|
| | | |
Цена на сайте указана розничная в ЕРО без учета НДС. Для уточнения цены и размера предоставляемой скидки - звоните или присылайте заявки | Заказной номер | PG | Описание продукта | Цена | | 7SR2422-2AA11-0BA0 | 184 | DUOBIAS-M TRANSFORMER DIFFERENTIAL RELAY E8 CASE ,6 CT,2EF/REF CT, 1VT 9 BINARY INP. / 6 BINARY OUTP. 16 LEDS MEASURING INPUT: 1/5A, 63,5/110V, 50/60HZ AUXILIARY VOLTAGE: 30 TO 220V DC, BINARY INPUT THRESHOLD 19V DC USB FRONT PORT, RS485 REAR PORT PROTOCOL: IEC 60870-5-103 AND MODBUS RTU (USER SELECTABLE SETTING) AND IEC 61850 PROTECTION FUNCTION: STANDARD VERSION + OPTION B | По запросу | | 7SR2422-2AA77-0CA0 | 184 | DUOBIAS-M TRANSFORMER DIFFERENTIAL RELAY E8 CASE ,6 CT,2EF/REF CT, 1VT 9 BINARY INP. / 6 BINARY OUTP. 16 LEDS MEASURING INPUT: 1/5A, 63,5/110V, 50/60HZ AUXILIARY VOLTAGE: 30 TO 220V DC, BINARY INPUT THRESHOLD 19V DC USB FRONT PORT, RS485 REAR PORT PLUS REAR ELECTR. ETHERNET RJ45 PROTOCOL: IEC 60870-5-103 AND MODBUS RTU AND DNP 3.0 (USER SELECTABLE SETTING) AND IEC 61850 PROTECTION FUNCTION: STANDARD VERSION + OPTION C | По запросу | | 7SR2422-2AA87-0BA0 | 184 | DUOBIAS-M TRANSFORMER DIFFERENTIAL RELAY E8 CASE ,6 CT,2EF/REF CT, 1VT 9 BINARY INP. / 6 BINARY OUTP. 16 LEDS MEASURING INPUT: 1/5A, 63,5/110V, 50/60HZ AUXILIARY VOLTAGE: 30 TO 220V DC, BINARY INPUT THRESHOLD 19V DC USB FRONT PORT, RS485 REAR PORT PLUS REAR OPT. ETHERNET DUPLEX PROTOCOL: IEC 60870-5-103 AND MODBUS RTU AND DNP 3.0 (USER SELECTABLE SETTING) AND IEC 61850 PROTECTION FUNCTION: STANDARD VERSION + OPTION B | По запросу | | 7SR2422-2AA87-0CA0 | 184 | DUOBIAS-M TRANSFORMER DIFFERENTIAL RELAY E8 CASE ,6 CT,2EF/REF CT, 1VT 9 BINARY INP. / 6 BINARY OUTP. 16 LEDS MEASURING INPUT: 1/5A, 63,5/110V, 50/60HZ AUXILIARY VOLTAGE: 30 TO 220V DC, BINARY INPUT THRESHOLD 19V DC USB FRONT PORT, RS485 REAR PORT PLUS REAR OPT. ETHERNET DUPLEX PROTOCOL: IEC 60870-5-103 AND MODBUS RTU AND DNP 3.0 (USER SELECTABLE SETTING) AND IEC 61850 PROTECTION FUNCTION: STANDARD VERSION + OPTION C | По запросу | | 7SR2422-2BA32-0CA0 | 184 | DUOBIAS-M TRANSFORMER DIFFERENTIAL RELAY E8 CASE ,6 CT,2EF/REF CT, 1VT 9 BINARY INP. / 6 BINARY OUTP. 16 LEDS MEASURING INPUT: 1/5A, 63,5/110V, 50/60HZ AUXILIARY VOLTAGE: 30 TO 220V DC, BINARY INPUT THRESHOLD 88V DC USB FRONT PORT, RS485 REAR PORT PLUS REAR RS485 AND IRIG-B PROTOCOL: IEC 60870-5-103 AND MODBUS RTU AND DNP 3.0 (USER SELECTABLE SETTING) PROTECTION FUNCTION: STANDARD VERSION + OPTION C | По запросу | | 7SR2422-2BA77-0AA0 | 184 | DUOBIAS-M TRANSFORMER DIFFERENTIAL RELAY E8 CASE ,6 CT,2EF/REF CT, 1VT 9 BINARY INP. / 6 BINARY OUTP. 16 LEDS MEASURING INPUT: 1/5A, 63,5/110V, 50/60HZ AUXILIARY VOLTAGE: 30 TO 220V DC, BINARY INPUT THRESHOLD 88V DC USB FRONT PORT, RS485 REAR PORT PLUS REAR ELECTR. ETHERNET RJ45 PROTOCOL: IEC 60870-5-103 AND MODBUS RTU AND DNP 3.0 (USER SELECTABLE SETTING) AND IEC 61850 PROTECTION FUNCTION: STANDARD VERSION | По запросу | | 7SR2423-2BA11-0BA0 | 184 | DUOBIAS-M TRANSFORMER DIFFERENTIAL RELAY E10 CASE ,6 CT,2EF/REF CT, 1VT 19 BINARY INP./ 14 BINARY OUTP. 24 LEDS MEASURING INPUT: 1/5A, 63,5/110V, 50/60HZ AUXILIARY VOLTAGE: 30 TO 220V DC, BINARY INPUT THRESHOLD 88V DC USB FRONT PORT, RS485 REAR PORT PROTOCOL: IEC 60870-5-103 AND MODBUS RTU (USER SELECTABLE SETTING) PROTECTION FUNCTION: STANDARD VERSION + OPTION B | По запросу | | 7SR2423-2BA12-0BA0 | 184 | DUOBIAS-M TRANSFORMER DIFFERENTIAL RELAY E10 CASE ,6 CT,2EF/REF CT, 1VT 19 BINARY INP./ 14 BINARY OUTP. 24 LEDS MEASURING INPUT: 1/5A, 63,5/110V, 50/60HZ AUXILIARY VOLTAGE: 30 TO 220V DC, BINARY INPUT THRESHOLD 88V DC USB FRONT PORT, RS485 REAR PORT PROTOCOL: IEC 60870-5-103 AND MODBUS RTU AND DNP 3.0 (USER SELECTABLE SETTING) PROTECTION FUNCTION: STANDARD VERSION + OPTION B | По запросу | | 7SR2423-2BA87-0CA0 | 184 | DUOBIAS-M TRANSFORMER DIFFERENTIAL RELAY E10 CASE ,6 CT,2EF/REF CT, 1VT 19 BINARY INP./ 14 BINARY OUTP. 24 LEDS MEASURING INPUT: 1/5A, 63,5/110V, 50/60HZ AUXILIARY VOLTAGE: 30 TO 220V DC, BINARY INPUT THRESHOLD 88V DC USB FRONT PORT, RS485 REAR PORT PLUS REAR OPT. ETHERNET DUPLEX PROTOCOL: IEC 60870-5-103 AND MODBUS RTU AND DNP 3.0 (USER SELECTABLE SETTING) AND IEC 61850 PROTECTION FUNCTION: STANDARD VERSION + OPTION C | По запросу |
|
|