General information | | | | |
Product type designation | PS405, 24/48/60 VDC, 5 VDC/10 A | PS405,24/48/60 VDC,5 VDC/10 A,RED | | PS407,UC 120/230 V,5 VDC/10 A,RED. |
Supply voltage | | | | |
Rated value (DC) | | | | |
| Yes | Yes | | |
| Yes | Yes | | |
| Yes | Yes | | |
| | | Yes | Yes |
| | | Yes | Yes |
permissible range, lower limit (DC) | 19.2 V; Dynamic 18.5 V | 19.2 V; Dynamic 18.5 V | 88 V | 88 V |
permissible range, upper limit (DC) | 72 V; dynamic 75.5 V | 72 V; dynamic 75.5 V | 300 V | 300 V |
Rated value (AC) | | | | |
| | | Yes | Yes |
| | | Yes | Yes |
permissible range, lower limit (AC) | | | 85 V | 85 V |
permissible range, upper limit (AC) | | | 264 V | 264 V |
Line frequency | | | | |
| | | Yes | Yes |
| | | Yes | Yes |
| | | 47 Hz | 47 Hz |
| | | 63 Hz | 63 Hz |
Mains buffering | | | | |
| 20 ms | 20 ms | 20 ms | 20 ms |
| Yes | Yes | Yes | Yes |
Input current | | | | |
Rated value at 24 V DC | 4 A | 4 A | | |
Rated value at 48 V DC | 2 A | 2 A | | |
Rated value at 60 V DC | 1.6 A | 1.6 A | | |
Rated value at 110 V DC | | | 1 A; at 120 V DC | 1 A; at 120 V DC |
Rated value at 230 V DC | | | 0.5 A | 0.5 A |
Rated value at 120 V AC | | | 0.9 A | 0.9 A |
Rated value at 230 V AC | | | 0.5 A | 0.5 A |
Inrush current, max. | 18 A; Full width at half maximum 20 ms | 18 A; Full width at half maximum 20 ms | 63 A; Full width at half maximum 1 ms | 63 A; Full width at half maximum 1 ms |
Output voltage | | | | |
Type of output voltage | DC | DC | DC | |
Rated value (DC) | | | | |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
Output current | | | | |
for backplane bus (5 V DC), max. | 10 A; 7A @ > 60 °C, no base load necessary | 10 A; no base load required | 10 A; no base load required | 10 A; no base load required |
for backplane bus (24 V DC), max. | 1 A; idling-proof | 1 A; idling-proof | 1 A; idling-proof | 1 A; idling-proof |
short-circuit protection | Yes | Yes | Yes | Yes |
Power | | | | |
Power consumption, typ. | 95 W | 95 W | 95 W | 95 W |
Power loss | | | | |
Power loss, typ. | 20 W | 20 W | 20 W | 20 W |
Battery | | | | |
Backup battery | | | | |
| Yes; 2x lithium AA; 3.6 V / 2.3 Ah | Yes; 0 °C to +60 °C: 2 x lithium AA; 3.6 V/2.3 Ah // -25 °C to +70 °C and/or 100% RH: 2 x external battery box 6AG1971-0AA00-7AA0 and 2 x MONO cell design D | Yes; 0 °C to +60 °C: 2 x lithium AA; 3.6 V/2.3 Ah // -25 °C to +70 °C and/or 100% RH: 2 x external battery box 6AG1971-0AA00-7AA0 and 2 x MONO cell design D | Yes; 0 °C to +60 °C: 2 x lithium AA; 3.6 V/2.3 Ah // -25 °C to +70 °C and/or 100% RH: 2 x external battery box 6AG1971-0AA00-7AA0 and 2 x MONO cell design D |
Hardware configuration | | | | |
Slots | | | | |
| 2 | 2 | 2 | 2 |
Potential separation | | | | |
primary/secondary | Yes | Yes | Yes | Yes |
EMC | | | | |
Compliance with line harmonic distortion limits | | | | |
| | | Yes | Yes |
Degree and class of protection | | | | |
Protection class | 1; with protective conductor | 1; with protective conductor | 1; with protective conductor | 1; with protective conductor |
Ambient conditions | | | | |
Ambient temperature during operation | | | | |
| -25 °C; = Tmin | -25 °C; = Tmin; using the external battery box SIPLUS 6AG1971-0AA00-7AA0 for buffer mode | -25 °C; using the external battery box SIPLUS 6AG1971-0AA00-7AA0 for buffer mode | -25 °C; using the external battery box SIPLUS 6AG1971-0AA00-7AA0 for buffer mode |
| 70 °C; = Tmax | 70 °C; = Tmax; using the external battery box SIPLUS 6AG1971-0AA00-7AA0 for buffer mode | 70 °C; using the external battery box SIPLUS 6AG1971-0AA00-7AA0 for buffer mode | 70 °C; using the external battery box SIPLUS 6AG1971-0AA00-7AA0 for buffer mode |
Extended ambient conditions | | | | |
| Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m) | Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m) | Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m) | Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) |
Relative humidity | | | | |
| 100 %; Relative humidity, incl. condensation / frost permitted (no commissioning under condensation conditions) | 100 %; RH incl. condensation/frost (no commissioning if there is condensation). In buffer mode, use battery box SIPLUS 6AG1971-0AA00-7AA0 for high humidity | 100 %; RH incl. condensation/frost (no commissioning if there is condensation). In buffer mode, use battery box SIPLUS 6AG1971-0AA00-7AA0 for high humidity | 100 %; RH incl. condensation/frost (no commissioning if there is condensation). In buffer mode, use battery box SIPLUS 6AG1971-0AA00-7AA0 for high humidity |
Resistance | | | | |
| Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation in corrosive atmospheres! | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation! |
| Yes; Class 3C4 incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation! |
| Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! |
Connection method | | | | |
Connecting cables/cross-sections | 3x 1.5 mm?, solid or stranded wire with end sleeve, external diameter 3 mm to 9 mm | 3x 1.5 mm?, solid or stranded wire with end sleeve, external diameter 3 mm to 9 mm | 3x 1.5 mm?, solid or stranded wire with end sleeve, external diameter 3 mm to 9 mm | 3x 1.5 mm?, solid or stranded wire with end sleeve, external diameter 3 mm to 9 mm |
Dimensions | | | | |
Width | 50 mm | 50 mm | 50 mm | 50 mm |
Height | 290 mm | 290 mm | 290 mm | 290 mm |
Depth | 217 mm | 217 mm | 217 mm | 217 mm |
Weights | | | | |
Weight, approx. | 1.2 kg | 1 200 g | 1 200 g | 1 200 g |