Type
|
|
6FE1021-3CM10-1AA0
|
6FE1021-3CM10-2AA0
|
6FE1021-3CM10-3AA0
|
Product brand name
|
|
SIPLUS ECC2000
|
|
|
Product description
|
|
CM-230 managed version
|
CM-230 standalone version
|
CM-230-C standalone version
|
General data
|
|
|
Charging current
typical
|
A
|
16
|
|
|
Settable charging current
|
A
|
6 … 80
|
|
|
Product function
Load management
|
|
yes
|
|
|
Product description
|
|
Activation and monitoring of the energy-related components in the loading station, use in the communication with the electric vehicle in accordance with IEC61851
|
Suitability for use
|
|
Simple / complex AC charging systems
|
Standard
for electric vehicle charging mode
|
|
IEC / ISO 61851
|
|
|
Standard
for safety
|
|
according to IEC 61010-1 / EN 61010-1 (2nd edition) or UL61010-1 (2nd edition)
|
IP degree of protection
on the front
|
|
IP20
|
|
|
Degree of pollution
|
|
3, according to IEC/EN 61010-1
|
|
|
Type of the sensor
|
|
Humidity/temperature
|
|
--
|
Insulation voltage
with pollution degree 3
Rated value
|
V
|
230
|
|
|
Supply voltage
|
|
|
Type of voltage
of supply voltage
|
|
DC
|
|
|
Supply voltage
|
|
|
|
V
|
24
|
|
|
|
V
|
18 … 28
|
|
|
Current consumption
at rated value of supply voltage
|
mA
|
300
|
|
|
Communications
|
|
|
|
|
Product function
Bus communication
|
|
yes
|
|
|
Type of data transmission
to control system
|
|
Ethernet
|
|
|
Protocol
supported
|
|
|
- Vehicle communication according to IEC 61851
|
|
yes
|
|
|
|
|
yes
|
|
|
|
|
--
|
|
|
Display
|
|
|
Number of LEDs
|
|
1
|
|
|
Display version
|
|
|
|
|
green, flashing / permanently lit, waiting for EF / charging process active
|
- as status display of the inputs/outputs
|
|
--
|
orange, flashing (1 Hz / 5 Hz), device waiting for enable / preheat charging pole
|
|
|
red, flashing / abruptly flashing, error (see operating instructions)
|
Inputs/outputs
|
|
|
Number of interfaces
according to IEC 61851
|
|
1
|
|
|
Number of digital inputs
|
|
8
|
|
|
Type of voltage
of input voltages
|
|
DC
|
|
|
Input voltage
|
V
|
0 … 28
|
|
|
Number of digital outputs
|
|
9
|
8
|
|
Type of voltage
of output voltages
|
|
DC
|
|
|
Output voltage
|
V
|
18 … 28
|
|
|
Output current
at digital output
with <1> signal
Rated value
|
A
|
0,3
|
|
|
Property of output
Short-circuit proof
|
|
yes
|
|
|
Product function
Activation of cable grip
|
|
yes
|
|
|
|
|
24 V (solenoid)
|
|
|
Auxiliary circuit
|
|
|
Number of NO contacts
for auxiliary contacts
|
|
8
|
|
|
Operating current
of auxiliary contacts
|
|
|
|
A
|
0,75
|
|
|
|
A
|
0,75
|
|
|
|
A
|
1
|
|
|
Terminals
|
|
|
Contact assignment
|
|
|
|
|
L+24 V: 24 V DC connection (SELV)
|
|
|
|
|
M: 24 V DC connection (SELV)
|
|
|
Contact assignment
|
|
|
|
|
FE: Functional grounding (part of the vehicle interface, connection to connector according to IEC 61851)
|
|
|
PX: Proximity (part of the vehicle interface, connection to connector according to IEC 61851)
|
|
|
CP: Control pilot (part of the vehicle interface, connection to connector according to IEC 61851)
|
Contact assignment
|
|
|
|
|
1L: Root R1 ... R4
|
|
|
|
|
R1: Relay Output 1
|
R1 (P): Relay for enabling power outlet
|
|
|
R2: Relay Output 2
|
R2 (V): Fan relay
|
|
|
|
R3: Relay Output 3
|
R3 (H): Interlock relay
|
|
|
|
R4: Relay Output 4
|
R4 (S): Signaling relay
|
|
Contact assignment
|
|
|
|
|
2L: Root R5 ... R8
|
|
|
|
|
R5: Relay Output 5
|
R5 (HT): Heating relay
|
R5 (P): Relay Output 5
|
|
|
R6: Relay Output 6
|
|
|
|
|
R7: Relay Output 7
|
|
|
|
|
R8: Relay Output 8
|
|
|
Contact assignment
|
|
|
|
|
24 V: Infeed for 24 V outputs TR, O1 ... O8
|
24 V: Infeed for 24 V outputs O1 ... O8
|
|
|
|
TR: Trip, 24 V output
|
Not used
|
|
|
|
RX: Receive line (RS 232)
|
|
|
|
|
TX: Transmit line (RS 232)
|
|
|
|
|
1M: 24 V DC minus (SELV/PELV)
|
|
|
|
|
24 V: 24 V DC plus (SELV/PELV) connection
|
Contact assignment
|
|
|
|
|
O1: 24 V switching output 1
|
O1 (RC): 24 V switching output status charging output (Ready to Charge)
|
|
|
O2: 24 V switching output 2
|
O2 (E): 24 V switching output Error status
|
|
|
O3: 24 V switching output 3
|
O3 (CS): 24 V switching output Cable connected status
|
|
|
O4: 24 V switching output 4
|
O4 (V): 24 V switching output Vehicle connected status
|
|
|
O5: 24 V switching output 5
|
O5 (VC): 24 V switching output Charging status (Vehicle Charging)
|
|
|
O6: 24 V switching output 6
|
|
|
|
|
O7: 24 V switching output 7
|
|
|
|
|
O8: 24 V switching output 8
|
|
|
|
|
3M: Reference point 24 V outputs O1 ... O8
|
Contact assignment
|
|
|
|
|
I1: 24 V input 1
|
|
|
|
|
I2: 24 V input 2
|
I2 (HL): 24 V input status circuit breaker
|
|
|
I3: 24 V input 3
|
I3 (LS): 24 V input status circuit breaker
|
|
|
I4: 24 V input 4
|
I3 (FI): 24 V input RCCB status
|
|
|
I5: 24 V input 5
|
I4 (EO): 24 V input emergency unlocking
|
|
|
I6: 24 V input 6
|
|
|
|
|
I7: 24 V input 7
|
|
|
|
|
I8: 24 V input 8
|
|
|
|
|
2M: Reference point 24 V inputs I1 ... I8
|
Contact assignment
|
|
|
|
|
RJ45: Ethernet 10/100
|
|
|
Environmental conditions
|
|
|
Installation altitude
at height above sea level
maximum
|
m
|
2 000
|
|
|
Ambient temperature
|
|
|
|
°C
|
-25 … +70
|
|
|
|
°C
|
-25 … +55
|
|
|
|
°C
|
-25 … +70
|
|
|
Relative humidity
|
|
|
|
%
|
0 … 95
|
|
|
Electromagnetic compatibility
|
|
|
EMC interference emission
according to IEC 61000-6-3
|
|
suitable for use in residential areas, public areas and industry
|
EMC immunity
according to IEC 61000-6-2
|
|
suitable for operation in industrial and residential areas
|
Conducted interference BURST
according to IEC 61000-4-4
|
|
2 kV / 5 kHz DC supply lines, 1 kV / 5 kHz control lines, relay outputs, RS 232 and Ethernet, evaluation criterion B
|
Conducted interference SURGE
according to IEC 61000-4-5
|
|
Asymmetrical: DC supply lines 0.5 kV / 12 ohm; control lines, functional grounding, RS 232 interface 1 kV / 42 ohm; relay outputs 2 kV / 12 ohm; Ethernet line (shield) 1 kV direct; evaluation criterion B. Symmetrical: DC supply lines 0.5 kV / 2 ohm; evaluation criterion B
|
Field-based interference
according to IEC 61000-4-3
|
|
80 MHz ... 1 GHz 10 V/m, modulation 80% AM with 1 kHz, evaluation criterion B; 80 MHz ... 1.0 GHz 3 V/m, 1.4 ... 2.0 GHz 3 V/m, 2.0 ... 2.7 GHz 1 V/m, modulation 80% AM with 1 kHz, evaluation criterion A
|
Electrostatic discharging
according to IEC 61000-4-2
|
|
4 kV contact discharging / 8 kV air discharging, evaluation criterion B
|
Shock resistance
|
|
|
- According to IEC 60068-2-27
|
|
15 g / 11 ms / 3 shocks / axis
|
|
|
- During transport according to IEC 60068-2-29
|
|
1000 shocks / axis, 25 g, 6 ms half sine
|
Vibration resistance
|
|
|
|
|
5 ... 8.4 Hz / 3.5 mm deflection, 8.4 ... 500 Hz / 1 g
|
|
|
5 ... 8.4 Hz / 3.5 mm deflection, 8.4 ... 150 Hz / 1 g
|
Conducted interference as high frequency radiation
according to IEC 61000-4-6
|
|
3 V effective in frequency range 0.15 to 80 MHz, modulation 80 % AM with 1 kHz, evaluation criterion A
|
Immunity to magnetic fields with energy frequencies
in accordance with EN 61000-4-8
|
|
100 A/m at 50 Hz and 60 Hz, evaluation criterion A
|
Active power loss
total
typical
|
W
|
4
|
|
|
Protection against electric shock
|
|
Finger-safe
|
|
|
Contact reliability
|
|
80 000 operating cycles at 1 A, inductive load
|
Mounting/fastening/dimensions
|
|
|
|
|
Installation position
|
|
Vertical, on horizontal standard mounting rail
|
Material
of housing
|
|
Wellamid 6600-PA66-GV 30 HWV0CP
|
|
Lexan 915R
|
Type of mounting
|
|
Snap-on mounting on standard mounting rail TH 35 according to IEC 60715
|
Dimensions
|
|
|
|
mm
|
108
|
|
|
|
mm
|
91
|
|
|
|
mm
|
72
|
|
|
Connections
|
|
|
|
|
Electrical connection version
|
|
|
|
|
Combicon connection GMSTB 2.5
|
|
|
- for auxiliary and control circuit
|
|
Combicon connection MSTB 2.5
|
|
|
Type of pin assignment
|
|
|
|
|
Combicon connection MSTB 2.5
|
|
|
|
|
Combicon connection MSTB 2.5
|
|
|
Product function
Removable terminal for auxiliary and control circuit
|
|
yes
|
|
|
Connectable conductor cross section
|
|
|
|
mm?
|
0,5 … 2,5
|
|
|
|
|
|
- Without core ends prepared
|
mm?
|
0,5 … 2,5
|
|
|
|
mm?
|
0,5 … 2,5
|
|
|
AWG number
|
|
|
- As coded connectable conductor cross section
|
|
20 … 14
|
|
|
|