Rear enclosure part including accessories for mounting the firing pulse transformer module and/or fuse monitoring module for a parallel connection | Set of loose parts | | 6RY1805‑0CM00 |
Screws, stud bolts, and snap-on parts to externally mount module parts | Set of loose parts | | 6RY1807‑0CM00 |
Pre-fabricated connection set ribbon cable: To connect the two cradles when separately mounted | 2 x 26-core ribbon cables​ shielded (3 m long) | from X21A, X22A on PCB -A7109- to X21A, X22A on PCB -A7043- | 6RY1807‑0CM01 |
1 x 10-core ribbon cable shielded (3 m long) | from X23B on PCB -A7109- to X23B on PCB -A7118- |
1 x 20-core ribbon cable shielded (3 m long) | from XF1 on PCB -A7109- to XF1 on PCB -A7116- |
1 x RJ45 patch cable shielded (3 m long) | from X45 on PCB -A7109- to X45 on PCB -A7117- |
Pre-fabricated connection set ribbon cable: To connect the two cradles when separately mounted | 2 x 26-core ribbon cables​ shielded (10 m long) | from X21A, X22A on PCB -A7109- to X21A, X22A on PCB -A7043- | 6RY1807‑0CM02 |
1 x 10-core ribbon cable shielded (10 m long) | from X23B on PCB -A7109- to X23B on PCB -A7118- |
1 x 20-core ribbon cable shielded (10 m long) | from XF1 on PCB -A7109- to XF1 on PCB -A7116- |
1 x RJ45 patch cable shielded (10 m long) | from X45 on PCB -A7109- to X45 on PCB -A7117- |
Pre-fabricated connection set for current transformer | 2 x 2-core twisted cables​​ (2 m long) | from XB on PCB -A7109- to the current transformers | 6RY1707‑0CM03 1) |
Pre-fabricated connection set for current transformer | 2 x 2-core cables shielded (10 m long) | from XB on PCB -A7109- to the current transformers | 6RY1707‑0CM04 1) |
Pre-fabricated connection set for heat sink temperature sensing | 1 x 2-core cable shielded (10 m long) | from XT6 on PCB -A7109- to temperature sensor on the heat sink | 6RY1707‑0CM05 1) |
Pre-fabricated connection set for firing pulse | Connection set for 12 x 2-core twisted cables (3 m long) | from XIMP11, XIMP12, XIMP13, XIMP14, XIMP15, XIMP16, XIMP21, XIMP22, XIMP23, XIMP24, XIMP25, XIMP26 to the thyristors | 6RY1707‑0CM06 1) |
Pre-fabricated connection set for fuse monitoring | 6 x 2-core twisted cables (10 m long) | from XS1_5, XS2_5, XS3_5, XS4_5, XS5_5, XS6_5, XS7_5, XS8_5, XS9_5, XS10_5, XS11_5, XS12_5 or XS1_4, XS2_4, XS3_4, XS4_4, XS5_4, XS6_4, XS7_4, XS8_4, XS9_4, XS10_4, XS11_4, XS12_4 or XS1_3, XS2_3, XS3_3, XS4_3, XS5_3, XS6_3, XS7_3, XS8_3, XS9_3, XS10_ | 6RY1807‑0CM07 |
Pre-fabricated connection set for voltage sensing | 1 x 3-core twisted cable U-V-W (3 m long) 1 x 2-core twisted cable C-D (3 m long) | from XU6, XV6, XW6 or XU5, XV5, XW5 or XU4, XV4, XW4 or XU3, XV3, XW3 or XU2, XV2, XW2 or XU1, XV1, XW1 depending on the voltage (5.6 V, 50 V, 125 V, 250 V, 575 V or 1000 V) to supply XC6, XD6 or XC5, XD5 or XC4, XD4 or XC3, XD3 or XC2, XD2 | 6RY1807‑0CM08 |
Pre-fabricated connection set for controlling the firing pulse transformers | 12 x 2-core twisted cables​ (1 m long) | from XIMP1, XIMP4 or XIMP2, XIMP5 or XIMP3, XIMP6 on PCB -A7043- (side sections) to firing pulse transformer modules (single boards) with terminals X11, X12, X13, X14, X15, X16, X21, X22, X23, X24, X25, X26 | 6RY1707‑0CM13 1) |
Pre-fabricated connection set for controlling firing pulse transformers | 2 x 12-core cables shielded (10 m long) | from XIMP1, XIMP4 and/or XIMP2, XIMP5 and/or XIMP3, XIMP6 on PCB -A7043- to external firing pulse transformers | 6RY1707‑0CM10 1) |
Pre-fabricated connection set for mounting cradles next to each other | 2 x 26-core ribbon cables​ shielded (0.68 m long) | from X21A, X22A on PCB -A7109- to X21A, X22A on PCB -A7043- | 6RY1807‑0CM11 |
1 x 10-core ribbon cable shielded (0.5 m long) | from X23B on PCB -A7109- to X23B on PCB -A7118- |
1 x 20-core ribbon cable shielded (0.76 m long) | from XF1 on PCB -A7109- to XF1 on PCB -A7116- |
1 x RJ45 patch cable shielded (1 m long) | from X45 on PCB -A7109- to X45 on PCB -A7117- |
Fuse monitoring distribution module for parallel connection of fuse monitors | Module including 3 m ribbon cable to connect to the SINAMICS DCM Control Module; can be snapped onto mounting rails according to DIN EN 50022-35x7.5 | X23A on Power Interface Control Module and fuse monitor | 6RY1803-0CM26 |