Type
|
|
5TT3200-1KK20
|
5TT3200-2KK20
|
5TT3200-3KK20
|
5TT3200-4KK20
|
5TT3200-6KK20
|
5TT3200-2KK30
|
Product brand name
|
|
SIPLUS ECC1000
|
Product description
|
|
CM-100
|
General data
|
|
|
|
|
|
|
|
Design of operator controls
of the charging station
|
|
Charging mode 3 according to IEC 61851
|
Product description
|
|
Activation and monitoring of the energy-related components in the loading station, use in the communication with the electric vehicle in accordance with IEC61851
|
Charging current
maximum
|
A
|
13
|
16
|
20
|
32
|
16
|
IP degree of protection
on the front
|
|
IP20
|
Degree of pollution
|
|
3, according to IEC/EN 61010-1
|
Insulation voltage
with pollution degree 3
Rated value
|
V
|
230
|
Supply voltage
|
|
|
|
|
|
|
|
Type of voltage
of supply voltage
|
|
AC
|
DC
|
Supply voltage
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
V
|
230
|
-
|
|
V
|
184 … 264
|
-
|
|
|
|
|
|
|
|
|
|
V
|
110
|
-
|
|
V
|
88 … 126
|
-
|
Supply voltage
|
|
|
|
|
|
|
|
|
V
|
-
|
24
|
|
V
|
-
|
18 … 28
|
Symmetrical tolerance of power frequency
|
|
|
|
|
|
|
|
|
Hz
|
47.5 … 52.5
|
-
|
|
Hz
|
57 … 63
|
-
|
Current consumption
at rated value of supply voltage
|
mA
|
100
|
300
|
Communications
|
|
|
|
|
|
|
|
Product function
Bus communication
|
|
No
|
Protocol
supported
|
|
|
|
|
|
|
|
- Vehicle communication according to IEC 61851
|
|
yes
|
|
|
No
|
|
|
No
|
Display
|
|
|
|
|
|
|
|
Number of LEDs
|
|
1
|
Display version
|
|
|
|
|
|
|
|
|
|
green, flashing / permanently lit, waiting for EF / charging process active
|
- as status display of the inputs/outputs
|
|
orange, flashing (1 Hz), device waiting for enable
|
|
|
red, flashing / abruptly flashing, error
|
Inputs/outputs
|
|
|
|
|
|
|
|
Number of interfaces
according to IEC 61851
|
|
1
|
Number of digital inputs
|
|
2
|
Type of voltage
of input voltages
|
|
DC
|
Input voltage
|
V
|
0 … 5
|
Number of digital outputs
|
|
0
|
Auxiliary circuit
|
|
|
|
|
|
|
|
Number of NO contacts
for auxiliary contacts
|
|
4
|
Operating current
of auxiliary contacts
|
|
|
|
|
|
|
|
|
A
|
0.75
|
|
A
|
0.75
|
|
A
|
1
|
Terminals
|
|
|
|
|
|
|
|
Contact assignment
|
|
|
|
|
|
|
|
|
|
L: 110/230 V AC connection
|
I+24 V: 24 V DC connection (SELV)
|
|
|
N: 110/230 V AC connection
|
M: 24 V DC connection (SELV)
|
Contact assignment
|
|
|
|
|
|
|
|
|
|
FE: Functional grounding (part of the vehicle interface, connection to connector according to IEC61851)
|
|
|
PX: Proximity (part of the vehicle interface, connection to connector according to IEC61851)
|
|
|
CP: Control Pilot (part of the vehicle interface, connection to connector according to IEC61851)
|
Contact assignment
|
|
|
|
|
|
|
|
|
|
AV: Auxiliary Voltage (read-back voltage for own digital inputs)
|
|
|
EN: Enable (digital input for module enable)
|
|
|
HL: Hatch Lock (digital input for cable grip status)
|
Contact assignment
|
|
|
|
|
|
|
|
|
|
P1: "Power" relay contact for switching the load contactor
|
P1: "Power" relay contact for switching the load contactor 13A branch
|
P1: "Power" relay contact for switching the load contactor
|
|
|
P2: "Power" relay contact for switching the load contactor
|
P2: "Power" relay contact for switching the load contactor 13A branch
|
P2: "Power" relay contact for switching the load contactor
|
|
|
V1: "Ventilation" relay contact for switching the fan
|
|
|
V2: "Ventilation" relay contact for switching the fan
|
|
|
H1: "Hatch" relay contact for switching the cable grip
|
|
|
H2: "Hatch" relay contact for switching the cable grip
|
|
|
S1: "Signal" relay contact for error signals
|
|
|
S2: "Signal" relay contact for error signals
|
Environmental conditions
|
|
|
|
|
|
|
|
Installation altitude
At height above sea level
maximum
|
m
|
2 000
|
Ambient temperature
|
|
|
|
|
|
|
|
|
°C
|
-25 … +70
|
|
°C
|
-25 … +60
|
|
°C
|
-25 … +70
|
Relative humidity
|
|
|
|
|
|
|
|
|
%
|
0 … 95
|
Electromagnetic compatibility
|
|
|
|
|
|
|
|
EMC interference emission
according to IEC 61000-6-3
|
|
suitable for use in residential areas, public areas and industry
|
EMC immunity
according to IEC 61000-6-2
|
|
suitable for operation in industrial and residential areas
|
Conducted interference BURST
according to IEC 61000-4-4
|
|
4 kV / 5 kHz AC supply lines and functional grounding, 2 kV / 5 kHz control lines and relay outputs
|
2 kV / 5 kHz DC supply lines, 2 kV / 5 kHz control lines and relay outputs
|
Conducted interference SURGE
according to IEC 61000-4-5
|
|
Asymmetrical: AC supply lines 4 kV / 12 ohm; control lines and functional grounding 2 kV / 42 ohm; relay outputs 4 kV / 12 ohm; evaluation criterion B. Symmetrical: AC supply lines 2 kV / 2 ohm, relay outputs 2 kV / 2 ohm; evaluation criterion B
|
Asymmetrical: DC supply lines 0.5 kV / 12 ohm; DC supply lines 1 kV / 42 ohm; control lines and functional grounding 2 kV / 42 ohm; relay outputs 4 kV / 12 ohm; evaluation criterion B. Symmetrical: DC supply lines 0.5 kV / 2 ohm; DC supply lines 1 kV / 42 ohm; relay outputs 2kV / 2 ohm; evaluation criterion B.
|
Field-based interference
according to IEC 61000-4-3
|
|
80 MHz to 1 GHz 10 V/m, 1.4 GHz to 2 GHz 3 V/m, 2 GHz to 2.7 GHz 1 V/m, evaluation criterion A
|
Electrostatic discharging
according to IEC 61000-4-2
|
|
4 kV contact discharging / 8 kV air discharging, evaluation criterion B
|
Shock resistance
|
|
|
|
|
|
|
|
- according to IEC 60068-2-27
|
|
15g / 11 ms / 3 shocks per axis
|
- during transport according to IEC 60068-2-29
|
|
1000 shocks / axis, 25g, 6 ms half sine
|
Vibration resistance
|
|
|
|
|
|
|
|
- during transport according to IEC 60068-2-6
|
|
5 to 8.4 Hz / 3.5 mm deflection, 8.4 to 500 Hz / 1g
|
- during operation according to IEC 60068-2-6
|
|
5 to 8.4 Hz / 3.5 mm deflection, 8.4 to 150 Hz / 1g
|
Impulse withstand voltage
Rated value
|
kV
|
4
|
Conducted interference as high frequency radiation
according to IEC 61000-4-6
|
|
3 V effective in frequency range 0.15 to 80 MHz, modulation 80 % AM with 1 kHz, evaluation criterion A
|
Immunity to magnetic fields with energy frequencies
in accordance with EN 61000-4-8
|
|
100 A/m at 50 Hz and 60 Hz, evaluation criterion A
|
Active power loss
total
typical
|
W
|
6
|
4
|
Protection against electric shock
|
|
Finger-safe
|
Contact reliability
|
|
80000 operating cycles at 1 A, inductive load
|
Mounting/fastening/dimensions
|
|
|
|
|
|
|
|
Installation position
|
|
Vertical, on horizontal standard mounting rail
|
Material
of housing
|
|
Wellamid 6600-PA66-GV 30 HWV0CP
|
Type of mounting
|
|
Snap-mounting on 35 mm standard mounting rail according to DIN EN 60715
|
Dimensions
|
|
|
|
|
|
|
|
|
mm
|
72
|
|
mm
|
91
|
|
mm
|
71
|
Connections
|
|
|
|
|
|
|
|
Electrical connection version
|
|
|
|
|
|
|
|
|
|
Combicon connection GMSTB 2.5
|
- for auxiliary and control circuit
|
|
Combicon connection MSTB 2.5
|
Type of pin assignment
|
|
|
|
|
|
|
|
|
|
Combicon connection MSTB 2.5
|
|
|
Combicon connection MSTB 2.5
|
Product function
Removable terminal for auxiliary and control circuit
|
|
yes
|
Connectable conductor cross section
|
|
|
|
|
|
|
|
|
mm?
|
0.5 … 2.5
|
|
|
|
|
|
|
|
|
- without core ends prepared
|
mm?
|
0.5 … 2.5
|
|
mm?
|
0.5 … 2.5
|
AWG number
|
|
|
|
|
|
|
|
- as coded connectable conductor cross section
|
|
20 … 14
|
|