Communications functionsIt is possible to access important internal signals and parameters of both the basic converter and T100 via the USS interface on the basic unit or the T100 board. The access method and reactions of the T100 are identical to those of the SIMOREG basic unit. The T100 has its own parameter memory and can be parameterized via the PMU operator control and parameterization panel, the OP1S operator panel or a PC with SIMOVIS installed. The PC with SIMOVIS is connected to the USS interface on the SIMOREG unit. All important internal signals of the T100 can be monitored by means of display parameters (multimeter function). The T100 features three diagnostic LEDs which indicate the following operating states: 1. T100 is operating correctly in cyclical mode. 2. Data exchange between T100 and SIMOREG is OK. 3. Data exchange between T100 and the communication board is OK. Note All the software functions described here are contained in the MS100 “Universal Drive” software module. The module is a 40-pin EPROM submodule that must be ordered separately and inserted in the specially provided receptacle on the T100 board. |