Siemens
СРЕДСТВА ПРОМЫШЛЕННОЙ АВТОМАТИЗАЦИИ
официальный партнер Сименс
Каталог СА01 2012
архивный
(4872) 700-366
skenergo@mail.ru
1PH8 for SINAMICS S120 Combi for machine tools

1PH8 motor

Cooling

Forced ventilation

Ambient temperature, admissible

-15 ... +40 °C

Temperature monitoring

KTY84 temperature sensor in stator winding

Insulation of the stator winding in accordance with EN 60034-1 (IEC 60034-1)

For an ambient temperature of up to 40 °C

  • 1PH808/1PH810/1PH813

Temperature class 155 (F)

Motor fan ratings

  • 1PH808

230 V ± 10 %, 50 Hz
265 V ± 10 %, 60 Hz

  • 1PH810/1PH813

400 V 3 AC ± 10 %, 50 Hz
480 V 3 AC ± 10 %, 60 Hz

Encoder system, built-in

DRIVE-CLiQ interface

  • 1PH8...-1D...

22 bit incremental encoder (resolution 4194304, internal 2048 S/R) + commutation position 11 bit (encoder IC22DQ)1)

  • 1PH8...-1U...

20 bit incremental encoder (resolution 1048576, internal 512 S/R) without commutation position (encoder IN20DQ)2)

Sound pressure level L pA (1 m)
in accordance with EN ISO 1680
Tolerance + 3 dB

Rated pulse frequency 4 kHz

  • 1PH808/1PH810

70 dB

  • 1PH813

72 dB

Connection

  • 1PH808/1PH810/1PH813

Terminal box

  • Fan

  • 1PH808

Power connector

  • 1PH810/1PH813

Terminals in terminal box

  • Encoder system

Connector for signals (without mating connector) or DRIVE-CLiQ

Vibration magnitude

In accordance with Siemens/EN 60034-14 (IEC 60034-14)

Shaft and flange accuracy3)

In accordance with Siemens/DIN 42955 (IEC 60072-1)

Degree of protection in accordance with
EN 60034-5 (IEC 60034-5)

  • 1PH808/1PH810/1PH813

IP55

  • Fan

IP55

Rating plate

1 unit attached to motor
1 unit supplied loose in terminal box

Paint finish

Anthracite RAL 7016

Approvals, according to

cURus


1) Maximum speednmax = 12000 rpm.

2) Maximum speednmax = 15000 rpm.

3) Shaft extension run-out, concentricity of centering ring and shaft, and perpendicularity of flange to shaft.

Terminal box assignment, max. connectable conductor cross-sections

1PH8 motor

Terminal box

Cable entry

Outer cable diameter, max.4)

Number of main terminals

Cross-section per terminal, max.

Rated current, max.5)

Type

Type

Power

External signals

mm

mm2

A

1PH808

Forced ventilation

gk803

1   M25   1.5

1   O 22 mm6)

20

Phases: 3   M5
Grounding: 2   M5

1   10

50

1PH810

Forced ventilation

gk813

1   M32   1.5

1   O 22 mm6)

24.2

Phases: 3   M5
Grounding: 2   M5

1   16

66

1PH813

Forced ventilation

gk833

1   M40   1.5

1   O 22 mm6)

32

Phases: 3   M6
Grounding: 2   M6

1   35

104


4) Dependent on the design of the metric cable gland.

5) Current-carrying capacity based on EN 60204-1 and IEC 60364-5-52, according to installation type C.

6) Hole with diameter 22 mm, at 90° to signal connection.
























































  © ООО "СК ЭНЕРГО" 2007-2022
  (4872) 700-366
Яндекс.Метрика