InterfacesDisplay and diagnostics
Onboard I/Os
Communication
Data backup
Additional interfaces
MountingSIMOTION D410-2 can be directly plugged into the SINAMICS S120 Power Module in blocksize format. Alternatively, the SIMOTION D410-2 can be mounted on a mounting plate (to be ordered separately) and connected to the Power Module via DRIVE-CLiQ. In this case, the CUA31/CUA32 Control Unit Adapter has to be connected to the Power Module. No more than one Control Unit Adapter can be connected to the SIMOTION D410-2. Note: It is not possible to use the Safety Integrated Extended Functions via the onboard terminals (F-DI, F-DO) when the Power Module is connected via CUA31/CUA32. Power Modules in AC/AC chassis format are connected to the SIMOTION D410-2 over the DRIVE-CLiQ interface. Motor Modules in booksize format cannot be connected to SIMOTION D410-2. A SIMOTION D410-2 mounted on the mounting plate can also be operated without a Power Module, e.g.
Data storage/data backupThe SIMOTION D410-2 Control Units store the retentive process data permanently in a manner that requires no maintenance (refer to technical data for memory size). The real-time clock is backed up for several days via a SuperCap. The runtime software, user data and user programs are backed up on the SIMOTION CompactFlash card. The retentive process data of the Control Unit can also be stored on this CompactFlash card via system command, e.g. if spare parts are required. Connectable I/OsPROFINET IO: (D410‑2 DP/PN only)
PROFIBUS DP:
DRIVE‑CLiQ: Modules from the SINAMICS range:
|