The following components can be connected to the SINAMICS S120 Combi drive system: - SINUMERIK 828D BASIC
- SINUMERIK 828D
- 3 or 4 spindles/feed motors
- 3 or 4 motor encoders
- 3 or 4 direct encoders via DMC20
- Direct spindle encoder directly to TTL or sin/cos via SMC20
- External fan module
- Up to two additional SINAMICS S120 Motor Modules in booksize compact format via DC link connection and 24 V DC busbars
- Braking Module with braking resistor via DC link connection
- Control Supply Module via DC link connection and 24 V DC busbars
- One safe motor brake control
- 5 or 6 DRIVE‑CLiQ sockets
- 24 V electronics power supply via connector
- 1 safe standstill input for the infeed (Enable Pulses)
- 1 safe standstill input for the spindle and feeds (Enable Pulses)
- 1 temperature sensor input for the spindle
- PE connections
The scope of supply of the SINAMICS S120 Combi Power Modules includes: - SINAMICS S120 Combi Power Module
- Accessories pack consisting of:
- 4 DRIVE‑CLiQ dust-proof blanking plugs
- Connector X224 for the electronics power supply
- Connector X11 for motor brake control
- Connector X21 Enable Pulses infeed
- Connector X22 Enable Pulses temperature sensor - axes.
- 5 shield terminals for power cables
- Shield terminal for signal cable
|