Power requirement At 24 V DC, max. without taking account of digital outputs and DRIVE-CLiQ supply | 0.8 A for CU305 incl. 350 mA for HTL encoder + 0.5 A for PM340 Power Module |
Conductor cross-section, max. | 2.5 mm2 |
Fuse protection, max. | 20 A |
Digital inputs | In accordance with IEC 61131‑2 Type 1 3 floating fail-safe inputs 5 floating digital inputs |
| -3 ... +30 V |
- Low level (an open digital input is interpreted as "low")
| -3 ... +5 V |
| 15 ... 30 V |
- Current consumption at 24 V DC, typ.
| 6 mA |
- Delay time of digital inputs 1), approx.
| |
| 15 Ојs |
| 55 Ојs |
- Delay time of high-speed digital inputs 1), approx.
(high-speed digital inputs can be used for position detection)
| |
| 5 Ојs |
| 5 Ојs |
- Conductor cross-section, max.
| 1.5 mm2 |
Digital outputs (continuously short-circuit-proof) | 1 fail-safe digital output 4 bidirectional non-floating digital inputs/digital outputs |
| 24 V DC |
- Load current per digital output 2), max.
| 100 mA |
| 150 Ојs |
- Conductor cross-section, max.
| 1.5 mm2 |
Analog input | -10 ... +10 V Resolution 12 bits + sign |
| 15 kО© |
Encoder evaluation | - Incremental encoder TTL/HTL
- SSI encoder without incremental signals
|
| 24 V DC/0.35 A or 5 V DC/0.35 A |
| 500 kHz |
| 100 ... 250 kBaud depending on cable length |
- Resolution absolute position SSI
| 30 bit |
| |
| 100 m (328 ft) (only bipolar signals permitted) 3) |
| 100 m (328 ft) for unipolar signals 300 m (984 ft) for bipolar signals 3) |
| 100 m (328 ft) |
Power loss | <20 W |
PE connection | M5 screw |
Dimensions | |
| 73 mm (2.87 in) |
| - for CU305 PN: 195 mm
- for CU305 DP: 183.2 mm
|
| - for CU305 PN: 71 mm
- for CU305 DP: 55 mm
|
Weight, approx. | 0.95 kg (2.09 lb) |
Approvals | cULus |