Power | |
| 50 kW |
| 250 kW |
| 200 kW |
| 100 kW |
Activation thresholds Adjustable via DIP switch | 774 V (factory setting) or 673 V |
Cable length to braking resistor, max. | 50 m (164 ft) |
Digital inputs In accordance with IEC 61131-2 Type 1 | |
| -3 ... +30 V |
- Low level
(an open digital input is interpreted as "low")
| -3 ... +5 V |
| 15 ... 30 V |
- Current consumption at 24 V DC, typ.
| 10 mA |
- Conductor cross-section, max.
| 1.5 mm2 |
Digital outputs continuously short-circuit-proof | |
| 24 V DC |
- Load current per digital output, max.
| 500 mA |
- Conductor cross-section, max.
| 1.5 mm2 |
R1/R2 connection | M8 screw |
- Conductor cross-section, max.
| 50 mm2 |
Weight, approx. | 7.3 kg (16.10 lb) |
Approvals | cURus |
Suitable for installation in a PM240 Power Module | Frame size FSGX |