Measuring instrument D-R 220
|
|
|
Measurements
|
|
|
Measuring ranges
|
|
|
|
0 ... 25/50/100 %
|
|
|
0 ... 0.2/0.4 ... 1.6
|
|
|
- 0 ... 160 mg/m3
- 0 ... 4 000 mg/m3
|
|
Measuring principle
|
Transmission
|
|
Sample gas temperature
|
Above dew point up to 200 °C, optional up to 500 °C
|
|
Sample gas pressure
|
-50 ... +10 hPa, optional higher
|
|
Duct diameter
|
0.4 ... 10 m
|
|
Ambient temperature
|
-20 ... +50 °C
|
|
Degree of protection
|
IP65
|
|
Measured value output
|
0/4 ... 20 mA, 400 ?
|
|
Digital outputs
|
2 relay outputs, 30 VA, max. 48 V/0.5 A
|
|
Digital inputs
|
None
|
|
Accuracy
|
< 2 % of the measuring range
|
|
Detection limit
|
< 2 % of the measuring range
|
|
Supply voltage
|
24 VDC, 0.4 A from the supply unit
|
|
Dimensions (H x W x D) measuring head
|
160 x 150 x 314 mm
|
|
Weight
|
|
|
|
2.7 kg
|
|
|
1.6 kg
|
|
Supply box
|
|
|
Purge air supply
|
From the supply box
|
|
Supply voltage
|
85 ... 264 VAC, 46 ... 63 Hz, 50 VA
|
|
Dimensions (H x W x D)
|
210 x 300 x 380 mm
|
|
Weight
|
13 kg
|
|
Degree of protection
|
IP65
|