SIPLUS analog inputs

Article number

6AG1134-6HD00-7BA1

6AG1134-6GD00-7BA1

6AG1134-6TD00-2CA1

SIPLUS ET 200SP AI 4xU/I 2-wire ST

SIPLUS ET 200SP AI 4xI 2-/4-wire ST

SIPLUS ET 200SP AI 4XI 2-WIRE 4...20MA H

General information

 

 

 

Product type designation

AI 4xU/I 2-wire ST

AI 4xI 2-/4-wire ST

AI 4xI 2-wire 4 ... 20 mA HART

Product function

 

 

 

  • ? I&M data

Yes

Yes

Yes; I&M0 to I&M3

  • ? Measuring range scalable

No

Engineering with

 

 

 

  • ? STEP 7 TIA Portal configurable/integrated as of version

V11 SP2 with HSP0024 / -

V11 SP2 with HSP0024 / -

V13 SP1

  • ? STEP 7 configurable/integrated as of version

V5.5 SP2 with GSD file / -

V5.5 SP2 with GSD file / -

V5.5 SP4 and higher

  • ? PCS 7 configurable/integrated as of version

V8.1 SP1

  • ? PROFIBUS as of GSD version/GSD revision

GSD Revision 5

  • ? PROFINET as of GSD version/GSD revision

GSDML V2.3

Operating mode

 

 

 

  • ? Oversampling

No

  • ? MSI

No

CiR – Configuration in RUN

 

 

 

Reparameterization possible in RUN

Yes

Calibration possible in RUN

No

Supply voltage

 

 

 

Type of supply voltage

DC

Rated value (DC)

24 V

24 V

24 V

Reverse polarity protection

Yes

Yes

Yes

Analog inputs

 

 

 

Number of analog inputs

4; > 60 °C max. 1x +/- 20 mA or 4x +/- 10 V permissible

4; > 60 °C max. 1x +/- 20 mA permissible

4; Differential inputs

permissible input voltage for voltage input (destruction limit), max.

30 V

permissible input current for current input (destruction limit), max.

50 mA

50 mA

50 mA

Cycle time (all channels), min.

Sum of the basic conversion times and additional processing times (depending on the parameterization of the active channels)

Sum of the basic conversion times and additional processing times (depending on the parameterization of the active channels)

Input ranges (rated values), voltages

 

 

 

  • ? 0 to +10 V

Yes; 15 bit

  • ? 1 V to 5 V

Yes; 15 bit

  • ? -10 V to +10 V

Yes; 16 bit incl. sign

  • ? -5 V to +5 V

Yes; 16 bit incl. sign

Input ranges (rated values), currents

 

 

 

  • ? 0 to 20 mA

Yes; 15 bit

Yes; 15 bit

No

  • ? -20 mA to +20 mA

Yes; 16 bit incl. sign

No

  • ? 4 mA to 20 mA

Yes; 15 bit

Yes; 15 bit

Yes; 15 bit + sign

Cable length

 

 

 

  • ? shielded, max.

200 m

200 m

800 m

Analog value generation for the inputs

 

 

 

Integration and conversion time/resolution per channel

 

 

 

  • ? Resolution with overrange (bit including sign), max.

16 bit

16 bit

16 bit

  • ? Integration time, parameterizable

Yes

Yes

Yes; channel by channel

  • ? Interference voltage suppression for interference frequency f1 in Hz

16.6 / 50 / 60 Hz

16.6 / 50 / 60 Hz

10 / 50 / 60 Hz

  • ? Conversion time (per channel)

180 / 60 / 50 ms

180 / 60 / 50 ms

Smoothing of measured values

 

 

 

  • ? Number of smoothing levels

4; None; 4/8/16 times

  • ? parameterizable

Yes

Yes

Yes

Encoder

 

 

 

Connection of signal encoders

 

 

 

  • ? for voltage measurement

Yes

No

  • ? for current measurement as 2-wire transducer

Yes

Yes

Yes

  • Burden of 2-wire transmitter, max.

650 ?

650 ?

  • ? for current measurement as 4-wire transducer

Yes

Errors/accuracies

 

 

 

Basic error limit (operational limit at 25 °C)

 

 

 

  • ? Voltage, relative to input range, (+/-)

0.3 %

  • ? Current, relative to input range, (+/-)

0.3 %

0.3 %

0.3 %

Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency

 

 

 

  • ? Series mode interference (peak value of interference < rated value of input range), min.

70 dB

70 dB

60 dB

  • ? Common mode voltage, max.

10 V

10 V

  • ? Common mode interference, min.

90 dB

90 dB

Isochronous mode

 

 

 

Isochronous operation (application synchronized up to terminal)

No

Interrupts/diagnostics/status information

 

 

 

Diagnostics function

Yes

Yes

Yes

Alarms

 

 

 

  • ? Diagnostic alarm

Yes

Yes

Yes

  • ? Limit value alarm

Yes

Diagnostic messages

 

 

 

  • ? Monitoring the supply voltage

Yes

Yes

Yes

  • ? Wire-break

Yes; at 4 to 20 mA

Yes; at 4 to 20 mA

Yes; channel by channel

  • ? Short-circuit

Yes; with 1 to 5 V or 2-wire mode: Short-circuit of the encoder supply to ground or of an input to the encoder supply

Yes; 2-wire mode: Short-circuit of the encoder supply to ground or of an input to the encoder supply

Yes; Channel-by-channel, short-circuit of the encoder supply to ground or of an input to the encoder supply

  • ? Group error

Yes

  • ? Overflow/underflow

Yes

Yes

Yes; channel by channel

Diagnostics indication LED

 

 

 

  • ? Monitoring of the supply voltage (PWR-LED)

Yes; Green LED

Yes; Green LED

Yes; green PWR LED

  • ? Channel status display

Yes; Green LED

Yes; Green LED

Yes; Green LED

  • ? for channel diagnostics

Yes; Red LED

  • ? for module diagnostics

Yes; Green/red LED

Yes; Green/red LED

Yes; green/red DIAG LED

Potential separation

 

 

 

Potential separation channels

 

 

 

  • ? between the channels and backplane bus

Yes

Yes

Yes

Isolation

 

 

 

Isolation tested with

707 V DC

707 V DC

707 V DC (type test)

Ambient conditions

 

 

 

Ambient temperature during operation

 

 

 

  • ? horizontal installation, min.

-40 °C; = Tmin; Startup @ -25 °C

-40 °C; = Tmin; Startup @ -25 °C

-40 °C; = Tmin; Startup @ -25 °C

  • ? horizontal installation, max.

70 °C; = Tmax; > 60 °C max. 1x +/- 20 mA or 4x +/- 10 V permissible

70 °C; = Tmax; > 60 °C max. 1x +/- 20 mA permissible

60 °C

  • ? vertical installation, min.

-40 °C; = Tmin; Startup @ -25 °C

-40 °C; = Tmin; Startup @ -25 °C

-40 °C; = Tmin; Startup @ -25 °C

  • ? vertical installation, max.

50 °C; = Tmax

50 °C; = Tmax

50 °C

Extended ambient conditions

 

 

 

  • ? relative to ambient temperature-atmospheric pressure-installation altitude

Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m)

Relative humidity

 

 

 

  • With condensation, tested in accordance with IEC 60068-2-38, max.

100 %; RH incl. condensation/frost (no commissioning under condensation conditions)

100 %; RH incl. condensation/frost (no commissioning under condensation conditions)

100 %; RH incl. condensation/frost (no commissioning under condensation conditions)

Resistance

 

 

 

  • against biologically active substances / conformity with EN 60721-3-3

Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation!

Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation!

Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation!

  • against chemically active substances / conformity with EN 60721-3-3

Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation!

Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation!

Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation!

  • against mechanically active substances / conformity with EN 60721-3-3

Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!

Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!

Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!

Dimensions

 

 

 

Width

15 mm

15 mm

15 mm

Height

73 mm

73 mm

Depth

58 mm

58 mm

Weights

 

 

 

Weight, approx.

31 g

31 g

31 g


Article number

6AG1134-6HB00-2CA1

6AG1134-6HB00-2DA1

6AG1134-6JF00-2CA1

6AG1134-6JD00-2CA1

SIPLUS ET 200SP AI 2 X U/I 2-, 4-WIRE HF

SIPLUS ET 200SP AI 2 X U/I 2-, 4-WIRE HS

SIPLUS ET 200SP AI 8XRTD/TC 2-WIRE HF

SIPLUS ET 200SP AI 4xRTD/TC HF

General information

 

 

 

 

Product type designation

AI 2xU/I 2-/4-wire HF

AI 8xRTD/TC 2-wire HF

AI 4xRTD/TC 2-/3-/4-wire HF

Product function

 

 

 

 

  • ? I&M data

Yes; I&M0 to I&M3

Yes; I&M0 to I&M3

Yes; I&M0 to I&M3

Yes

  • ? Measuring range scalable

No

No

Engineering with

 

 

 

 

  • ? STEP 7 TIA Portal configurable/integrated as of version

V13

V13 SP1

V13

V11 SP2 with HSP0024 / -

  • ? STEP 7 configurable/integrated as of version

V5.5 SP3 / -

V5.5 SP3 / -

V5.5 / -

V5.5 SP2 with GSD file / -

  • ? PCS 7 configurable/integrated as of version

V8.1 SP1

  • ? PROFIBUS as of GSD version/GSD revision

GSD Revision 5

GSD Revision 5

GSD Revision 5

  • ? PROFINET as of GSD version/GSD revision

GSDML V2.3

GSDML V2.3

GSDML V2.3

Operating mode

 

 

 

 

  • ? Oversampling

No

Yes; 2 channels per module

No

  • ? MSI

No

No

No

CiR – Configuration in RUN

 

 

 

 

Reparameterization possible in RUN

Yes

Yes

Yes

Calibration possible in RUN

Yes

No

Yes

Supply voltage

 

 

 

 

Type of supply voltage

DC

DC

DC

Rated value (DC)

24 V

24 V

24 V

24 V

Reverse polarity protection

Yes

Yes

Yes

Yes

Analog inputs

 

 

 

 

Number of analog inputs

2; Differential inputs

2; Differential inputs

8

4

permissible input voltage for voltage input (destruction limit), max.

30 V

30 V

30 V

30 V

permissible input current for current input (destruction limit), max.

50 mA

50 mA

Constant measurement current for resistance-type transmitter, typ.

2 mA

2 mA

Cycle time (all channels), min.

125 µs

Sum of the basic conversion times and additional processing times (depending on the parameterization of the active channels)

Sum of the basic conversion times and additional processing times (depending on the parameterization of the active channels); for line compensation in case of a three-wire connection, an additional cycle is necessary

Technical unit for temperature measurement adjustable

Yes; °C/°F/K

Yes; °C/°F/K

Analog input with oversampling

Yes

  • ? Values per cycle, max.

16

  • ? Resolution, min.

50 µs

Input ranges (rated values), voltages

 

 

 

 

  • ? 0 to +10 V

Yes; 15 bit

Yes; 15 bit

  • ? 1 V to 5 V

Yes; 15 bit

Yes; 13 bit

  • ? -1 V to +1 V

Yes; 16 bit incl. sign

Yes; 16 bit incl. sign

  • ? -10 V to +10 V

Yes; 16 bit incl. sign

Yes; 16 bit incl. sign

  • ? -250 mV to +250 mV

Yes; 16 bit incl. sign

Yes; 16 bit incl. sign

  • ? -5 V to +5 V

Yes; 16 bit incl. sign

Yes; 15 bit incl. sign

  • ? -50 mV to +50 mV

Yes; 16 bit incl. sign

Yes; 16 bit incl. sign

  • ? -80 mV to +80 mV

Yes; 16 bit incl. sign

Yes; 16 bit incl. sign

Input ranges (rated values), currents

 

 

 

 

  • ? 0 to 20 mA

Yes; 15 bit

Yes; 15 bit

  • ? -20 mA to +20 mA

Yes; 16 bit incl. sign

Yes; 16 bit incl. sign

  • ? 4 mA to 20 mA

Yes; 15 bit

Yes; 14 bit

Input ranges (rated values), thermocouples

 

 

 

 

  • ? Type B

Yes; 16 bit incl. sign

Yes; 16 bit incl. sign

  • ? Type C

Yes; 16 bit incl. sign

Yes; 16 bit incl. sign

  • ? Type E

Yes; 16 bit incl. sign

Yes; 16 bit incl. sign

  • ? Type J

Yes; 16 bit incl. sign

Yes; 16 bit incl. sign

  • ? Type K

Yes; 16 bit incl. sign

Yes; 16 bit incl. sign

  • ? Type L

Yes; 16 bit incl. sign

Yes; 16 bit incl. sign

  • ? Type N

Yes; 16 bit incl. sign

Yes; 16 bit incl. sign

  • ? Type R

Yes; 16 bit incl. sign

Yes; 16 bit incl. sign

  • ? Type S

Yes; 16 bit incl. sign

Yes; 16 bit incl. sign

  • ? Type T

Yes; 16 bit incl. sign

Yes; 16 bit incl. sign

  • ? Type U

Yes; 16 bit incl. sign

Yes; 16 bit incl. sign

  • ? Type TXK/TXK(L) to GOST

Yes; 16 bit incl. sign

Yes; 16 bit incl. sign

Input ranges (rated values), resistance thermometer

 

 

 

 

  • ? Cu 10

Yes; 16 bit incl. sign

  • ? Ni 100

Yes; 16 bit incl. sign

Yes; 16 bit incl. sign

  • ? Ni 1000

Yes; 16 bit incl. sign

Yes; 16 bit incl. sign

  • ? LG-Ni 1000

Yes; 16 bit incl. sign

Yes; 16 bit incl. sign

  • ? Ni 120

Yes; 16 bit incl. sign

Yes; 16 bit incl. sign

  • ? Ni 200

Yes; 16 bit incl. sign

Yes; 16 bit incl. sign

  • ? Ni 500

Yes; 16 bit incl. sign

Yes; 16 bit incl. sign

  • ? Pt 100

Yes; 16 bit incl. sign

Yes; 16 bit incl. sign

  • ? Pt 1000

Yes; 16 bit incl. sign

Yes; 16 bit incl. sign

  • ? Pt 200

Yes; 16 bit incl. sign

Yes; 16 bit incl. sign

  • ? Pt 500

Yes; 16 bit incl. sign

Yes; 16 bit incl. sign

Input ranges (rated values), resistors

 

 

 

 

  • ? 0 to 150 ohms

Yes; 15 bit

Yes; 15 bit

  • ? 0 to 300 ohms

Yes; 15 bit

Yes; 15 bit

  • ? 0 to 600 ohms

Yes; 15 bit

Yes; 15 bit

  • ? 0 to 3000 ohms

Yes; 15 bit

Yes; 15 bit

  • ? 0 to 6000 ohms

Yes; 15 bit

Yes; 15 bit

  • ? PTC

Yes; 15 bit

Yes; 15 bit

Thermocouple (TC)

 

 

 

 

Temperature compensation

 

 

 

 

  • parameterizable

Yes

Yes

Cable length

 

 

 

 

  • ? shielded, max.

1 000 m; 200 m for voltage measurement

1 000 m; 200 m for voltage measurement

200 m; 50 m with thermocouples

200 m; 50 m with thermocouples

Analog value generation for the inputs

 

 

 

 

Integration and conversion time/resolution per channel

 

 

 

 

  • ? Resolution with overrange (bit including sign), max.

16 bit

16 bit

16 bit

16 bit

  • ? Integration time, parameterizable

Yes

Yes

Yes

  • ? Basic conversion time, including integration time (ms)

  • additional processing time for wire-break check

2 ms; In the ranges resistance thermometers, resistors and thermocouples

2 ms; In the ranges resistance thermometers, resistors and thermocouples

  • additional power line wire-break check

2 ms; for 3/4 wire transducer (resistance thermometer and resistor)

  • ? Interference voltage suppression for interference frequency f1 in Hz

16.6 / 50 / 60 / 300 / 600 / 1 200 / 2 400 / 4 800

No

16.6 / 50 / 60 Hz

16.6 / 50 / 60 Hz

  • ? Conversion time (per channel)

10 µs

180 / 60 / 50 ms

180 / 60 / 50 ms

  • ? Basic execution time of the module (all channels released)

1 ms

Smoothing of measured values

 

 

 

 

  • ? Number of smoothing levels

6; none; 2-/4-/8-/16-/32-fold

7; none; 2-/4-/8-/16-/32-/64-fold

4; None; 4/8/16 times

  • ? parameterizable

Yes

Yes

Yes

Yes

Encoder

 

 

 

 

Connection of signal encoders

 

 

 

 

  • ? for voltage measurement

Yes

Yes

Yes

Yes

  • ? for current measurement as 2-wire transducer

Yes

Yes

  • Burden of 2-wire transmitter, max.

650 ?

650 ?

  • ? for current measurement as 4-wire transducer

Yes

Yes

  • ? for resistance measurement with two-wire connection

Yes

Yes

  • ? for resistance measurement with three-wire connection

No

Yes

  • ? for resistance measurement with four-wire connection

No

Yes

Errors/accuracies

 

 

 

 

Basic error limit (operational limit at 25 °C)

 

 

 

 

  • ? Voltage, relative to input range, (+/-)

0.05 %; 0.1 % at SFU 4.8 kHz

0.2 %

0.05 %

0.05 %

  • ? Current, relative to input range, (+/-)

0.05 %; 0.1 % at SFU 4.8 kHz

0.2 %

  • ? Resistance, relative to input range, (+/-)

0.05 %

0.05 %

Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency

 

 

 

 

  • ? Series mode interference (peak value of interference < rated value of input range), min.

70 dB

70 dB

  • ? Common mode voltage, max.

35 V

35 V

10 V

10 V

  • ? Common mode interference, min.

90 dB

90 dB

90 dB

90 dB

Isochronous mode

 

 

 

 

Isochronous operation (application synchronized up to terminal)

Yes

Yes

No

Filtering and processing time (TCI), min.

800 µs

80 µs

Bus cycle time (TDP), min.

1 ms

125 µs

Interrupts/diagnostics/status information

 

 

 

 

Diagnostics function

Yes

Yes

Yes

Alarms

 

 

 

 

  • ? Diagnostic alarm

Yes

Yes

Yes

Yes

  • ? Limit value alarm

Yes; two upper and two lower limit values in each case

Yes; two upper and two lower limit values in each case

Yes; two upper and two lower limit values in each case

Yes; two upper and two lower limit values in each case

Diagnostic messages

 

 

 

 

  • ? Monitoring the supply voltage

Yes

Yes

Yes

  • ? Wire-break

Yes; Measuring range 4 to 20 mA only

Yes; channel-by-channel, at 4 to 20 mA only

Yes; channel by channel

Yes

  • ? Short-circuit

Yes; For 1 to 5 V or for current measuring ranges short-circuit in encoder supply

Yes; channel-by-channel, at 1 to 5 V or for current measuring ranges short-circuit in encoder supply

  • ? Group error

Yes

Yes

Yes

  • ? Overflow/underflow

Yes

Yes

Yes; channel by channel

Yes

Diagnostics indication LED

 

 

 

 

  • ? Monitoring of the supply voltage (PWR-LED)

Yes; green PWR LED

Yes; green PWR LED

Yes; green PWR LED

Yes; Green LED

  • ? Channel status display

Yes; Green LED

Yes; Green LED

Yes; Green LED

Yes; Green LED

  • ? for channel diagnostics

Yes; Red LED

Yes; Red LED

Yes; Red LED

Yes; Red LED

  • ? for module diagnostics

Yes; green/red DIAG LED

Yes; green/red DIAG LED

Yes; green/red DIAG LED

Yes; Green/red LED

Potential separation

 

 

 

 

Potential separation channels

 

 

 

 

  • ? between the channels and backplane bus

Yes

Yes

Yes

Yes

Isolation

 

 

 

 

Isolation tested with

707 V DC (type test)

707 V DC (type test)

707 V DC (type test)

707 V DC

Ambient conditions

 

 

 

 

Ambient temperature during operation

 

 

 

 

  • ? horizontal installation, min.

-40 °C; = Tmin; Startup @ -25 °C

-40 °C; = Tmin; Startup @ -25 °C

-40 °C; = Tmin; Startup @ -25 °C

-40 °C; = Tmin; Startup @ -25 °C

  • ? horizontal installation, max.

60 °C; = Tmax

60 °C; = Tmax

60 °C

60 °C; = Tmax

  • ? vertical installation, min.

-40 °C; = Tmin; Startup @ -25 °C

-40 °C; = Tmin; Startup @ -25 °C

  • ? vertical installation, max.

50 °C

50 °C; = Tmax

Extended ambient conditions

 

 

 

 

  • ? relative to ambient temperature-atmospheric pressure-installation altitude

Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m)

Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m)

Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m)

Relative humidity

 

 

 

 

  • With condensation, tested in accordance with IEC 60068-2-38, max.

100 %; RH incl. condensation / frost (no commissioning in bedewed state), horizontal installation

100 %; RH incl. condensation / frost (no commissioning in bedewed state), horizontal installation

100 %; RH incl. condensation/frost (no commissioning under condensation conditions)

100 %; RH incl. condensation/frost (no commissioning under condensation conditions)

Resistance

 

 

 

 

  • against biologically active substances / conformity with EN 60721-3-3

Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation!

Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation!

Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation!

Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation!

  • against chemically active substances / conformity with EN 60721-3-3

Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation!

Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation!

Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation!

Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation!

  • against mechanically active substances / conformity with EN 60721-3-3

Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!

Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!

Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!

Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!

Dimensions

 

 

 

 

Width

15 mm

15 mm

15 mm

15 mm

Height

73 mm

Depth

58 mm

Weights

 

 

 

 

Weight, approx.

32 g

32 g

32 g

30 g


Article number

6AG1134-6PA00-7BD0

SIPLUS ET 200SP AI Energy Meter

General information

 

Product type designation

AI energy meter 400VAC ST

Product function

 

  • ? Voltage measurement

Yes

  • ? Current measurement

Yes

  • ? Energy measurement

Yes

  • ? Frequency measurement

Yes

  • ? Active power measurement

Yes

  • ? Reactive power measurement

Yes

  • ? I&M data

Yes

  • ? Isochronous mode

No

Operating mode

 

  • ? cyclic measurement

Yes

  • ? acyclic measurement

Yes

Installation type/mounting

 

Mounting position

Horizontal

Supply voltage

 

Design of the power supply

Supply via voltage measurement channel L1

Type of supply voltage

100 - 240 V AC

permissible range, lower limit (AC)

90 V

permissible range, upper limit (AC)

264 V

relative symmetrical tolerance of the supply voltage

10 %

Line frequency

 

  • ? permissible range, lower limit

47 Hz

  • ? permissible range, upper limit

63 Hz

Power

 

Power consumption without expansion module, typ.

0.6 V·A

Address area

 

Address space per module

 

  • ? Address space per module, max.

44 byte; 32 byte input / 12 byte output

Analog inputs

 

Cycle time (all channels), typ.

50 ms

Analog value generation for the inputs

 

Integration and conversion time/resolution per channel

 

  • ? Resolution with overrange (bit including sign), max.

24 bit; Sigma-delta converter, 1.024 MHz

Interrupts/diagnostics/status information

 

Alarms

 

  • ? Diagnostic alarm

Yes

  • ? Limit value alarm

No

Diagnostics indication LED

 

  • ? Monitoring of the supply voltage (PWR-LED)

Yes

  • ? Channel status display

Yes

  • ? for channel diagnostics

Yes

  • ? for module diagnostics

Yes

Integrated Functions

 

Measuring functions

 

  • ? Measuring procedure for voltage measurement

TRMS

  • ? Measuring procedure for current measurement

TRMS

  • ? Type of measured value acquisition

seamless

  • ? Curve shape of voltage

Sinusoidal or distorted

  • ? Buffering of measured variables

No

  • ? Parameter length

44 byte

Operating mode for measured value acquisition

 

  • automatic detection of line frequency

No; Parameterizable

  • Fixation to 50 Hz

No; Default setting

  • Fixation to 60 Hz

No

Measuring range

 

  • Frequency measurement, min.

45 Hz

  • Frequency measurement, max.

65 Hz

Measuring inputs for voltage

 

  • Measurable line voltage between phase and neutral conductor

230 V

  • Measurable line voltage between the line conductors

400 V

  • Measurable line voltage between phase and neutral conductor, min.

90 V

  • Measurable line voltage between phase and neutral conductor, max.

264 V

  • Measurable line voltage between the line conductors, min.

155 V

  • Measurable line voltage between the line conductors, max.

460 V

  • Measurement category for voltage measurement

CAT III acc. to IEC 61010 Part 1

  • Power consumption per phase

20 mW

Measuring inputs for current

 

  • measurable relative current (AC), min.

5 %; Relative to the secondary rated current; 1 A, 5 A

  • measurable relative current (AC), max.

100 %; Relative to the secondary rated current; 1 A, 5 A

  • Continuous current with AC, maximum permissible

5 A

  • Apparent power consumption per phase for measuring range 5 A

0.6 V·A

  • Rated value short-time withstand current restricted to 1 s

100 A

  • Zero point suppression

50 mA

  • Surge strength

10 A; for 1 minute

Error limits

 

  • Reference condition for measurement accuracy

Symmetric load, rated current: 20-100%, 50 Hz; active power: LF = 1, reactive power: LF = 0

  • for measured variable voltage

±0.5%

  • for measured variable current

±0.5%

  • for measured variable power

±0.5%

  • for measured variable active power

±0.5%

  • for measured variable reactive power

±0.5%

  • for measured variable total active energy

Class 1 acc. to IEC 62053-21:2003

  • for measured variable total reactive energy

Class 2 acc. to IEC 62053-23:2003

Ambient conditions

 

Ambient temperature during operation

 

  • ? horizontal installation, min.

-40 °C; = Tmin; Startup @ -25 °C

  • ? horizontal installation, max.

70 °C; = Tmax; > +60 °C max. permissible current 1 A per phase

  • ? vertical installation, min.

-40 °C; = Tmin; Startup @ -25 °C

  • ? vertical installation, max.

50 °C; = Tmax

Extended ambient conditions

 

  • ? relative to ambient temperature-atmospheric pressure-installation altitude

Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m)

Relative humidity

 

  • With condensation, tested in accordance with IEC 60068-2-38, max.

100 %; RH incl. condensation/frost (no commissioning under condensation conditions)

Resistance

 

  • against biologically active substances / conformity with EN 60721-3-3

Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation!

  • against chemically active substances / conformity with EN 60721-3-3

Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation!

  • against mechanically active substances / conformity with EN 60721-3-3

Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!

Dimensions

 

Width

20 mm

Weights

 

Weight (without packaging)

45 g

Data for selecting a current transformer

 

  • ? Burden power current transformer x/1A, min.

1.25 V·A

  • ? Burden power current transformer x/5A, min.

1.5 V·A

  • ? Cable length (terminal-transformer) dependent on Zn and Imax

200 m


















skener.ru

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Àðìàòóðà DENDOR

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Äàò÷èêè è èçìåðèòåëè

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Ðåãóëÿòîðû è ðåãèñòðàòîðû

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Ïíåâìàòè÷åñêîå îáîðóäîâàíèå

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Êðàíû è Êëàïàíû

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Èçìåðèòåëüíûå ïðèáîðû

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Ñèñòåìû áåñïðîâîäíîãî óïðàâëåíèÿ «óìíûé äîì»

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Áåñêîíòàêòíûå âûêëþ÷àòåëè Êîíå÷íûå âûêëþ÷àòåëè Îïòè÷åñêèå äàò÷èêè Ýíêîäåðû

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
SKW-FS - Óñòàíîâêà óìÿã÷åíèÿ

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
SKW-FK - Óñòàíîâêà îáåçæåëåçèâàíèÿ
Êàòàëîã îáîðóäîâàíèÿ 2017
Siemens Industry Catalog Drive Technology Automation Technology Automation Systems Operator control and monitoring systems SIMATIC HMI Identification systems Industrial Communication Industrial Controls Manufacturing Execution Systems (MES) SIMATIC IT PC-based Automation Process control systems Process instrumentation Process analytics SITOP power supplies Products for specific requirements Automation technology for extreme conditions SIMATIC industrial automation systems Controllers SIPLUS IO systems SIPLUS ET 200 systems for the control cabinet ET 200SP SIPLUS interface modules SIPLUS extreme RAIL interface modules SIPLUS I/O modules SIPLUS digital inputs SIPLUS digital outputs SIPLUS analog inputs SIPLUS analog outputs SIPLUS technology modules SIPLUS communication SIPLUS failsafe I/O modules SIPLUS extreme RAIL digital inputs SIPLUS extreme RAIL digital outputs SIPLUS extreme RAIL analog inputs SIPLUS extreme RAIL analog outputs SIPLUS extreme RAIL communication SIPLUS BaseUnits SIPLUS BusAdapters SIPLUS extreme RAIL BaseUnits SIPLUS extreme RAIL BusAdapter ET 200S ET 200MP ET 200M SIPLUS PROFIBUS components for ET 200 SIMOTION Motion Control System Process control systems Operator control and monitoring systems Industrial communication Industrial controls Power supplies SIPLUS add-ons Telecontrol Systems for Comprehensive Applications IO systems for heating elements Automatic door controls Condition Monitoring Systems Time synchronization Energy Building Technologies Low-Voltage Controls and Distribution Safety Systems - Safety Integrated Market-specific solutions Industry Services ... and everything else you need




  © ÎÎÎ "ÑÊ ÝÍÅÐÃÎ" 2007-2022
  (4872) 700-366  skenergo@mail.ru
ßíäåêñ.Ìåòðèêà