| | | | | | | |
?
The most important directives and standards are listed below. These are used as basis for the SINAMICS S150 Converter Cabinet Units drive system and they must be carefully observed to achieve an EMC-compliant configuration that is safe both functionally and in operation.
European directives
|
2006/95/EG
|
Low-voltage directive: Legal guidelines of the EU member states concerning electrical equipment for use within specified voltage limits
|
2004/108/EG
|
EMC directive: Legal guidelines of the EU member states for electromagnetic compatibility
|
European standards
|
EN 954?1 1)
|
Safety of machinery – safety-related parts of control systems; Part 1: General design principles
|
EN ISO 13849?1
|
Safety of machinery – safety-related parts of control systems; Part 1: General design guidelines (ISO 13849-1: 2006) (replaces EN 954-1)
|
EN 60146?1?1
|
Semiconductor converters – General requirements and line-commutated converters Part 1-1: Specification of basic requirements
|
EN 60204?1
|
Safety of machinery – Electrical equipment of machines; Part 1: General requirements
|
EN 60529
|
Degrees of protection provided by enclosures (IP code)
|
EN 61508?1
|
Functional safety of electrical/electronic/programmable electronic safety-related systems Part 1: General requirements
|
EN 61800?2
|
Variable-speed electric drives Part 2: General requirements – Rating specifications for low-voltage adjustable frequency AC power drive systems
|
EN 61800?3
|
Variable-speed electric drives Part 3: EMC requirements including specific test methods
|
EN 61800?5?1
|
Adjustable-speed electrical power drive systems Part 5: Safety requirements Main section 1: Electrical and thermal requirements
|
EN 61800?5?2
|
Adjustable speed electrical power drive systems Part 5-2: Safety requirements – Functional safety (IEC 61800-5-2: 2007)
|
1) Will be replaced by EN ISO 13849-1 at the end of 2011.
General technical specifications
Electrical specifications
|
Line voltages
|
80 … 480 V 3 AC , ±10 % (-15 % < 1 min)
500 … 690 V 3 AC, ±10 % (-15 % < 1 min)
|
Line supply types
|
Grounded TN/TT systems and non-grounded IT systems
|
Line frequency
|
47 ... 63 Hz
|
Output frequency 1)
|
|
|
0 ... 650 Hz
|
|
0 ... 600 Hz
|
|
0 ... 600 Hz
|
Line power factor
|
Adjustable (factory-set to cos ? = 1)
|
Efficiency
|
> 96 %
|
Overvoltage category
|
III to EN 61800?5?1
|
Control method
|
Vector control with and without encoder or V/f control
|
Fixed speeds
|
15 fixed speeds plus 1 minimum speed, parameterizable (in the default setting, 3 fixed setpoints plus 1 minimum speed are selectable using terminal block/PROFIBUS/PROFINET)
|
Skipped speed ranges
|
4, parameterizable
|
Setpoint resolution
|
0.001 rpm digital (14 bits + sign) 12 bit analog
|
Braking operation
|
Four-quadrant operation is possible as standard (optional via a braking unit if braking is required when power fails)
|
Mechanical specifications
|
Degree of protection
|
IP20 (higher degrees of protection up to IP54 optional)
|
Protection class
|
I acc. to EN 61800?5?1
|
Touch protection
|
EN 50274 / BGV A3 for the intended purpose
|
Cabinet system
|
Rittal TS 8, doors with double-barb lock, three-section base plates for cable entry
|
Paint finish
|
RAL 7035 (indoor requirements)
|
Type of cooling
|
Forced air cooling AF to EN 60146
|
Ambient conditions
|
Storage 2)
|
Transport 2)
|
Operation
|
Ambient temperature
|
-25 ... +55 °C
|
-25 ... +70 °C
from -40 °C 3) for 24 hours
|
0 3) ... +40 °C
to +50 °C, see derating data
|
Relative humidity
(condensation not permissible)
|
5 ... 95 % 3)
Class 1K4 acc. to IEC 60721?3?1
|
5 ... 95 % at 40 °C
Class 2K3 acc. to IEC 60721?3?2
|
5 ... 95 % 3)
Class 3K3 acc. to IEC 60721?3?3
|
Environmental class/harmful chemical substances
|
Class 1C2 acc. to IEC 60721?3?1
|
Class 2C2 acc. to IEC 60721?3?2
|
Class 3C2 acc. to IEC 60721?3?3
|
Organic/biological influences
|
Class 1B1 acc. to IEC 60721?3?1
|
Class 2B1 acc. to IEC 60721?3?2
|
Class 3B1 acc. to IEC 60721?3?3
|
Degree of pollution
|
2 acc. to EN 61800?5?1
|
2 acc. to EN 61800?5?1
|
2 acc. to EN 61800?5?1
|
Installation altitude
|
Up to 2000 m above sea level, without derating, > 2000 m, see derating data
|
Mechanical stability
|
Storage 2)
|
Transport 2)
|
Operation
|
Vibration load
|
Class 1M2 acc. to IEC 60721?3?1
|
Class 2M2 acc. to IEC 60721?3?2
|
–
|
|
1.5 mm at 5 ... 9 Hz
|
3.1 mm at 5 ... 9 Hz
|
0.075 mm at 10 ... 58 Hz
|
|
5 m/s? at > 9 ... 200 Hz
|
10 m/s? at 9 ... 200 Hz
|
9.8 m/s2 at 58 ... 200 Hz
|
Shock load
|
Class 1M2 acc. to IEC 60721?3?1
|
Class 2M2 acc. to IEC 60721?3?2
|
Class 3M4 acc. to IEC 60721?3?3
|
|
40 m/s? at 22 ms
|
100 m/s? at 11 ms
|
100 m/s2 at 11 ms
|
Compliance with standards
|
Conformances/approvals, according to
|
CE (EMC Directive No. 2004/108/EC and Low-Voltage Directive No. 2006/95/EC)
|
Radio interference suppression
|
SINAMICS drive converter systems are not designed for connection to the public network (first environment). Radio interference suppression is compliant with the EMC product standard for variable-speed drives EN 61800-3, "Second environment" (industrial line supplies). The equipment can cause electromagnetic interference when it is connected to the public network. However, if supplementary measures are taken (e.g. > line filter), it can also be operated in the "first environment".
|
1) Please note:
- The correlation between the maximum output frequency, pulse frequency and current derating. Higher output frequencies for specific configurations are available on request.
- The correlation between the maximum output frequency and permissible output current (current derating).
Information is provided in the SINAMICS Low Voltage Engineering Manual.
2) In transport packaging.
3) Deviations with respect to the specified class are underlined.
Line voltage 380 … 480 V 3 AC
|
SINAMICS S150 Converter Cabinet Units
|
|
|
6SL3710-7LE32-1AA3
|
6SL3710-7LE32-6AA3
|
6SL3710-7LE33-1AA3
|
6SL3710-7LE33-8AA3
|
6SL3710-7LE35-0AA3
|
6SL3710-7LE36-1AA3
|
Type rating
|
|
|
|
|
|
|
|
|
kW
|
110
|
132
|
160
|
200
|
250
|
315
|
|
kW
|
90
|
110
|
132
|
160
|
200
|
250
|
|
hp
|
150
|
200
|
250
|
300
|
400
|
500
|
|
hp
|
150
|
200
|
200
|
250
|
350
|
350
|
Output current
|
|
|
|
|
|
|
|
|
A
|
210
|
260
|
310
|
380
|
490
|
605
|
|
A
|
205
|
250
|
302
|
370
|
477
|
590
|
|
A
|
178
|
233
|
277
|
340
|
438
|
460
|
|
A
|
307
|
375
|
453
|
555
|
715
|
885
|
Infeed/regenerative feedback current
|
|
|
|
|
|
|
|
|
A
|
197
|
242
|
286
|
349
|
447
|
549
|
- Max. input current Imax E
|
A
|
315
|
390
|
570
|
570
|
735
|
907
|
Current demand, max. 5)
|
|
|
|
|
|
|
|
- 24 V DC auxiliary power supply
|
A
|
Internal
|
Internal
|
Internal
|
Internal
|
Internal
|
Internal
|
Pulse frequency 6)
|
|
|
|
|
|
|
|
|
kHz
|
2
|
2
|
2
|
2
|
2
|
1.25
|
|
|
|
|
|
|
|
|
|
kHz
|
2
|
2
|
2
|
2
|
2
|
1.25
|
|
kHz
|
8
|
8
|
8
|
8
|
8
|
7.5
|
Power loss, max. 7)
|
|
|
|
|
|
|
|
|
kW
|
6.31
|
7.55
|
10.01
|
10.72
|
13.13
|
17.69
|
|
kW
|
6.49
|
7.85
|
10.45
|
11.15
|
13.65
|
18.55
|
Cooling air requirement
|
m3/s
|
0.58
|
0.7
|
1.19
|
1.19
|
1.19
|
1.96
|
Sound pressure level LpA
(1 m) at 50/60 Hz
|
dB
|
71/73
|
71/73
|
72/74
|
72/74
|
72/74
|
77/79
|
Cable length, max.
|
|
|
|
|
|
|
|
|
m
|
300
|
300
|
300
|
300
|
300
|
300
|
|
m
|
450
|
450
|
450
|
450
|
450
|
450
|
Degree of protection
|
|
IP20
|
IP20
|
IP20
|
IP20
|
IP20
|
IP20
|
Dimensions
|
|
|
|
|
|
|
|
|
mm
|
1400
|
1400
|
1600
|
1800
|
1800
|
2200
|
|
mm
|
2000
|
2000
|
2000
|
2000
|
2000
|
2000
|
|
mm
|
600
|
600
|
600
|
600
|
600
|
600
|
Weight, approx.
|
kg
|
708
|
708
|
892
|
980
|
980
|
1716
|
Frame size
|
|
F
|
F
|
G
|
G
|
G
|
H
|
Note: The power data in hp units are based on the NEC/CEC standards for the North American market.
Information about line supply connections, motor connections and cabinet grounding can be found under
Cable cross-sections and connections
.
1) Rated power of a typ. 6-pole standard induction motor based on IL or IH with 400 V 3 AC 50 Hz.
2) Rated power of a typ. 6-pole standard induction motor based on IL or IH with 460 V 3 AC 60 Hz.
3) The base load current IL is the basis for a duty cycle of 110 % for 60 s or 150 % for 10 s with a duty cycle duration of 300 s.
4) The base load current IH is the basis for a duty cycle of 150 % for 60 s or 160 % for 10 s with a duty cycle duration of 300 s.
5) If the drive closed-loop control is still to remain active when the line supply fails, then the equipment must be provided with an external 24 V DC supply.
6)
Information regarding the correlation between the pulse frequency and max. output current/output frequency is provided in the SINAMICS Low Voltage Engineering Manual.
7) The specified power losses are the maximum values at 100 % utilization. The values are lower under normal operating conditions.
Line voltage 380 … 480 V 3 AC
|
SINAMICS S150 Converter Cabinet Units
|
|
|
6SL3710-7LE37-5AA3
|
6SL3710-7LE38-4AA3
|
6SL3710-7LE41-0AA3
|
6SL3710-7LE41-2AA3
|
6SL3710-7LE41-4AA3
|
Type rating
|
|
|
|
|
|
|
|
kW
|
400
|
450
|
560
|
710
|
800
|
|
kW
|
315
|
400
|
450
|
560
|
710
|
|
hp
|
600
|
700
|
800
|
900
|
1150
|
|
hp
|
450
|
600
|
700
|
900
|
1000
|
Output current
|
|
|
|
|
|
|
|
A
|
745
|
840
|
985
|
1260
|
1405
|
|
A
|
725
|
820
|
960
|
1230
|
1370
|
|
A
|
570
|
700
|
860
|
1127
|
1257
|
|
A
|
1087
|
1230
|
1440
|
1845
|
2055
|
Infeed/regenerative feedback current
|
|
|
|
|
|
|
|
A
|
674
|
759
|
888
|
1133
|
1262
|
- Max. input current Imax E
|
A
|
1118
|
1260
|
1477
|
1891
|
2107
|
Current demand, max. 5)
|
|
|
|
|
|
|
- 24 V DC auxiliary power supply
|
A
|
Internal
|
Internal
|
Internal
|
Internal
|
Internal
|
Pulse frequency 6
|
|
|
|
|
|
|
|
kHz
|
1.25
|
1.25
|
1.25
|
1.25
|
1.25
|
|
|
|
|
|
|
|
|
kHz
|
1.25
|
1.25
|
1.25
|
1.25
|
1.25
|
|
kHz
|
7.5
|
7.5
|
7.5
|
7.5
|
7.5
|
Power loss, max. 7)
|
|
|
|
|
|
|
|
kW
|
20.63
|
21.1
|
27.25
|
33.05
|
33.95
|
|
kW
|
21.75
|
22.25
|
28.65
|
34.85
|
35.85
|
Cooling air requirement
|
m3/s
|
1.96
|
1.96
|
2.6
|
2.6
|
2.6
|
Sound pressure level LpA
(1 m) at 50/60 Hz
|
dB
|
77/79
|
77/79
|
77/79
|
78/80
|
78/80
|
Cable length, max.
|
|
|
|
|
|
|
|
m
|
300
|
300
|
300
|
300
|
300
|
|
m
|
450
|
450
|
450
|
450
|
450
|
Degree of protection
|
|
IP20
|
IP20
|
IP20
|
IP20
|
IP20
|
Dimensions
|
|
|
|
|
|
|
|
mm
|
2200
|
2200
|
2800
|
2800
|
2800
|
|
mm
|
2000
|
2000
|
2000
|
2000
|
2000
|
|
mm
|
600
|
600
|
600
|
600
|
600
|
Weight, approx.
|
kg
|
1731
|
1778
|
2408
|
2408
|
2408
|
Frame size
|
|
H
|
H
|
J
|
J
|
J
|
Note: The power data in hp units are based on the NEC/CEC standards for the North American market.
Information about line supply connections, motor connections and cabinet grounding can be found under
Cable cross-sections and connections
.
1) Rated power of a typ. 6-pole standard induction motor based on IL or IH with 400 V 3 AC 50 Hz.
2) Rated power of a typ. 6-pole standard induction motor based on IL or IH with 460 V 3 AC 60 Hz.
3) The base load current IL is the basis for a duty cycle of 110 % for 60 s or 150 % for 10 s with a duty cycle duration of 300 s.
4) The base load current IH is the basis for a duty cycle of 150 % for 60 s or 160 % for 10 s with a duty cycle duration of 300 s.
5) If the drive closed-loop control is still to remain active when the line supply fails, then the equipment must be provided with an external 24 V DC supply.
6)
Information regarding the correlation between the pulse frequency and max. output current/output frequency is provided in the SINAMICS Low Voltage Engineering Manual.
7) The specified power losses are the maximum values at 100 % utilization. The values are lower under normal operating conditions.
Line voltage 500 … 690 V 3 AC 50 Hz
|
SINAMICS S150 Converter Cabinet Units
|
|
|
6SL3710-7LG28-5AA3
|
6SL3710-7LG31-0AA3
|
6SL3710-7LG31-2AA3
|
6SL3710-7LG31-5AA3
|
6SL3710-7LG31-8AA3
|
6SL3710-7LG32-2AA3
|
Type rating
|
|
|
|
|
|
|
|
|
kW
|
75
|
90
|
110
|
132
|
160
|
200
|
|
kW
|
55
|
75
|
90
|
110
|
132
|
160
|
|
kW
|
55
|
55
|
75
|
90
|
110
|
132
|
|
kW
|
45
|
55
|
75
|
90
|
90
|
110
|
|
hp
|
75
|
75
|
100
|
150
|
150
|
200
|
|
hp
|
75
|
75
|
100
|
125
|
150
|
200
|
Output current
|
|
|
|
|
|
|
|
|
A
|
85
|
100
|
120
|
150
|
175
|
215
|
|
A
|
80
|
95
|
115
|
142
|
170
|
208
|
|
A
|
76
|
89
|
117
|
134
|
157
|
192
|
|
A
|
120
|
142
|
172
|
213
|
255
|
312
|
Infeed/regenerative feedback current
|
|
|
|
|
|
|
|
|
A
|
86
|
99
|
117
|
144
|
166
|
202
|
- Max. input current Imax E
|
A
|
125
|
144
|
170
|
210
|
253
|
308
|
Current demand, max. 5)
|
|
|
|
|
|
|
|
- 24 V DC auxiliary power supply
|
A
|
Internal
|
Internal
|
Internal
|
Internal
|
Internal
|
Internal
|
Pulse frequency 6
|
|
|
|
|
|
|
|
|
kHz
|
1.25
|
1.25
|
1.25
|
1.25
|
1.25
|
1.25
|
|
|
|
|
|
|
|
|
|
kHz
|
1.25
|
1.25
|
1.25
|
1.25
|
1.25
|
1.25
|
|
kHz
|
7.5
|
7.5
|
7.5
|
7.5
|
7.5
|
7.5
|
Power loss, max. 7)
|
|
|
|
|
|
|
|
|
kW
|
5.12
|
5.38
|
5.84
|
5.75
|
11.02
|
11.44
|
|
kW
|
4.45
|
4.65
|
5.12
|
4.97
|
11.15
|
11.56
|
Cooling air requirement
|
m3/s
|
0.58
|
0.58
|
0.58
|
0.58
|
1.19
|
1.19
|
Sound pressure level LpA
(1 m) at 50/60 Hz
|
dB
|
71/73
|
71/73
|
71/73
|
71/73
|
75/77
|
75/77
|
Cable length, max.
|
|
|
|
|
|
|
|
|
m
|
300
|
300
|
300
|
300
|
300
|
300
|
|
m
|
450
|
450
|
450
|
450
|
450
|
450
|
Degree of protection
|
|
IP20
|
IP20
|
IP20
|
IP20
|
IP20
|
IP20
|
Dimensions
|
|
|
|
|
|
|
|
|
mm
|
1400
|
1400
|
1400
|
1400
|
1600
|
1600
|
|
mm
|
2000
|
2000
|
2000
|
2000
|
2000
|
2000
|
|
mm
|
600
|
600
|
600
|
600
|
600
|
600
|
Weight, approx.
|
kg
|
708
|
708
|
708
|
708
|
892
|
892
|
Frame size
|
|
F
|
F
|
F
|
F
|
G
|
G
|
Note: The power data in hp units are based on the NEC/CEC standards for the North American market.
Information about line supply connections, motor connections and cabinet grounding can be found under
Cable cross-sections and connections
.
1) Rated power of a typ. 6-pole standard induction motor based on IL or IH with 500 V or 690 V 3 AC 50 Hz.
2) Rated power of a typ. 6-pole standard induction motor based on IL or IH with 575 V 3 AC 60 Hz.
3) The base load current IL is the basis for a duty cycle of 110 % for 60 s or 150 % for 10 s with a duty cycle duration of 300 s.
4) The base load current IH is the basis for a duty cycle of 150 % for 60 s or 160 % for 10 s with a duty cycle duration of 300 s.
5) If the drive closed-loop control is still to remain active when the line supply fails, then the equipment must be provided with an external 24 V DC supply.
6)
Information regarding the correlation between the pulse frequency and max. output current/output frequency is provided in the SINAMICS Low Voltage Engineering Manual.
7) The specified power losses are the maximum values at 100 % utilization. The values are lower under normal operating conditions.
Line voltage 500 … 690 V 3 AC 50 Hz
|
SINAMICS S150 Converter Cabinet Units
|
|
|
6SL3710-7LG32-6AA3
|
6SL3710-7LG33-3AA3
|
6SL3710-7LG34-1AA3
|
6SL3710-7LG34-7AA3
|
6SL3710-7LG35-8AA3
|
6SL3710-7LG37-4AA3
|
Type rating
|
|
|
|
|
|
|
|
|
kW
|
250
|
315
|
400
|
450
|
560
|
710
|
|
kW
|
200
|
250
|
315
|
400
|
450
|
630
|
|
kW
|
160
|
200
|
250
|
315
|
400
|
500
|
|
kW
|
132
|
160
|
200
|
250
|
315
|
450
|
|
hp
|
250
|
300
|
400
|
450
|
600
|
700
|
|
hp
|
200
|
250
|
350
|
450
|
500
|
700
|
Output current
|
|
|
|
|
|
|
|
|
A
|
260
|
330
|
410
|
465
|
575
|
735
|
|
A
|
250
|
320
|
400
|
452
|
560
|
710
|
|
A
|
233
|
280
|
367
|
416
|
514
|
657
|
|
A
|
375
|
480
|
600
|
678
|
840
|
1065
|
Infeed/regenerative feedback current
|
|
|
|
|
|
|
|
|
A
|
242
|
304
|
375
|
424
|
522
|
665
|
- Max. input current Imax E
|
A
|
370
|
465
|
619
|
700
|
862
|
1102
|
Current demand, max. 5)
|
|
|
|
|
|
|
|
- 24 V DC auxiliary power supply
|
A
|
Internal
|
Internal
|
Internal
|
Internal
|
Internal
|
Internal
|
Pulse frequency 6
|
|
|
|
|
|
|
|
|
kHz
|
1.25
|
1.25
|
1.25
|
1.25
|
1.25
|
1.25
|
|
|
|
|
|
|
|
|
|
kHz
|
1.25
|
1.25
|
1.25
|
1.25
|
1.25
|
1.25
|
|
kHz
|
7.5
|
7.5
|
7.5
|
7.5
|
7.5
|
7.5
|
Power loss, max. 7)
|
|
|
|
|
|
|
|
|
kW
|
11.97
|
12.69
|
19.98
|
20.55
|
24.05
|
30.25
|
|
kW
|
12.03
|
12.63
|
18.86
|
19.47
|
22.85
|
28.75
|
Cooling air requirement
|
m3/s
|
1.19
|
1.19
|
1.96
|
1.96
|
1.96
|
2.6
|
Sound pressure level LpA
(1 m) at 50/60 Hz
|
dB
|
75/77
|
75/77
|
77/79
|
77/79
|
77/79
|
77/79
|
Cable length, max.
|
|
|
|
|
|
|
|
|
m
|
300
|
300
|
300
|
300
|
300
|
300
|
|
m
|
450
|
450
|
450
|
450
|
450
|
450
|
Degree of protection
|
|
IP20
|
IP20
|
IP20
|
IP20
|
IP20
|
IP20
|
Dimensions
|
|
|
|
|
|
|
|
|
mm
|
1600
|
1600
|
2200
|
2200
|
2200
|
2800
|
|
mm
|
2000
|
2000
|
2000
|
2000
|
2000
|
2000
|
|
mm
|
600
|
600
|
600
|
600
|
600
|
600
|
Weight, approx.
|
kg
|
892
|
892
|
1716
|
1716
|
1716
|
2300
|
Frame size
|
|
G
|
G
|
H
|
H
|
H
|
J
|
Note: The power data in hp units are based on the NEC/CEC standards for the North American market.
Information about line supply connections, motor connections and cabinet grounding can be found under
Cable cross-sections and connections
.
1) Rated power of a typ. 6-pole standard induction motor based on IL or IH with 500 V or 690 V 3 AC 50 Hz.
2) Rated power of a typ. 6-pole standard induction motor based on IL or IH with 575 V 3 AC 60 Hz.
3) The base load current IL is the basis for a duty cycle of 110 % for 60 s or 150 % for 10 s with a duty cycle duration of 300 s.
4) The base load current IH is the basis for a duty cycle of 150 % for 60 s or 160 % for 10 s with a duty cycle duration of 300 s.
5) If the drive closed-loop control is still to remain active when the line supply fails, then the equipment must be provided with an external 24 V DC supply.
6)
Information regarding the correlation between the pulse frequency and max. output current/output frequency is provided in the SINAMICS Low Voltage Engineering Manual.
7) The specified power losses are the maximum values at 100 % utilization. The values are lower under normal operating conditions.
Line voltage 500 … 690 V 3 AC 50 Hz
|
SINAMICS S150 Converter Cabinet Units
|
|
|
6SL3710-7LG38-1AA3
|
6SL3710-7LG38-8AA3
|
6SL3710-7LG41-0AA3
|
6SL3710-7LG41-3AA3
|
Type rating
|
|
|
|
|
|
|
kW
|
800
|
900
|
1000
|
1200
|
|
kW
|
710
|
800
|
900
|
1000
|
|
kW
|
560
|
630
|
710
|
900
|
|
kW
|
500
|
560
|
630
|
800
|
|
hp
|
800
|
900
|
1000
|
1250
|
|
hp
|
700
|
800
|
900
|
1000
|
Output current
|
|
|
|
|
|
|
A
|
810
|
910
|
1025
|
1270
|
|
A
|
790
|
880
|
1000
|
1230
|
|
A
|
724
|
814
|
917
|
1136
|
|
A
|
1185
|
1320
|
1500
|
1845
|
Infeed/regenerative feedback current
|
|
|
|
|
|
|
A
|
732
|
821
|
923
|
1142
|
- Max. input current Imax E
|
A
|
1218
|
1367
|
1537
|
1905
|
Current demand, max. 5)
|
|
|
|
|
|
- 24 V DC auxiliary power supply
|
A
|
Internal
|
Internal
|
Internal
|
Internal
|
Pulse frequency 6
|
|
|
|
|
|
|
kHz
|
1.25
|
1.25
|
1.25
|
1.25
|
|
|
|
|
|
|
|
kHz
|
1.25
|
1.25
|
1.25
|
1.25
|
|
kHz
|
7.5
|
7.5
|
7.5
|
7.5
|
Power loss, max. 7)
|
|
|
|
|
|
|
kW
|
34.45
|
34.65
|
36.15
|
42.25
|
|
kW
|
32.75
|
32.85
|
34.25
|
39.25
|
Cooling air requirement
|
m3/s
|
2.6
|
2.6
|
2.6
|
2.6
|
Sound pressure level LpA
(1 m) at 50/60 Hz
|
dB
|
77/79
|
77/79
|
77/79
|
77/79
|
Cable length, max.
|
|
|
|
|
|
|
m
|
300
|
300
|
300
|
300
|
|
m
|
450
|
450
|
450
|
450
|
Degree of protection
|
|
IP20
|
IP20
|
IP20
|
IP20
|
Dimensions
|
|
|
|
|
|
|
mm
|
2800
|
2800
|
2800
|
2800
|
|
mm
|
2000
|
2000
|
2000
|
2000
|
|
mm
|
600
|
600
|
600
|
600
|
Weight, approx.
|
kg
|
2408
|
2408
|
2408
|
2408
|
Frame size
|
|
J
|
J
|
J
|
J
|
Note: The power data in hp units are based on the NEC/CEC standards for the North American market.
Information about line supply connections, motor connections and cabinet grounding can be found under
Cable cross-sections and connections
.
1) Rated power of a typ. 6-pole standard induction motor based on IL or IH with 500 V or 690 V 3 AC 50 Hz.
2) Rated power of a typ. 6-pole standard induction motor based on IL or IH with 575 V 3 AC 60 Hz.
3) The base load current IL is the basis for a duty cycle of 110 % for 60 s or 150 % for 10 s with a duty cycle duration of 300 s.
4) The base load current IH is the basis for a duty cycle of 150 % for 60 s or 160 % for 10 s with a duty cycle duration of 300 s.
5) If the drive closed-loop control is still to remain active when the line supply fails, then the equipment must be provided with an external 24 V DC supply.
6)
Information regarding the correlation between the pulse frequency and max. output current/output frequency is provided in the SINAMICS Low Voltage Engineering Manual.
7) The specified power losses are the maximum values at 100 % utilization. The values are lower under normal operating conditions.
|
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Àðìàòóðà DENDOR
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Äàò÷èêè è èçìåðèòåëè
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Ðåãóëÿòîðû è ðåãèñòðàòîðû
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Ïíåâìàòè÷åñêîå îáîðóäîâàíèå
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Êðàíû è Êëàïàíû
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Èçìåðèòåëüíûå ïðèáîðû
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Ñèñòåìû áåñïðîâîäíîãî óïðàâëåíèÿ «óìíûé äîì»
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Áåñêîíòàêòíûå âûêëþ÷àòåëè Êîíå÷íûå âûêëþ÷àòåëè Îïòè÷åñêèå äàò÷èêè Ýíêîäåðû
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
SKW-FS - Óñòàíîâêà óìÿã÷åíèÿ
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
SKW-FK - Óñòàíîâêà îáåçæåëåçèâàíèÿ
|