Siemens
СРЕДСТВА ПРОМЫШЛЕННОЙ АВТОМАТИЗАЦИИ
официальный партнер Сименс
Каталог СА01 2015
архивный
(4872) 700-366
skenergo@mail.ru

?

Order?No.

6GK5?744-1AA60-2AA0

6GK5?746-1AA60-4AA0

6GK5?747-1AA60-6AA0

 

6GK5?744-1AA60-2AB0 1)

6GK5?746-1AA60-4AB0 1)

6GK5?747-1AA60-6AB0 1)

Product-type?designation

SCALANCE?W744-1PRO

SCALANCE?W746-1PRO

SCALANCE?W747-1RR

Transmission?rate

 

 

 

Transmission?rate

 

 

 

  • with?W-LAN?maximum

54 Mbit/s

54 Mbit/s

54 Mbit/s

  • with?Industrial?Ethernet

10 … 100 Mbit/s

10 … 100 Mbit/s

10 … 100 Mbit/s

  • note

Due?to?the?simultaneous?use?of?several?radio?channels,?a?transmission?rate?of?108?Mbit/s?is?possible?(turbo?mode)

Due?to?the?simultaneous?use?of?several?radio?channels,?a?transmission?rate?of?108?Mbit/s?is?possible?(turbo?mode)

Due?to?the?simultaneous?use?of?several?radio?channels,?a?transmission?rate?of?108?Mbit/s?is?possible?(turbo?mode)

Interfaces

 

 

 

Number?of?electrical?connections

 

 

 

  • for?network?components?and?terminal?equipment

1

1

1

  • for?power?supply

1

1

1

  • for?redundant?power?supply

1

1

1

Design?of?electrical?connection

 

 

 

  • for?network?components?and?terminal?equipment

Hybrid?socket,?RJ45?integrated

Hybrid?socket,?RJ45?integrated

Hybrid?socket,?RJ45?integrated

  • for?power?supply

M12?interface?(4-pole,?A-coded),?hybrid?socket,?PoE

M12?interface?(4-pole,?A-coded),?hybrid?socket,?PoE

M12?interface?(4-pole,?A-coded),?hybrid?socket,?PoE

design?of?the?removable?storage?C-PLUG

Yes

Yes

Yes

Interfaces?wireless

 

 

 

Number?of?radio?cards?permanently?installed

1

1

1

Number?of?electrical?connections?for?external?antenna(s)

2

2

2

Design?of?the?electrical?connection?for?external?antenna(s)

R-SMA?female?(socket)

R-SMA?female?(socket)

R-SMA?female?(socket)

Product?property?external?antenna?can?be?mounted?directly?on?device

Yes

Yes

Yes

Supply?voltage,?current?consumption,?power?loss

 

 

 

Type?of?voltage?of?supply?voltage

DC

DC

DC

Supply?voltage

 

 

 

  • 1?from?M12?Power?Connector?(A-coded)?for?redundant?power?supply

24 V

24 V

24 V

  • 2?from?M12?Power?Connector?(A-coded)?for?redundant?power?supply

48 V

48 V

48 V

  • 1?from?IE?Hybrid?Cable?2x2?+?4x0.34

24 V

24 V

24 V

  • 2?from?IE?Hybrid?Cable?2x2?+?4x0.34

48 V

48 V

48 V

  • from?Power-over-Ethernet?according?IEEE802.3at?for?type?1?and?IEEE802.3af

48 V

48 V

48 V

Current?consumed

 

 

 

  • at?24?V?with?DC?typical

0.25 A

0.25 A

0.25 A

  • at?48?V?with?DC?typical

0.13 A

0.13 A

0.13 A

  • with?Power-over-Ethernet?according?to?IEEE802.3at?for?type?1?and?IEEE802.3af?typical

0.13 A

0.13 A

0.13 A

Effective?power?loss

 

 

 

  • at?24V?for?DC?typical

7 W

7 W

7 W

  • at?48?V?with?DC?typical

7 W

7 W

7 W

  • with?Power-over-Ethernet?according?to?IEEE802.3at?for?type?1?and?IEEE802.3af?typical

7 W

7 W

7 W

Permitted?ambient?conditions

 

 

 

Ambient?temperature

 

 

 

  • during?operating

-20 … +60 °C

-20 … +60 °C

-20 … +60 °C

  • during?storage

-40 … +70 °C

-40 … +70 °C

-40 … +70 °C

  • during?transport

-40 … +70 °C

-40 … +70 °C

-40 … +70 °C

Relative?humidity?at?25?°C?without?condensation?during?operating?maximum

100 %

100 %

100 %

Protection?class?IP

IP65

IP65

IP65

Ambient?condition?for?(standard)?operation?mode

When?used?under?hazardous?conditions?(Zone?2),?the?SCALANCE?W788-xPRO/RR?or?W74x-1PRO/RR?product?must?be?installed?in?an?enclosure.?To?comply?with?EN?50021,?this?enclosure?must?meet?the?requirements?of?at?least?IP?54?in?compliance?with?EN?60529.

When?used?under?hazardous?conditions?(Zone?2),?the?SCALANCE?W788-xPRO/RR?or?W74x-1PRO/RR?product?must?be?installed?in?an?enclosure.?To?comply?with?EN?50021,?this?enclosure?must?meet?the?requirements?of?at?least?IP?54?in?compliance?with?EN?60529.

When?used?under?hazardous?conditions?(Zone?2),?the?SCALANCE?W788-xPRO/RR?or?W74x-1PRO/RR?product?must?be?installed?in?an?enclosure.?To?comply?with?EN?50021,?this?enclosure?must?meet?the?requirements?of?at?least?IP?54?in?compliance?with?EN?60529.

Design,?dimensions?and?weight

 

 

 

Width?of?enclosure?without?antenna

125 mm

125 mm

125 mm

Height?of?enclosure?without?antenna

88 mm

88 mm

88 mm

Depth?of?enclosure?without?antenna

108 mm

108 mm

108 mm

Net?weight

1,05 kg

1.05 kg

1.05 kg

Type?of?mounting

 

 

 

  • S7-300?rail?mounting

Yes

Yes

Yes

  • wall?mounting

Yes

Yes

Yes

Wireless?frequencies

 

 

 

Radio?frequency

 

 

 

  • for?WLAN?in?2.4?GHz?frequency?band

2,41 … 2,48 GHz

2,41 … 2,48 GHz

2,41 … 2,48 GHz

  • for?WLAN?in?5?GHz?frequency?band

4,9 … 5,8 GHz

4,9 … 5,8 GHz

4,9 … 5,8 GHz

Product?properties,?functions,?components?general

 

 

 

Product?function

 

 

 

  • Access?Point?Mode

No

No

No

  • Client?Mode

Yes

Yes

Yes

Number?of?SSIDs

1

1

1

Product?function

 

 

 

  • Dual?Client

No

No

Yes

  • iHOP

No

No

Yes

  • iPCF?Access?Point

-

-

-

  • iPCF

No

No

Yes

  • iPCF-MC?Access?Point

-

-

-

  • iPCF-MC

No

No

Yes

Number?of?iPCF-capable?radio?modules

0

0

1

Product?functions?management,?configuration

 

 

 

Number?of?manageable?IP?addresses?in?client

1

8

8

Product?function

 

 

 

  • CLI

Yes

Yes

Yes

  • web-based?management

Yes

Yes

Yes

  • MIB?support

Yes

Yes

Yes

  • TRAPs?via?email

Yes

Yes

Yes

  • Configuration?with?STEP?7

No

Yes

Yes

  • configuration?with?STEP?7?in?the?TIA?Portal

No

Yes

Yes

  • operation?with?IWLAN?controller

No

No

No

  • operation?with?Enterasys?WLAN?controller

No

No

No

  • iQoS

No

No

No

  • forced?roaming?with?IWLAN

No

No

No

  • WDS

No

No

No

Protocol?is?supported

 

 

 

  • Address?Resolution?Protocol?(ARP)

Yes

Yes

Yes

  • ICMP

Yes

Yes

Yes

  • Telnet

Yes

Yes

Yes

  • HTTP

Yes

Yes

Yes

  • HTTPS

Yes

Yes

Yes

  • TFTP

Yes

Yes

Yes

  • SNMP?v1

Yes

Yes

Yes

  • SNMP?v2

Yes

Yes

Yes

  • SNMP?v3

Yes

Yes

Yes

  • DCP

Yes

Yes

Yes

  • LLDP

No

Yes

Yes

Identification?&?maintenance

 

 

 

  • I&M0?-?device-specific?information

Yes

Yes

Yes

  • I&M1?-?plant?identification/location?name

Yes

Yes

Yes

Product?functions?Diagnosis

 

 

 

Product?function

 

 

 

  • PROFINET?IO?diagnosis

No

Yes

Yes

  • Link?Check

No

No

No

  • connection?monitoring?IP-Alive

No

No

No

  • localization?via?Aeroscout

No

No

No

  • SysLog

Yes

Yes

Yes

Product?functions?VLAN

 

 

 

Product?function?function?VLAN?with?IWLAN

No

No

No

Product?functions?DHCP

 

 

 

Product?function

 

 

 

  • DHCP?client

Yes

Yes

Yes

  • in?Client?Mode?DHCP?server?via?LAN

No

Yes

Yes

Product?functions?Redundancy

 

 

 

Protocol?is?supported?STP/RSTP

-

-

-

Product?functions?Security

 

 

 

Product?function

 

 

 

  • ACL?-?MAC-based

No

No

No

  • Management?security,?ACL-IP?based

No

No

No

  • IEEE?802.1x?(radius)

Yes

Yes

Yes

  • NAT/NAPT

No

Yes

Yes

  • access?protection?according?to?IEEE802.11i

Yes

Yes

Yes

  • WPA/WPA2

Yes

Yes

Yes

  • TKIP/AES

Yes

Yes

Yes

Protocol?is?supported?SSH

Yes

Yes

Yes

Product?functions?Time

 

 

 

Protocol?is?supported

 

 

 

  • SNTP

Yes

Yes

Yes

  • SIMATIC?Time

No

No

No

Standards,?specifications,?approvals

 

 

 

Standard

 

 

 

  • for?EMC?from?FM

FM 3611:?Class?I,?Division?2,?Groups?A,B,C,D,?T4?/?Class?1,?Zone?2,?Group?IIC,?T4

FM 3611:?Class?I,?Division?2,?Groups?A,B,C,D,?T4?/?Class?1,?Zone?2,?Group?IIC,?T4

FM 3611:?Class?I,?Division?2,?Groups?A,B,C,D,?T4?/?Class?1,?Zone?2,?Group?IIC,?T4

  • for?hazardous?zone

EN?60079-15:2005,?EN?60079-0:2006,?II?3?G?Ex?nA?II?T4?KEMA?07?ATEX?0145X

EN?60079-15:2005,?EN?60079-0:2006,?II?3?G?Ex?nA?II?T4?KEMA?07?ATEX?0145X

EN?60079-15:2005,?EN?60079-0:2006,?II?3?G?Ex?nA?II?T4?KEMA?07?ATEX?0145X

  • for?safety?of?CSA?and?UL

UL?60950-1?CSA?C22.2?No.?60950-1

UL?60950-1?CSA?C22.2?No.?60950-1

UL?60950-1?CSA?C22.2?No.?60950-1

  • for?hazardous?area?of?CSA?and?UL

ISA?12.12.01-2000,?CSA?C22.2?No.?213-M1987,?CL.?1,?Div.?2,?GP.??A,B,C,D,?T4?/?CL.?1,?Zone?2,?GP?IIC,?T4?/?CL.?1,?Zone?2,?AEx?nC?IIC,?T4

ISA?12.12.01-2000,?CSA?C22.2?No.?213-M1987,?CL.?1,?Div.?2,?GP.??A,B,C,D,?T4?/?CL.?1,?Zone?2,?GP?IIC,?T4?/?CL.?1,?Zone?2,?AEx?nC?IIC,?T4

ISA?12.12.01-2000,?CSA?C22.2?No.?213-M1987,?CL.?1,?Div.?2,?GP.??A,B,C,D,?T4?/?CL.?1,?Zone?2,?GP?IIC,?T4?/?CL.?1,?Zone?2,?AEx?nC?IIC,?T4

Verification?of?suitability

 

 

 

  • CE?mark

Yes

Yes

Yes

  • EC?declaration?of?conformity

Yes

Yes

Yes

  • C-Tick

Yes

Yes

Yes

  • CCC

No

No

No

  • Railway?application?in?accordance?with?EN?50155

Yes

Yes

Yes

  • e1?approval

Yes

Yes

Yes

  • E1?approval

Yes

Yes

Yes

  • Power-over-Ethernet?according?IEEE802.3at?for?type?1?and?IEEE802.3af

Yes

Yes

Yes

Standard?for?wireless?communication

 

 

 

  • IEEE?802.11a

Yes

Yes

Yes

  • IEEE?802.11b

Yes

Yes

Yes

  • IEEE?802.11e

Yes

Yes

Yes

  • IEEE?802.11g

Yes

Yes

Yes

  • IEEE?802.11h

Yes

Yes

Yes

  • IEEE?802.11i

Yes

Yes

Yes

  • IEEE?802.11n

No

No

No

Wireless?approval

You?will?find?the?current?list?of?countries?at:?www.siemens.de/funkzulassungen

You?will?find?the?current?list?of?countries?at:?www.siemens.de/funkzulassungen

You?will?find?the?current?list?of?countries?at:?www.siemens.de/funkzulassungen

Marine?classification?association

 

 

 

  • American?Bureau?of?Shipping?Europe?Ltd.?(ABS)

Yes

No

No

  • Bureau?Veritas?(BV)

Yes

No

No

  • Det?Norske?Veritas?(DNV)

No

No

No

  • Germanische?Lloyd?(GL)

Yes

No

No

  • Lloyds?Register?of?Shipping?(LRS)

Yes

No

No

  • Nippon?Kaiji?Kyokai?(NK)

Yes

No

No

  • Polski?Rejestr?Statkow?(PRS)

Yes

No

No

Accessories

 

 

 

Accessories

2?antennas,?hybrid?connector?included?in?scope?of?delivery

2?antennas,?hybrid?connector?included?in?scope?of?delivery

2?antennas,?hybrid?connector?included?in?scope?of?delivery


1)  Wireless?approval?in?the?USA

Order?No.

6GK5?744-1AA30-2AA0

6GK5?746-1AA30-4AA0

6GK5?747-1AA30-6AA0

 

6GK5?744-1AA30-2AB0 1)

6GK5?746-1AA30-4AB0 1)

6GK5?747-1AA30-6AB0 1)

Product-type?designation

SCALANCE?W744-1

SCALANCE?W746-1

SCALANCE?W747-1

Transmission?rate

 

 

 

Transmission?rate

 

 

 

  • with?W-LAN?maximum

54 Mbit/s

54 Mbit/s

54 Mbit/s

  • with?Industrial?Ethernet

10 … 100 Mbit/s

10 … 100 Mbit/s

10 … 100 Mbit/s

  • note

Due?to?the?simultaneous?use?of?several?radio?channels,?a?transmission?rate?of?108?Mbit/s?is?possible?(turbo?mode)

Due?to?the?simultaneous?use?of?several?radio?channels,?a?transmission?rate?of?108?Mbit/s?is?possible?(turbo?mode)

Due?to?the?simultaneous?use?of?several?radio?channels,?a?transmission?rate?of?108?Mbit/s?is?possible?(turbo?mode)

Interfaces

 

 

 

Number?of?electrical?connections

 

 

 

  • for?network?components?and?terminal?equipment

1

1

1

  • for?power?supply

1

1

1

  • for?redundant?power?supply

1

1

1

Design?of?electrical?connection

 

 

 

  • for?network?components?and?terminal?equipment

RJ45?socket

RJ45?socket

RJ45?socket

  • for?power?supply

4-pole?screw?terminal,?PoE

4-pole?screw?terminal,?PoE

4-pole?screw?terminal,?PoE

design?of?the?removable?storage?C-PLUG

Yes

Yes

Yes

Interfaces?wireless

 

 

 

Number?of?radio?cards?permanently?installed

1

1

1

Number?of?electrical?connections?for?external?antenna(s)

2

2

2

Design?of?the?electrical?connection?for?external?antenna(s)

R-SMA?female?(socket)

R-SMA?female?(socket)

R-SMA?female?(socket)

Product?property?external?antenna?can?be?mounted?directly?on?device

Yes

Yes

Yes

Supply?voltage,?current?consumption,?power?loss

 

 

 

Type?of?voltage?of?supply?voltage

DC

DC

DC

Supply?voltage

 

 

 

  • 1?from?terminal?block

24 V

24 V

24 V

  • 2?from?terminal?block

48 V

48 V

48 V

  • from?Power-over-Ethernet?according?IEEE802.3at?for?type?1?and?IEEE802.3af

48 V

48 V

48 V

Current?consumed

 

 

 

  • at?24?V?with?DC?typical

0.23 A

0.23 A

0.23 A

  • at?48?V?with?DC?typical

0.12 A

0.12 A

0.12 A

  • with?Power-over-Ethernet?according?to?IEEE802.3at?for?type?1?and?IEEE802.3af?typical

0.12 A

0.12 A

0.12 A

Effective?power?loss

 

 

 

  • at?24V?for?DC?typical

6 W

6 W

6 W

  • at?48?V?with?DC?typical

6 W

6 W

6 W

  • with?Power-over-Ethernet?according?to?IEEE802.3at?for?type?1?and?IEEE802.3af?typical

6 W

6 W

6 W

Permitted?ambient?conditions

 

 

 

Ambient?temperature

 

 

 

  • during?operating

-20 … +60 °C

-20 … +60 °C

-20 … +60 °C

  • during?storage

-40 … +70 °C

-40 … +70 °C

-40 … +70 °C

  • during?transport

-40 … +70 °C

-40 … +70 °C

-40 … +70 °C

Relative?humidity?at?25?°C?without?condensation?during?operating?maximum

90 %

90 %

90 %

Protection?class?IP

IP30

IP30

IP30

Ambient?condition?for?(standard)?operation?mode

-

-

-

Design,?dimensions?and?weight

 

 

 

Width?of?enclosure?without?antenna

100 mm

100 mm

100 mm

Height?of?enclosure?without?antenna

205 mm

205 mm

205 mm

Depth?of?enclosure?without?antenna

20 mm

20 mm

20 mm

Net?weight

0.29 kg

0.29 kg

0.29 kg

Type?of?mounting

 

 

 

  • S7-300?rail?mounting

-

-

-

  • wall?mounting

Yes

Yes

Yes

Type?of?mounting

For?mounting?on?35?mm?DIN?and?S7-300?mounting?rail,?an?additional?adapter?plate?is?required

For?mounting?on?35?mm?DIN?and?S7-300?mounting?rail,?an?additional?adapter?plate?is?required

For?mounting?on?35?mm?DIN?and?S7-300?mounting?rail,?an?additional?adapter?plate?is?required

Wireless?frequencies

 

 

 

Radio?frequency

 

 

 

  • for?WLAN?in?2.4?GHz?frequency?band

2,41 … 2,48 GHz

2,41 … 2,48 GHz

2,41 … 2,48 GHz

  • for?WLAN?in?5?GHz?frequency?band

4,9 … 5,8 GHz

4,9 … 5,8 GHz

4,9 … 5,8 GHz

Product?properties,?functions,?components?general

 

 

 

Product?function

 

 

 

  • Access?Point?Mode

No

No

No

  • Client?Mode

Yes

Yes

Yes

Number?of?SSIDs

1

1

1

Product?function

 

 

 

  • Dual?Client

No

No

Yes

  • iHOP

No

No

Yes

  • iPCF?Access?Point

-

-

-

  • iPCF

No

No

Yes

  • iPCF-MC?Access?Point

-

-

-

  • iPCF-MC

No

No

Yes

Number?of?iPCF-capable?radio?modules

0

0

1

Product?functions?management,?configuration

 

 

 

Number?of?manageable?IP?addresses?in?client

1

8

8

Product?function

 

 

 

  • CLI

Yes

Yes

Yes

  • web-based?management

Yes

Yes

Yes

  • MIB?support

Yes

Yes

Yes

  • TRAPs?via?email

Yes

Yes

Yes

  • Configuration?with?STEP?7

No

Yes

Yes

  • configuration?with?STEP?7?in?the?TIA?Portal

No

Yes

Yes

  • operation?with?IWLAN?controller

No

No

No

  • operation?with?Enterasys?WLAN?controller

No

No

No

  • iQoS

No

No

No

  • forced?roaming?with?IWLAN

No

No

No

  • WDS

No

No

No

Protocol?is?supported

 

 

 

  • Address?Resolution?Protocol?(ARP)

Yes

Yes

Yes

  • ICMP

Yes

Yes

Yes

  • Telnet

Yes

Yes

Yes

  • HTTP

Yes

Yes

Yes

  • HTTPS

Yes

Yes

Yes

  • TFTP

Yes

Yes

Yes

  • SNMP?v1

Yes

Yes

Yes

  • SNMP?v2

Yes

Yes

Yes

  • SNMP?v3

Yes

Yes

Yes

  • DCP

Yes

Yes

Yes

  • LLDP

No

Yes

Yes

Identification?&?maintenance

 

 

 

  • I&M0?-?device-specific?information

Yes

Yes

Yes

  • I&M1?-?plant?identification/location?name

Yes

Yes

Yes

Product?functions?Diagnosis

 

 

 

Product?function

 

 

 

  • PROFINET?IO?diagnosis

No

Yes

Yes

  • Link?Check

No

No

No

  • connection?monitoring?IP-Alive

No

No

No

  • localization?via?Aeroscout

No

No

No

  • SysLog

Yes

Yes

Yes

Product?functions?VLAN

 

 

 

Product?function?function?VLAN?with?IWLAN

No

No

No

Product?functions?DHCP

 

 

 

Product?function

 

 

 

  • DHCP?client

Yes

Yes

Yes

  • in?Client?Mode?DHCP?server?via?LAN

No

Yes

Yes

Product?functions?Redundancy

 

 

 

Protocol?is?supported?STP/RSTP

-

-

-

Product?functions?Security

 

 

 

Product?function

 

 

 

  • ACL?-?MAC-based

No

No

No

  • Management?security,?ACL-IP?based

No

No

No

  • IEEE?802.1x?(radius)

Yes

Yes

Yes

  • NAT/NAPT

No

Yes

Yes

  • access?protection?according?to?IEEE802.11i

Yes

Yes

Yes

  • WPA/WPA2

Yes

Yes

Yes

  • TKIP/AES

Yes

Yes

Yes

Protocol?is?supported?SSH

Yes

Yes

Yes

Product?functions?Time

 

 

 

Protocol?is?supported

 

 

 

  • SNTP

Yes

Yes

Yes

  • SIMATIC?Time

No

No

No

Standards,?specifications,?approvals

 

 

 

Standard

 

 

 

  • for?EMC?from?FM

FM 3611:?Class?I,?Division?2,?Groups?A,B,C,D,?T4?/?Class?1,?Zone?2,?Group?IIC,?T4

FM 3611:?Class?I,?Division?2,?Groups?A,B,C,D,?T4?/?Class?1,?Zone?2,?Group?IIC,?T4

FM 3611:?Class?I,?Division?2,?Groups?A,B,C,D,?T4?/?Class?1,?Zone?2,?Group?IIC,?T4

  • for?hazardous?zone

EN?60079-15:2005,?EN?60079-0:2006,?II?3?G?Ex?nA?II?T4?KEMA?07?ATEX?0145X?(only?approved?in?combination?with?an?enclosure?with?degree?of?protection?of?at?least?IP?54)

EN?60079-15:2005,?EN?60079-0:2006,?II?3?G?Ex?nA?II?T4?KEMA?07?ATEX?0145X?(only?approved?in?combination?with?an?enclosure?with?degree?of?protection?of?at?least?IP?54)

EN?60079-15:2005,?EN?60079-0:2006,?II?3?G?Ex?nA?II?T4?KEMA?07?ATEX?0145X?(only?approved?in?combination?with?an?enclosure?with?degree?of?protection?of?at?least?IP?54)

  • for?safety?of?CSA?and?UL

UL?60950-1?CSA?C22.2?No.?60950-1

UL?60950-1?CSA?C22.2?No.?60950-1

UL?60950-1?CSA?C22.2?No.?60950-1

  • for?hazardous?area?of?CSA?and?UL

ISA?12.12.01-2000,?CSA?C22.2?No.?213-M1987,?CL.?1,?Div.?2,?GP.??A,B,C,D,?T4?/?CL.?1,?Zone?2,?GP?IIC,?T4?/?CL.?1,?Zone?2,?AEx?nC?IIC,?T4?(only?approved?in?combination?with?an?enclosure?with?degree?of?protection?of?at?least?IP?54)

ISA?12.12.01-2000,?CSA?C22.2?No.?213-M1987,?CL.?1,?Div.?2,?GP.??A,B,C,D,?T4?/?CL.?1,?Zone?2,?GP?IIC,?T4?/?CL.?1,?Zone?2,?AEx?nC?IIC,?T4?(only?approved?in?combination?with?an?enclosure?with?degree?of?protection?of?at?least?IP?54)

ISA?12.12.01-2000,?CSA?C22.2?No.?213-M1987,?CL.?1,?Div.?2,?GP.??A,B,C,D,?T4?/?CL.?1,?Zone?2,?GP?IIC,?T4?/?CL.?1,?Zone?2,?AEx?nC?IIC,?T4?(only?approved?in?combination?with?an?enclosure?with?degree?of?protection?of?at?least?IP?54)

Verification?of?suitability

 

 

 

  • CE?mark

Yes

Yes

Yes

  • EC?declaration?of?conformity

Yes

Yes

Yes

  • C-Tick

Yes

Yes

Yes

  • CCC

No

No

No

  • Railway?application?in?accordance?with?EN?50155

Yes

Yes

Yes

  • e1?approval

Yes

Yes

Yes

  • E1?approval

Yes

Yes

Yes

  • Power-over-Ethernet?according?IEEE802.3at?for?type?1?and?IEEE802.3af

Yes

Yes

Yes

Standard?for?wireless?communication

 

 

 

  • IEEE?802.11a

Yes

Yes

Yes

  • IEEE?802.11b

Yes

Yes

Yes

  • IEEE?802.11e

Yes

Yes

Yes

  • IEEE?802.11g

Yes

Yes

Yes

  • IEEE?802.11h

Yes

Yes

Yes

  • IEEE?802.11i

Yes

Yes

Yes

  • IEEE?802.11n

No

No

No

Wireless?approval

You?will?find?the?current?list?of?countries?at:?www.siemens.de/funkzulassungen

You?will?find?the?current?list?of?countries?at:?www.siemens.de/funkzulassungen

You?will?find?the?current?list?of?countries?at:?www.siemens.de/funkzulassungen

Marine?classification?association

 

 

 

  • American?Bureau?of?Shipping?Europe?Ltd.?(ABS)

Yes

No

No

  • Bureau?Veritas?(BV)

Yes

No

No

  • Det?Norske?Veritas?(DNV)

No

No

No

  • Germanische?Lloyd?(GL)

Yes

No

No

  • Lloyds?Register?of?Shipping?(LRS)

Yes

No

No

  • Nippon?Kaiji?Kyokai?(NK)

Yes

No

No

  • Polski?Rejestr?Statkow?(PRS)

Yes

No

No

Accessories

 

 

 

Accessories

24?V?DC?screw?terminal?included?in?scope?of?delivery

24?V?DC?screw?terminal?included?in?scope?of?delivery

24?V?DC?screw?terminal?included?in?scope?of?delivery


1)  Wireless?approval?in?the?USA

















skener.ru

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Арматура DENDOR

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Датчики и измерители

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Регуляторы и регистраторы

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Пневматическое оборудование

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Краны и Клапаны

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Измерительные приборы

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Системы беспроводного управления «умный дом»

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Бесконтактные выключатели Конечные выключатели Оптические датчики Энкодеры

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
SKW-FS - Установка умягчения

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
SKW-FK - Установка обезжелезивания
Каталог оборудования 2015
Каталог продуктов Siemens Industry Приводная техника Техника автоматизации Системы автоматизации Системы визуализации SIMATIC HMI Системы идентификации Промышленные коммуникации SIMATIC NET Введение Industrial Ethernet PROFINET Введение Привода Контроллеры Система управления процессами SIMATIC PCS 7 Распределенная периферия Система управления перемещениями SIMOTION Системы ЧПУ SINUMERIK Устройства отображения и контроля Активные сетевые компоненты Промышленные ПК Коммутационные и защитные приборы для распределения энергии Обзор системы Измерительные приборы SENTRON Конфигурирование, визуализация и управление с SIMATIC Конфигурирование, визуализация и управление с SENTRON Производственные датчики Пассивные сетевые компоненты Сетевые компоненты для Industrial Ethernet Industrial Ethernet коммутаторы Безопасность передачи данных в промышленных сетях Industrial Wireless LAN Industrial Wireless Communication Промышленная мобильная коммуникация Access Points IEEE 802.11n SCALANCE W-780 Access Points SCALANCE W-740 Client Modules Беспрводные устройства Коаксиальный кабель RCoax Аксессуары Маршрутизаторы Аппаратура управления Блоки питания SITOP Датчики Инжиниринговые пакеты Engineering / Network management / Diagnostics Технологические компоненты PROFINET Системный интерфейс к SIMATIC HMI PROFIBUS AS-интерфейс IO-Link Промышленная беспроводная связь SINAUT ST7 Информационная безопасность в промышленности Сетевые переходы ECOFAST Промышленные аппараты управления SIRIUS Промышленные информационные технологии Управление на базе РС Системы управления процессом Датчики Блоки питания Продукты для специальных требований Автоматизация и безопасность зданий Низковольтная коммутационная техника Технология безопасности Системные решения и продукты для отраслей Сервис ... и все, что Вам еще необходимо

  © ООО "СК ЭНЕРГО" 2007-2022
  (4872) 700-366  skenergo@mail.ru
Яндекс.Метрика