Line voltages | 380 … 480 V 3 AC, ±10 % (-15 % < 1 min) 500 … 690 V 3 AC, ±10 % (-15 % < 1 min) |
Line supply types | Grounded TN/TT systems and non-grounded IT systems |
Line frequency | 47 … 63 Hz |
Output frequency 1) | |
| 0 … 650 Hz |
| 0 … 600 Hz |
| 0 … 600 Hz |
Line power factor Fundamental | |
| > 0.96 |
| > 0.96 |
| Adjustable (factory-set to cos ? = 1) |
Efficiency | |
| > 99.0 % |
| > 98.5 % |
| > 97.5 % (including Active Interface Module) |
| > 98.5 % |
Overvoltage category | III to EN 61800?5?1 |
Control method | Vector/servo control with and without encoder or V/f control |
Fixed speeds | 15 fixed speeds plus 1 minimum speed, parameterizable (in the default setting, 3 fixed setpoints plus 1 minimum speed are selectable using terminal block/PROFIBUS/PROFINET) |
Skipped speed ranges | 4, parameterizable |
Setpoint resolution | 0.001 rpm digital (14 bit + sign) 12 bit analog |
Braking operation | With Active Line Modules and Smart Line Modules, four-quadrant operation as standard (energy recovery). With Basic Line Modules, single-quadrant operation as standard. Braking when the power fails using an optional braking module. |
Mechanical specifications |
Degree of protection | IP20 (higher degrees of protection up to IP54 optional) |
Protection class | I acc. to EN 61800?5?1 |
Touch protection | EN 50274/BGV A3 for the intended purpose |
Cabinet system | Rittal TS 8, doors with double-barb lock, three-section base plates for cable entry |
Paint finish | RAL 7035 (indoor requirements) |
Type of cooling | Forced air cooling AF to EN 60146 |
Ambient conditions | Storage 2) | Transport 2) | Operation |
Ambient temperature | -25 ... +55 °C | -25 ... +70 °C from -40 °C3) for 24 hours | 0 ... +40 °C to +50 °C, see derating data |
Relative humidity (condensation not permissible) | 5 ... 95 % 3) Class 1K4 acc. to IEC 60721?3?1 | 5 ... 95 % at 40 °C Class 2K3 acc. to IEC 60721?3?2 | 5 ... 95 % 3) Class 3K3 acc. to IEC 60721?3?3 |
Environmental class/harmful chemical substances | Class 1C2 acc. to EN 60721?3?1 | Class 2C2 acc. to EN 60721?3?2 | Class 3C2 acc. to EN 60721?3?3 |
Organic/biological influences | Class 1B1 acc. to EN 60721?3?1 | Class 2B1 acc. to EN 60721?3?2 | Class 3B1 acc. to EN 60721?3?3 |
Degree of pollution | 2 acc. to EN 61800?5?1 | 2 acc. to EN 61800?5?1 | 2 acc. to EN 61800?5?1 |
Installation altitude | Cabinet Modules, chassis format: up to 2000 m above sea level, without derating, > 2000 m, see characteristic curves/derating data For Motor Modules Booksize Cabinet Kit format as well as Central Braking Modules: up to 1000 m above sea level without derating, > 1000 m, see characteristic curves/derating data |
Mechanical stability | Storage 2) | Transport 2) | Operation |
Vibration load | Class 1M1 acc. to EN 60721?3?1 | Class 2M1 acc. to EN 60721?3?2 | – |
| 1.5 mm at 5 ... 9 Hz | 3.1 mm at 5 ... 9 Hz | 0.075 mm at 10 ... 58 Hz |
| 5 m/s? at > 9 ... 200 Hz | 10 m/s? at > 9 ... 200 Hz | 9.8 m/s? at > 58 ... 200 Hz |
Shock load | Class 1M1 acc. to EN 60721?3?1 | Class 2M1 acc. to EN 60721?3?2 | Class 3M1 acc. to EN 60721?3?3 |
| 40 m/s? at 22 ms | 100 m/s? at 11 ms | 100 m/s? at 11 ms |
Compliance with standards |
Conformances/approvals, according to | CE (EMC Directive No. 2004/108/EC and Low-Voltage Directive No. 2006/95/EC) |
Radio interference suppression | SINAMICS drive converter systems are not designed for connection to the public network (first environment). Radio interference suppression is compliant with the EMC product standard for variable-speed drives EN 61800-3, "Second environment" (industrial line supplies). The equipment can cause electromagnetic interference when it is connected to the public network. However, if supplementary measures are taken (e.g. > line filter), it can also be operated in the "first environment". |