • Rated current Irated (480 V ±10 %)

A

160

184

245

308

369

  • Base-load current IL (400 V ±10 %) 3)

A

200

240

290

360

450

  • Base-load current IL (480 V ±10 %) 3)

A

156

180

240

302

361

  • Base-load current IH (400 V ±10 %) 4)

A

164

196

240

296

368

  • Base-load current IH (480 V ±10 %) 4)

A

128

147

196

247

295

  • Output current, max.

A

270

324

392

486

608

Input current

 

 

 

 

 

 

  • Rated current (400 V ±10 %) 5)

A

218

262

317

375

469

  • Rated current (480 V ±10 %) 5)

A

171

197

262

314

376

  • Base-load current IL (400 V ±10 %) 3)

A

213

257

307

365

459

  • Base-load current IL (480 V ±10 %) 3)

A

167

193

257

308

368

  • Base-load current IH (400 V ±10 %) 4)

A

175

210

254

300

375

  • Base-load current IH (480 V ±10 %) 4)

A

137

157

210

251

301

  • Input current, max.

A

288

347

415

493

620

Current requirement, 24 V DC auxiliary power supply 6)

 

 

 

 

 

 

  • Version A

A

1

1

1

1

1

  • Version C

A

0.5

0.5

0.5

0.5

0.5

Rated short-circuit current acc. to IEC

in conjunction with the specified fuses

kA

65

65

65

65

65

Minimum short-circuit current 7)

 

 

 

 

 

 

  • For 3NE1 fuses

A

3000

3600

4400

5200

6300

  • For 3NA3 fuses

A

5800

7300

9500

14000

20000

Power loss, max.

at Irated (400 V/40 °C)

 

 

 

 

 

 

  • Version A

kW

3.377

3.939

4.543

5.681

6.376

  • Version C

kW

2.831

3.255

3.901

4.777

5.482

Coolant

 

of air

of air

of air

of air

of air

Coolant requirements

m3/s (ft3/s)

0.21 (7.4)

0.21 (7.4)

0.21 (7.4)

0.21 (7.4)

0.21 (7.4)

Sound pressure level LpA(1 m) at 50/60 Hz

 

 

 

 

 

 

  • Version A

dB

66/66

66/66

66/66

66/66

66/66

  • Version C

dB

63/63

63/63

63/63

63/63

63/63

Cable length, max.

between Power Module and motor

 

 

 

 

 

 

  • When compliant with Categories C2 and C3 according to EN 61800?3
    shielded

m (ft)

100 (328.10)

100 (328.10)

100 (328.10)

100 (328.10)

100 (328.10)

  • When non-compliant with the limit values for RI suppression and without output reactor or dv/dt filter
    unshielded

m (ft)

200 (656)

200 (656)

200 (656)

200 (656)

200 (656)

  • When non-compliant with the limit values for RI suppression with output reactor or dv/dt filter
    shielded/unshielded

m (ft)

300/450 (984.30/1476.45)

300/450 (984.30/1476.45)

300/450 (984.30/1476.45)

300/450 (984.30/1476.45)

300/450 (984.30/1476.45)

Dimensions

 

 

 

 

 

 

  • Width for
    version A/C

mm (in)

1000/600 (39.37/23.62)

1000/600 (39.37/23.62)

1000/600 (39.37/23.62)

1000/600 (39.37/23.62)

1000/600 (39.37/23.62)

  • Height8)

mm (in)

2000 (78.74)

2000 (78.74)

2000 (78.74)

2000 (78.74)

2000 (78.74)

  • Depth

mm (in)

600 (23.62)

600 (23.62)

600 (23.62)

600 (23.62)

600 (23.62)

Frame size

 

GX

GX

GX

GX

GX

Weight

Versions A/C
(degree of protection IP20, without options)

kg (lb)

360/290 (794/639)

360/290 (794/639)

370/290 (816/639)

380/300 (838/661)

400/300 (882/661)



1) Rated power of a typ. 4-pole standard induction motor based on base-load current IL or IH at 400 V 3 AC/50 Hz.

2) Rated power of a typ. 4-pole standard induction motor based on base-load current IL or IH at 460 V 3 AC/60 Hz.

3) The base-load current IL is based on a duty cycle of 110% for 60 s or 135 % for 3 s with a duty cycle duration of 300 s (see overload capability characteristics).

4) The base-load current IH is based on a duty cycle of 150% for 60 s with a duty cycle duration of 300 s (see overload capability characteristics).

5) The current values given here are based on the rated output current.

6)If the drive closed-loop control is still to remain active when the main line supply fails, then the equipment must be provided with an external 24 V DC supply.

7) 10 ms value from current-time characteristic for reliable tripping of installed protection devices.

8)Version A: The cabinet height increases by 300 mm with IP20 and IP21 degrees of protection, and by 400 mm with IP23, IP43 and IP54 degrees of protection.Version C: The cabinet height increases by 300 mm for IP21 degree of protection, and by 400 mm for IP23, IP43 and IP54 degrees of protection.

Note:

If the minimum short-circuit current is not reached, the activation time of the fuses is increased, which can lead to damage.

Note:

The power data in hp units are based on the NEC/CEC standards for the North American market.

Information on the line connection, motor connection and cabinet grounding can be found in section Cable cross-sections and connections.

Line voltage 380 ... 480 V 3 AC

SINAMICS G120P Cabinet drive inverter cabinet units

 

6SL3710-1PE35?8.A0-Z

6SL3710-1PE36?6.A0-Z

6SL3710-1PE37?4.A0-Z

Rated power

 

   
  • At IL 400 V/50 Hz 1)

kW

315

355

400

  • At IL 460 V/60 Hz 2)

hp

400

450

500

  • At IH 400 V/50 Hz 1)

kW

250

250

315

  • At IH 460 V/60 Hz 2)

hp

300

300

350

Output current

 

   
  • Rated current Irated (400 V ±10 %)

A

585

655

735

  • Rated current Irated (480 V ±10 %)

A

487

526

602

  • Base-load current IL (400 V ±10 %) 3)

A

570

640

720

  • Base-load current IL (480 V ±10 %) 3)

A

477

515

590

  • Base-load current IH (400 V ±10 %) 4)

A

468

491

551

  • Base-load current IH (480 V ±10 %) 4)

A

390

394

452

  • Output current, max.

A

770

864

972

Input current

 

   
  • Rated current (400 V ±10 %) 5)

A

597

668

750

  • Rated current (480 V ±10 %) 5)

A

497

536

614

  • Base-load current IL (400 V ±10 %) 3)

A

585

654

735

  • Base-load current IL (480 V ±10 %) 3)

A

486

525

602

  • Base-load current IH (400 V ±10 %) 4)

A

477

501

562

  • Base-load current IH (480 V ±10 %) 4)

A

397

402

461

  • Input current, max.

A

785

881

992

Current requirement, 24 V DC auxiliary power supply 6)

 

   
  • Version A

A

1

1

1

  • Version C

A

0.5

0.5

0.5

Rated short-circuit current acc. to IEC

in conjunction with the specified fuses

kA

65

65

65

Minimum short-circuit current 7)

 

   
  • For 3NE1 fuses

A

9000

10000

12000

  • For 3NA3 fuses

A

20000

30000

30000

Power loss, max.

at Irated (400 V/40 °C)

 

   
  • Version A

kW

8.478

9.443

9.907

  • Version C

kW

7.143

8.026

8.824

Coolant

 

of air

of air

of air

Coolant requirements

m3/s (ft3/s)

0.6 (21.2)

0.6 (21.2)

0.6 (21.2)

Sound pressure level LpA(1 m) at 50/60 Hz

 

   
  • Version A

dB

69/69

69/69

69/69

  • Version C

dB

66/66

66/66

66/66

Cable length, max.

between Power Module and motor

 

   
  • When compliant with Categories C2 and C3 according to EN 61800?3
    shielded

m (ft)

100 (328.10)

100 (328.10)

100 (328.10)

  • When non-compliant with the limit values for RI suppression and without output reactor or dv/dt filter
    unshielded

m (ft)

200 (656.20)

200 (656.20)

200 (656.20)

  • When non-compliant with the limit values for RI suppression with output reactor or dv/dt filter
    shielded/unshielded

m (ft)

300/450 (984.30/1476.45)

300/450 (984.30/1476.45)

300/450 (984.30/1476.45)

Dimensions

 

   
  • Width for
    version A/C

mm (in)

1200 9)/800

1200 9)/800

1200 9)/800

  • Height8)

mm (in)

2000 (78.74)

2000 (78.74)

2000 (78.74)

  • Depth

mm (in)

600 (23.62)

600 (23.62)

600 (23.62)

Frame size

 

HX

HX

HX

Weight

Versions A/C
(degree of protection IP20, without options)

kg (lb)

500/430 (1102/948)

500/440 (1102/970)

530/440 (1169/970)



1) Rated power of a typ. 4-pole standard induction motor based on base-load current IL or IH at 400 V 3 AC/50 Hz.

2) Rated power of a typ. 4-pole standard induction motor based on base-load current IL or IH at 460 V 3 AC/60 Hz.

3) The base-load current IL is based on a duty cycle of 110% for 60 s or 135 % for 3 s with a duty cycle duration of 300 s (see overload capability characteristics).

4) The base-load current IH is based on a duty cycle of 150% for 60 s with a duty cycle duration of 300 s (see overload capability characteristics).

5) The current values given here are based on the rated output current.

6)If the drive closed-loop control is still to remain active when the main line supply fails, then the equipment must be provided with an external 24 V DC supply.

7) 10 ms value from current-time characteristic for reliable tripping of installed protection devices.

8) The cabinet height increases by 300 mm (11.81 in) for IP21 degree of protection, and by 400 mm (15.75 in) for IP23, IP43 and IP54 degrees of protection.

9) The specified cabinet widths increase depending on the options selected. For details, see description of options L01 and L10.

Note:

If the minimum short-circuit current is not reached, the activation time of the fuses is increased, which can lead to damage.

Note:

The power data in hp units are based on the NEC/CEC standards for the North American market.

Information on the line connection, motor connection and cabinet grounding can be found in section Cable cross-sections and connections.

















skener.ru

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Арматура DENDOR

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Датчики и измерители

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Регуляторы и регистраторы

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Пневматическое оборудование

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Краны и Клапаны

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Измерительные приборы

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Системы беспроводного управления «умный дом»

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Бесконтактные выключатели Конечные выключатели Оптические датчики Энкодеры

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
SKW-FS - Установка умягчения

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
SKW-FK - Установка обезжелезивания
Каталог оборудования 2016
Каталог продуктов Siemens Industry Приводная техника Преобразователи Стандартные преобразователи Общая информация о базовых преобразователях SINAMICS V Преобразователи частоты общего назначения SINAMICS G Преобразователи частоты SINAMICS G110 Компактные преобразователи SINAMICS G120C Преобразователи для насосов, вентиляторов,компрессоров SINAMICS G120P Highlights Введение Преобразователи для насосов, вентиляторов, компрессоров SINAMICS G120P Integrated Drive Systems SINAMICS G120P, built-in and wall-mounted units, IP20/IP54/IP55 SINAMICS G120P Cabinet, cab. units, degr. of prot. from IP20 to IP54 SINAMICS G120P Cabinet, 110 kW to 400 kW Line-side components Engineering tools Services and documentation Инструменты проектирования Сервис и документация Стандартные преобразователи SINAMICS G120 SINAMICS G110M distributed inverters Преобразователь частоты SINAMICS G110D для распределенной периферии Преобразователи частоты SINAMICS G120D Преобразователи SINAMICS G130 формат шасси Преобразователь частоты SINAMICS G150 шкафного исполнения SINAMICS G180 Высокопроизводительные преобразователи SINAMICS S MICROMASTER SIPLUS POSMO A SIMODRIVE POSMO LOHER DYNAVERT Drive System Преобразователи на среднее напряжение Преобразователи постоянного тока Двигатели переменного тока Мотор-редукторы Flender Gear Units Couplings Инструментальное программное обеспечение Дополнительные компоненты Техника автоматизации Автоматизация и безопасность зданий Низковольтная коммутационная техника Технология безопасности Системные решения и продукты для отраслей Сервис ... и все, что Вам еще необходимо




  © ООО "СК ЭНЕРГО" 2007-2022
  (4872) 700-366  skenergo@mail.ru
Яндекс.Метрика