The Smart Line Modules in booksize compact format feature the following connections and interfaces as standard: - 1 power connection via screw-type terminals
- 1 connection for the 24 V DC electronics power supply via the 24 V terminal adapter included in the scope of supply
- 1 DC link connection via integrated DC link busbars
- 2 PE (protective earth) connections
- 3 DRIVE‑CLiQ sockets
The status of the Smart Line Modules is indicated via two multi-color LEDs. The signal cable shield can be connected to the Line Module by means of a shield connection terminal, e.g. Weidmüller type KLBÜ 3‑8 SC. The scope of supply of the Smart Line Modules includes: - DRIVE‑CLiQ cable for connection to the adjacent Control Unit on the left for drive control, length 0.11 m (4.33 in)
- 2 blanking plugs for sealing unused DRIVE‑CLiQ sockets
- DRIVE‑CLiQ cable for connecting to the adjacent Motor Module, length 0.21 m (8.3 in)
- Jumper for connecting the 24 V DC busbar to the adjacent Motor Module
- 24 V terminal adapter (X24)
- Connector X21 for digital inputs/outputs
- 1 set of warning signs in 30 languages
- 1 heat conducting foil
|