Typical speed/power graph for AC motors1)
The graph shows the typical relationship between motor speed and drive power in 1PH7 motors for the following duty types in accordance with IEC 60034-1:
S1: Continuous duty
S6: Continuous duty with intermittent loading and a relative duty factor of 60 % (S6-60 %) or 40 % (S6-40 %) with a maximum duty cycle time of 10 minutes.
S2: Short-time duty with duty period of 30 minutes (S2-30 min) and subsequent standstill.
1PH7 motor |
Rated speed |
Attainable speed for rated power in duty type |
|||
---|---|---|---|---|---|
Type |
n rated |
n 2 2) |
|||
S1 |
S6-60 % |
S6-40 % |
S2-30 min |
||
rpm |
rpm |
rpm |
rpm |
rpm |
|
1PH7101-..F |
1500 |
8200 |
7000 |
6000 |
6500 |
1PH7103-..D |
1000 |
3750 |
3750 |
3100 |
3350 |
1PH7103-..F |
1500 |
5000 |
4600 |
3900 |
4500 |
1PH7103-..G |
2000 |
9000 |
7500 |
6400 |
6900 |
1PH7105-..F |
1500 |
7900 |
6750 |
5750 |
6150 |
1PH7107-..D |
1000 |
5800 |
4800 |
4100 |
4650 |
1PH7107-..F |
1500 |
6500 |
6200 |
5250 |
5650 |
1PH7107-..G |
2000 |
7000 |
7000 |
6900 |
7000 |
1PH7131-..F |
1500 |
6700 |
5500 |
4500 |
5000 |
1PH7133-..D |
1000 |
4700 |
3700 |
2800 |
3450 |
1PH7133-..F |
1500 |
6800 |
5600 |
4500 |
5100 |
1PH7133-..G |
2000 |
6500 |
6500 |
5900 |
6450 |
1PH7135-..F |
1500 |
7500 |
6200 |
5200 |
5650 |
1PH7137-..D |
1000 |
5400 |
4500 |
3600 |
4100 |
1PH7137-..F |
1500 |
7000 |
7000 |
6200 |
6800 |
1PH7137-..G |
2000 |
6000 |
6000 |
5800 |
6000 |
1PH7163-..B |
500 |
2500 |
1900 |
1500 |
1730 |
1PH7163-..D |
1000 |
5800 |
4800 |
4000 |
4400 |
1PH7163-..F |
1500 |
5500 |
5500 |
5500 |
5500 |
1PH7163-..G |
2000 |
3500 |
3500 |
3500 |
3500 |
1PH7167-..B |
500 |
2100 |
1600 |
1250 |
1400 |
1PH7167-..D |
1000 |
6250 |
5200 |
4300 |
4700 |
1PH7167-..F |
1500 |
4500 |
4500 |
4500 |
4500 |
1PH7167-..G |
2000 |
3250 |
3250 |
3250 |
3250 |
1PH7184-..T |
500 |
4500 |
3800 |
3350 |
3350 |
1PH7184-..D |
1000 |
5000 |
4400 |
3600 |
3600 |
1PH7184-..E |
1250 |
5000 |
4680 |
4190 |
3600 |
1PH7184-..F |
1500 |
5000 |
5000 |
5000 |
5000 |
1PH7184-..L |
2500 |
5000 |
5000 |
5000 |
5000 |
1PH7186-..T |
500 |
4800 |
4100 |
3580 |
4000 |
1PH7186-..D |
1000 |
5000 |
4650 |
3850 |
3850 |
1PH7186-..E |
1250 |
5000 |
4260 |
3780 |
3580 |
1PH7224-..C |
700 |
3020 |
2570 |
2290 |
2170 |
1PH7224-..D |
1000 |
4500 |
4500 |
4100 |
3730 |
1PH7224-..F |
1500 |
4500 |
4330 |
4000 |
3890 |
1) For further configuration information, see the 1PH7 Motors Configuration Manual.
2) SINAMICS S120: Values taken from the speed/power graph when using an Active Line Module on a 400 V 3 AC supply system. If you are using a Smart Line Module, and with option for increased maximum speed, proceed in accordance with the 1PH7 Motors Configuration Manual.
2) SIMODRIVE 611: Values taken from the speed/power graph with closed-loop infeed. When using open-loop infeed modules, compliance with the planning guidelines for 1PH7 motors is essential.