Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/new/cat.php on line 184
Order No. |
6GK5 552-0AA00-2AR2 |
6GK5 528-0AA00-2AR2 |
6GK5 552-0AA00-2HR2 |
6GK5 528-0AA00-2HR2 |
|
Product type designation |
SCALANCE XR552-12M |
|
Transmission rate |
||
Transfer rate 1 |
10 Mbit/s |
10 Mbit/s |
Transfer rate 2 |
100 Mbit/s |
100 Mbit/s |
Transfer rate 3 |
1 000 Mbit/s |
1 000 Mbit/s |
Transfer rate 4 |
10 Gbit/s |
10 Gbit/s |
Interfaces |
||
Number of electrical/optical connections for network components or terminal equipment maximum |
52 |
28 |
Number of electrical connections |
||
|
4 |
4 |
|
1 |
1 |
|
1 |
1 |
|
1 |
1 |
|
12 |
6 |
|
1 |
1 |
|
1 |
1 |
Design of electrical connection |
||
|
Dependent on selected media modules |
Dependent on selected media modules |
|
- |
- |
|
RJ11 port |
RJ11 port |
|
RJ45 port |
RJ45 port |
|
2-pole terminal block |
2-pole terminal block |
|
4-pole terminal block |
4-pole terminal block |
design of the optical connection for fibre optic cable |
||
|
Dependent on selected media modules |
Dependent on selected media modules |
|
Dependent on selected media modules |
Dependent on selected media modules |
|
||
Range at the optical interface depending on the optical fiber used |
- - |
- - |
design of the removable storage C-PLUG/KEY-PLUG |
Yes |
Yes |
Inputs/outputs |
||
Operating voltage of signaling contacts at AC rated value |
- |
- |
Operating current of signaling contacts at AC maximum |
- |
- |
Operating voltage of signaling contacts at DC rated value |
24 V |
24 V |
Operating current of signaling contacts at DC maximum |
0.1 A |
0.1 A |
Supply voltage, current consumption, power loss |
||
Type of voltage of supply voltage |
DC |
DC |
Supply voltage external |
24 V |
24 V |
|
19.2 V |
19.2 V |
|
28.8 V |
28.8 V |
Product component fusing at power supply input |
Yes |
Yes |
Type of fusing at input for supply voltage |
||
Consumed current maximum |
- |
- |
Active power loss at 24 V for DC |
- |
- |
Permitted ambient conditions |
||
Ambient temperature |
||
|
0 … 60 °C |
0 … 60 °C |
|
-40 ... +70 °C |
-40 ... +70 °C |
|
-40 ... +70 °C |
-40 ... +70 °C |
Relative humidity at 25 °C without condensation during operating maximum |
95 % |
95 % |
Protection class IP |
IP20 |
IP20 |
Design, dimensions and weight |
||
Design |
19" rack |
19" rack |
Width |
449 mm |
449 mm |
Height |
130.8 mm |
87.2 mm |
Depth |
305 mm |
305 mm |
Net weight |
10 kg |
10 kg |
Type of mounting Installation 19 inch |
Yes |
Yes |
Type of cable outlet |
Cable outlet at front |
Cable outlet at front |
Product properties, functions, componentsgeneral |
||
Cascading in the case of a redundant ring at reconfiguration time of <'~0.3'~s |
50 |
50 |
Cascading in cases of star structuring |
Any (depending only on signal propagation time) |
Any (depending only on signal propagation time) |
Product functionsmanagement, configuration |
||
Product function |
||
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
Protocol is supported |
||
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
Identification & maintenance |
||
|
Yes |
Yes |
|
Yes |
Yes |
Product functionsDiagnosis |
||
Product function |
||
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
Product functionsVLAN |
||
Product function |
||
|
Yes |
Yes |
|
- |
- |
|
- |
- |
|
Yes |
Yes |
Number of VLANs maximum |
255 |
255 |
Number of VLANs - dynamic maximum |
- |
- |
Protocol is supported GVRP |
Yes |
Yes |
Product functionsDHCP |
||
Product function |
||
|
Yes |
Yes |
|
No |
No |
|
Yes |
Yes |
|
Yes |
Yes |
Product functionsRouting |
||
Service Routing Note |
||
Product function |
||
|
- |
- |
|
- |
- |
|
- |
- |
|
- |
- |
Protocol is supported |
||
|
- |
- |
|
- |
- |
|
- |
- |
|
- |
- |
|
- |
- |
|
- |
- |
Product functionsRedundancy |
||
Product function |
||
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
Protocol is supported |
||
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
Product functionsSecurity |
||
Product function |
||
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
Protocol is supported SSH |
Yes |
Yes |
Product functionsTime |
||
Product function SICLOCK support |
Yes |
Yes |
Protocol is supported |
||
|
Yes |
Yes |
|
Yes |
Yes |
|
- |
- |
|
- |
- |
|
- |
- |
Type of time synchronization |
IEEE 1588 available soon |
IEEE 1588 available soon |
Standards, specifications, approvals |
||
Standard |
||
|
- |
- |
|
- |
- |
|
UL 60950-1, CSA C22.2 No. 60950-1 |
UL 60950-1, CSA C22.2 No. 60950-1 |
|
- |
- |
|
EN 61000-6-4 (Class A) |
EN 61000-6-4 (Class A) |
|
EN 61000-6-2 |
EN 61000-6-2 |
Verification of suitability |
EN 61000-6-2, EN 61000-6-4 |
EN 61000-6-2, EN 61000-6-4 |
|
Yes |
Yes |
|
Yes |
Yes |
Marine classification association |
||
|
- |
- |
|
- |
- |
|
- |
- |
|
- |
- |
|
- |
- |
|
- |
- |