6XV1822-5BE30Öåíà íà ñàéòå óêàçàíà ðîçíè÷íàÿ â ÅÂÐÎ áåç ó÷åòà ÍÄÑ. Äëÿ óòî÷íåíèÿ öåíû è ðàçìåðà ïðåäîñòàâëÿåìîé ñêèäêè - çâîíèòå èëè ïðèñûëàéòå çàÿâêè | Çàêàçíîé íîìåð | Âåñ | PG | Îïèñàíèå ïðîäóêòà | Öåíà | | 6XV1822-5BE30 | 0.14 | 5K1 | SIMATIC NET, 7/8 ÏÐÈÑÎÅÄÈÍÈÒÅËÜÍÛÉ ÊÀÁÅËÜ ÄËß ÏÈÒÀÍÈß ET200, ÑÎÁÐÀÍÍÛÉ ÊÀÁÅËÜ Ñ ÄÂÓÌß 7/8 ØÒÅÊÊÅÐÀÌÈ, 5-PIN, 0.3 M | Ïî çàïðîñó |
For SINAMICS G120D distributed frequency inverters, the following supplementary system components are always required or are available depending on the intended application. Description | Order |
|---|
Intelligent Operator Panel IOP‑2 Handheld 1) | Application-dependent | - RS232 connecting cable 1)
| Application-dependent | Memory cards | Application-dependent | PC inverter connection kit 2 (mini USB interface cable for communication with a PC) | Application-dependent | STARTER commissioning tool | Application-dependent | SINAMICS Startdrive commissioning tool | Application-dependent | Connecting cables for the Control Unit | Â | - PROFINET connecting cable
| Application-dependent | - PROFIBUS connecting cable
| Application-dependent | - Connecting cables/connectors for supplying the Control Unit with 24 V DC power
| Always required | - Connecting cables and connectors for digital inputs and outputs
| Application-dependent | - Connecting cables and connectors for encoders and analog inputs
| Application-dependent | Connecting cables for Power Modules | Â | - Connecting cables pre-assembled at one end and connector sets to connect to the line supply
| Always required | - Motor cables pre-assembled at one end and connector sets to connect the Power Module to the motor
| Always required | - Power bus distribution 400Â V in IP65 degree of protection
| Application-dependent |
1) For use of the IOP‑2 Handheld in combination with SINAMICS G110D, SINAMICS G120D, SINAMICS G110M and SIMATIC ET 200pro FC‑2, the RS232 connecting cable with optical interface is required (Article No.: 3RK1922‑2BP00). The cable must be ordered separately. Intelligent Operator Panel IOP‑2 Handheld IOP‑2 Handheld for mobile use The Intelligent Operator Panel IOP‑2 Handheld is a very user-friendly and powerful operator panel for commissioning and diagnostics as well as local operator control and monitoring of SINAMICS G110D, SINAMICS G120D, SINAMICS G110M and SIMATIC ET 200pro FC‑2 distributed inverters. The IOP‑2 Handheld supports both newcomers and drive experts. Thanks to the membrane keyboard with a central sensor control field, the high-contrast color displays, the menu-based operation and the application wizards, it is easy to commission standard drives. A drive can be essentially commissioned without having to use a printed parameter list – as the parameters are displayed in plain text, and explanatory help texts and a parameter filtering function are provided. Application wizards interactively guide you when commissioning important applications such as conveyor technology, pumps, fans and compressors. There is a basic commissioning wizard for general commissioning. Up to two process values can be graphically visualized and up to four process values can be numerically visualized on the status screen/display. Process values can also be displayed in technological units. The IOP‑2 Handheld supports standard commissioning of identical drives. For this purpose, a parameter list can be copied from an inverter into the IOP‑2 Handheld and downloaded into other drive units of the same type as required. In addition to the IOP‑2, the IOP‑2 Handheld includes a housing with rechargeable batteries, a charging unit, an RS232 connecting cable, and a USB cable. The charging unit is supplied with connector adapters for Europe, the US and UK. When the batteries are fully charged, the operating time is up to 10 hours. To connect the IOP‑2 Handheld to SINAMICS G110D, SINAMICS G120D, SINAMICS G110M and SIMATIC ET 200pro FC‑2, the RS232 connecting cable with optical interface is required in addition. Updating the IOP‑2 Handheld The IOP‑2 Handheld can be updated and expanded using the integrated USB interface. Data to support future drive systems can be transferred from the PC to the IOP‑2 Handheld. Further, the USB interface allows user languages and wizards that will become available in the future to be subsequently downloaded and the firmware to be updated for the IOP‑2 Handheld 1). 1) Information on updates for the IOP‑2 Handheld is available at https://support.industry.siemens.com/cs/document/67273266 Selection and ordering data Description | Article No. |
|---|
IOP‑2 Handheld For use with SINAMICS G120 SINAMICS G120C SINAMICS G120P SINAMICS G110D SINAMICS G120D SINAMICS G110M SIMATIC ET 200pro FC‑2 Included in the scope of delivery: - IOP‑2
- Handheld housing
- Rechargeable batteries (4 × AA)
- Charging unit (international)
- RS232 connecting cable
3Â m (9.84Â ft) long, can be used in combination with SINAMICSÂ G120 SINAMICSÂ G120C SINAMICSÂ G120P - USB cable
1Â m (3.28Â ft) long
| 6SL3255-0AA00-4HA1 | RS232 connecting cable 2.5 m (8.20 ft) long, with optical interface for connecting the IOP‑2 Handheld to SINAMICS G110D SINAMICS G120D SINAMICS G110M SIMATIC ET 200pro FC‑2 | 3RK1922-2BP00 |
Technical specifications  | IOP‑2 Handheld 6SL3255-0AA00-4HA1 |
|---|
Display | High-contrast color display, a variety of display options | | 320 × 240 pixels | Operator panel | Membrane keyboard with central sensor control field | Operating languages | English, German, French, Italian, Spanish, Portuguese, Dutch, Swedish, Finnish, Russian, Czech, Polish, Turkish, Chinese Simplified | Ambient temperature |  | - During transport and storage
| -20 ... +55 °C (-4 ... +131 °F) | | 0 ... 40 °C (32 ... 104 °F) | Humidity | Relative humidity < 95 %, non-condensing | Degree of protection | IP20 | Dimensions (H × W × D) | 195.04 × 70 × 37.58 mm (7.68 × 2.76 × 1.48 in) | Weight, approx. | 0.724 kg (1.6 lb) | Compliance with standards | CE, RCM, cULus, EAC, KCC-REM-S49-SINAMICS |
Memory cards SINAMICS SD memory card The parameter settings for an inverter can be stored on the SINAMICS SD memory card. When service is required, e.g. after the inverter has been replaced and the data have been downloaded from the memory card, the drive system is immediately ready for use again. - Parameter settings can be written from the memory card to the inverter or saved from the inverter to the memory card.
- Up to 100Â parameter sets can be stored.
- The memory card supports standard commissioning without the use of the Intelligent Operator Panel IOP‑2 Handheld or the STARTER and SINAMICS Startdrive commissioning tools.
- If firmware is stored on the memory card and a Control Unit is installed, the firmware can be upgraded/downgraded during power-up 1).
Note: The memory card is optional, but it facilitates inverter replacement. 1) You can find more information about firmware upgrades/downgrades on the Internet at https://support.industry.siemens.com/cs/document/67364620 Selection and ordering data Description |  | Article No. |
|---|
SINAMICS SD card 512 MB |  | 6SL3054-4AG00-2AA0 | Optional firmware memory cards | SINAMICS SD card 512 MB + firmware V4.7 SP3 (Multicard V4.7 SP3) |  | 6SL3054-7TB00-2BA0 | SINAMICS SD card 512 MB + firmware V4.7 SP6 (Multicard V4.7 SP6) |  | 6SL3054-7TD00-2BA0 | SINAMICS SD card                                                                        512 MB + firmware V4.7 SP9 (Multicard V4.7 SP9) | NEW | 6SL3054-7TE00-2BA0 |
For an overview and more information on all available firmware versions, see https://support.industry.siemens.com/cs/document/67364620 PC inverter connection kit 2 (mini USB interface cable for communication with a PC)For controlling and commissioning an inverter directly from a PC via a point-to-point connection if the appropriate software (STARTER commissioning tool 1), V4.3 and higher, or SINAMICS Startdrive) has been installed. Selection and ordering data Description | Article No. |
|---|
PC inverter connection kit 2 USB cable (3 m/9.84 ft long) for - SINAMICSÂ G120C
- SINAMICSÂ G120 Control Units
- SINAMICSÂ G110M Control Units
- SINAMICSÂ G120D Control Units
| 6SL3255-0AA00-2CA0 |
STARTER commissioning toolThe STARTER commissioning tool (V4.3 and higher) supports the commissioning and maintenance of SINAMICSÂ G120D inverters. The operator guidance combined with comprehensive, user-friendly functions for the relevant drive solution allow you to commission the device quickly and easily. Selection and ordering data Description | Article No. |
|---|
STARTER commissioning tool 1) on DVD‑ROM | 6SL3072-0AA00-0AG0 |
1) The STARTER commissioning tool is also available on the Internet at http://www.siemens.com/starter An overview of all available accessories (e.g. connectors and cables) can be found under the following link: http://www.siemens.com/distributeddrives-supplementaryproducts SINAMICS Startdrive commissioning toolThe SINAMICS Startdrive commissioning tool (V13 and higher) supports the commissioning and maintenance of SINAMICS G120D inverters. SINAMICS Startdrive is part of the TIA Portal engineering platform. It supports the intuitive integration of SINAMICS drives in automation. The same operator control concept, the elimination of interfaces and a high degree of user-friendliness make it possible to quickly integrate SINAMICS into an automation process and start it up with the TIA Portal. The TIA Portal with SINAMICS Startdrive offers you a totally integrated engineering platform for the complete application from the project engineering phase through to commissioning and diagnostics. Selection and ordering data Description | Article No. |
|---|
SINAMICS Startdrive commissioning tool 1) on DVD‑ROM | 6SL3072-4DA02-0XG0 |
1) The SINAMICS Startdrive commissioning tool is also available on the Internet at https://support.industry.siemens.com/cs/document/68034568 Â An overview of all available accessories (e.g. connectors and cables) can be found under the following link: http://www.siemens.com/distributeddrives-supplementaryproducts Connecting cables for the Control UnitPROFINET connecting cableFlexible plug-in cables and plug-in connectors that can be assembled in the field for transmission of data (up to 100Â Mbit/s) between Industrial Ethernet stations with IP65 degree of protection. Selection and ordering data Description | Article No. |
|---|
IE connecting cable M12‑180/M12‑180 Pre-assembled IE FC TP trailing cable GP 2 x 2 PROFINET type C with two 4-pole M12 plugs (4-pole, D-coded), IP65/IP67 degree of protection, UL, plug/plug connector (IN/OUT) Length: |  | | 6XV1870-8AE30 | | 6XV1870-8AE50 | | 6XV1870-8AH10 | | 6XV1870-8AH15 | | 6XV1870-8AH20 | | 6XV1870-8AH30 | | 6XV1870-8AH50 | | 6XV1870-8AN10 | | 6XV1870-8AN15 | IE M12 Plug PRO For assembly in the field, M12 plug-in connector (D-coded), metal enclosure, UL, fast connection method, plug connector |  | | 6GK1901-0DB20-6AA0 | | 6GK1901-0DB20-6AA8 | | 3RK1902-2DA00 | RJ45 PLUG PRO connector For on-site assembly for CU240D‑2 PN‑F PP or CU250D‑2 PN‑F PP Control Unit, UL 1 package = 1 unit |  | | 6GK1901-1BB10-6AA0 | SIMATIC NET POF/PCF cables (fiber optic) For CU240D‑2 PN‑F FO and CU250D‑2 PN‑F FO Coded cables for assembly in the field (sold by the meter) |  | - POF standard cable GP 980/1000
Minimum order quantity: 20Â m (66Â ft)
| 6XV1874-2A | - POF trailing cable 980/1000
Minimum order quantity: 20Â m (66Â ft)
| 6XV1874-2B | - PCF standard cable GP 200/230
With UL approval Minimum order quantity: 20Â m (66Â ft)
| 6XV1861-2D | - PCF trailing cable 200/230
With UL approval Minimum order quantity: 20Â m (66Â ft)
| 6XV1861-2C | Connectors for fiber-optic cables POF/PCF plug-in connectors for assembly in the field | Â | - IE SC RJ POF PLUG PRO (1Â unit)
| 6GK1900-0MB00-6AA0 | - IE SC RJ PCF PLUG PRO (1Â unit)
| 6GK1900-0NB00-6AA0 |
PROFIBUS connecting cableFlexible plug-in cables/connectors for transmission of data (up to 12Â Mbit/s) from PROFIBUS stations. Selection and ordering data Description | Article No. |
|---|
PROFIBUS M12 plug-in cable Pre-assembled with two 5-pole M12 plug/socket connectors, UL Length: |  | | 6XV1830-3DE30 | | 6XV1830-3DE50 | | 6XV1830-3DH10 | | 6XV1830-3DH15 | | 6XV1830-3DH20 | | 6XV1830-3DH30 | | 6XV1830-3DH50 | | 6XV1830-3DN10 | | 6XV1830-3DN15 | PROFIBUS M12 connector 5-pole, B-coded, metal enclosure, 1 package = 5 units |  | | 6GK1905-0EA00 | | 6GK1905-0EB00 |
Connecting cables/connectors for supplying the Control Unit with 24 V DC powerSelection and ordering data Description | Article No. |
|---|
7/8" plug-in cable For power supply, pre-assembled with two 5-pole 7/8" plug/socket connectors, UL 5 × 1.5 mm2 Length: |  | | 6XV1822-5BE30 | | 6XV1822-5BE50 | | 6XV1822-5BH10 | | 6XV1822-5BH15 | | 6XV1822-5BH20 | | 6XV1822-5BH30 | | 6XV1822-5BH50 | | 6XV1822-5BN10 | | 6XV1822-5BN15 | 7/8" plug-in connector 5-pole, B-coded, plastic enclosure, 1 package = 5 units |  | | 6GK1905-0FA00 | - Female contact insert (IN)
| 6GK1905-0FB00 | POWER PLUG PRO plug-in connector For the CU2x0D-2 PN-F PP/FO 5-pole push‑pull power-plug for on-site assembly 1 Pack = 1 unit |  | | 6GK1907-0AB10-6AA0 |
Connecting cables and connectors for digital inputs and outputsSelection and ordering data Description | Article No. |
|---|
M12 plug-in cable With PUR sheath, to connect digital sensors and actuators, pre-assembled at one end, angled, plug connector, 5-pole, 5 × 0.34 mm2, UL Length: |  | | 3RK1902-4HB15-5AA0 | | 3RK1902-4HB50-5AA0 | | 3RK1902-4HC01-5AA0 | M12 connector For screw mounting, 5-pole screw-type connection max. 0.75 mm2, A-coded, max. 4 A, UL, plug connector |  | | 3RK1902-4BA00-5AA0 | | 3RK1902-4DA00-5AA0 |
Connecting cables and connectors for encoders and analog inputsSelection and ordering data Description | Ordering (see Solution Partner) |
|---|
M12 cable connector 8-pole plug connector |  | | Ordered from and supplied by KnorrTec | | Ordered from and supplied by KnorrTec | M12 plug-in cable Pre-assembled at one end, straight, plug connector, 8-pole, 4 × 2 × AWG24, shielded, PUR gray, suitable for trailing cables, for HTL and SSI encoders Length: |  | | Ordered from and supplied by KnorrTec | | Ordered from and supplied by KnorrTec | | Ordered from and supplied by KnorrTec | M12 plug-in cable Pre-assembled at both ends, 8-pole M12 male connector to 12-pole M23 socket, 4 × 2 × AWG24, shielded, PUR gray, suitable for trailing cables - HTL plug-in cable
- SSI plug-in cable
Length: |  | | Ordered from and supplied by KnorrTec | | Ordered from and supplied by KnorrTec | | Ordered from and supplied by KnorrTec | T distribution piece To connect two analog inputs 8-pole M12 male connector to 2 × 4-pole M12 socket, angled | Ordered from and supplied by KnorrTec |
Connecting cables for Power ModulesConnecting cables pre-assembled at one end and connector sets to connect to the line supplySelection and ordering data Description | Article No. |
|---|
Connecting cable pre-assembled at one end Power supply cable, open at one end, for HAN Q4/2, angled, 4 × 4 mm2 |  | | 3RK1911-0DB13 | | 3RK1911-0DB33 | Connector set for the power supply HAN Q4/2 |  | | 3RK1911-2BE50 | | 3RK1911-2BE10 | | 3RK1911-2BE30 |
Motor cables pre-assembled at one end and connector sets to connect the Power Module to the motorSelection and ordering data Motor cables pre-assembled at one end For motors with brake and temperature sensor with HANÂ Q8 connector, shielded | Article No. (HTG: supplied by Harting) (ZKT: supplied by KnorrTec) |
|---|
Cross-section | 4 × 1.5 mm2 2 × (2 × 0.75 mm2) | 4 × 2.5 mm2 2 × (2 × 0.75 mm2) | 4 × 4 mm2 2 × 1 mm2 + 2 × 1.5 mm2 | | HTG: 61 88 201 0288 | HTG: 61 88 201 0291 | HTG: 61 88 201 0303 |  | ZKT: 70020501000150 | ZKT: 70009601000150 | ZKT: 70017001000150 | | HTG: 61 88 201 0289 | HTG: 61 88 201 0292 | HTG: 61 88 201 0304 |  | ZKT: 70020501000300 | ZKT: 70009601000300 | ZKT: 70017001000300 | | HTG: 61 88 201 0290 | HTG: 61 88 201 0293 | HTG: 61 88 201 0305 |  | ZKT: 70020501000500 | ZKT: 70009601000500 | ZKT: 70017001000500 | | HTG: 61 88 201 0299 | HTG: 61 88 201 0301 | HTG: 61 88 201 0306 |  | ZKT: 70020501001000 | ZKT: 70009601001000 | ZKT: 70017001001000 | Connector set for motor cable HAN Q8, shielded |  |  | HTG: 61 83 401 0131 | HTG: 61 83 401 0132 | HTG: 61 83 401 0133 |  | ZKT: 10032001 | ZKT: 10032011 | ZKT: 10032021 |
Power bus distribution 400Â V in IP65 degree of protectionSelection and ordering data Description | Ordering (see Solution Partner) |
|---|
Power T clamp connector for 2.5 ... 6 mm2 With attached 7-pole connector, female contact insert, grommet housing, UL Seals for various cable cross-sections must be ordered separately | Ordered from and supplied by Harting | T clamp connector Completely pre-assembled | Ordered from and supplied by KnorrTec | T distributor box, IDC connection power cable Pre-assembled, UL, uncut power cable, 2.5 ... 6 mm2 Push-in connection: 1.5 ... 6 mm2 Seals for various cable cross-sections must be ordered separately | Ordered from and supplied by Weidmüller | Y distributor For direct connection of 400 V supply line, HAN Q4/2, conductor cross-section 1.5 ... 4 mm2 | Ordered from and supplied by Harting |
|
|