General information | |
Weight | Approx. 5.5 kg (standard version) |
Measuring ranges | |
Number of measuring ranges | Max. 4; parameters can be assigned freely |
Parameters can be assigned in the measuring ranges | |
- Smallest possible measuring spans
| 0.5%, 1%, 2% or 5% O2 |
- Largest possible measuring span
| 100% O2 |
Gas inlet conditions | |
Sample gas pressure | |
- Standard devices with hoses
| 500 … 1 500 hPa (abs.) |
- Standard devices with hoses and ext. RG pump
| Atmospheric pressure ± 50 hPa |
- Standard devices with pipes
| 500 … 3 000 hPa (abs.); briefly < 5 000 hPa (abs.) |
| |
- For non-combustible gases
| 500 … 2 500 hPa (abs.) |
- For combustible gases up to gas mixtures which are occasionally explosive
| 800 … 1 100 hPa (abs.) |
Reference gas pressure | |
| 2000 hPA above sample gas pressure (within permitted reference gas pressure range 2500 to 5000 hPa, abs.) |
- Low-pressure connection with external reference gas pump
| 100 hPa above sample gas pressure |
Pressure drop between sample gas inlet and sample gas outlet | < 100 hPa at 1 l/min |
Sample gas flow | 18 … 60 l/h (0.3 … 1 l/min) |
Sample gas temperature | 0 … 60 °C |
Sample gas humidity (rel. humidity) | < 90% (condensation inside the gas path is to be avoided) |
Sample chamber temperature | |
Standard version | Approx. 72 °C |
Time response | |
Warm-up period at room temperature | < 2 h |
Response characteristics | |
- Display delay T90 with an electronic damping setting of 0 s and a sample gas flow of 1 Nl/min.
| ? 1.9 s; ? 2.4 s (field module including flame arrestor) |
| ? 1.1 s; < 1.6 s (field module) |
Measuring response | |
Output signal fluctuation with static damping constant of 0 s and dynamic noise suppression of 5% / 10 s | ? ±0.5% of smallest measuring span (noise bandwidth corresponds to 1% = 6? value or 0.333% = 2? value), with vibration compensation activated: < 1.5 times the value |
Detection limit | ? 1% of smallest measuring span according to nameplate (with vibration compensation activated: < 1.5 times the value) |
Measured-value drift | |
| ? ±0.5% of the smallest span/month or ? ±50 vpm O2/month, whichever is greater |
| ? ±0.5% of the current measuring span/month or ? ±50 vpm O2/month, whichever is greater |
Repeatability | |
| ? ±0.5% of the smallest measuring span/month or ? ±50 vpm O2/month, whichever is greater |
| d? ±0.5% of the current measuring span/month or ? ±50 vpm O2, whichever is greater |
Linearity error with dry ambient air1) | < 0.1% |
Influencing variables | |
Ambient temperature | |
| ? 0.5% of the smallest measuring span / 10 K or ? 50 vpm O2/10 K, whichever is greater |
- Deviation of the span gas
| ? 0.5% of the current measuring span / 10 K or ? 50 vpm O2/10 K, whichever is greater |
Sample gas pressure | |
| ? 0.2% of the smallest measuring span / 1% pressure variation or ? 50 vpm O2/1% pressure variation, whichever is greater |
- Deviation of the span gas
| ? 0.2% of the current measuring span / 1% pressure variation or ? 50 vpm O2/1% pressure variation, whichever is greater |
Sample gas flow | |
| ? 1% of smallest measuring span per 0.1 l/min change in flow or ? 50 vpm O2 per 0.1 l/min change in flow within the permissible flow range (0.3 to 1 l/min), whichever is greater |
- Deviation of the span gas
| ? 1% of current measuring span per 0.1 l/min change in flow or ? 50 vpm O2 per 0.1 l/min change in flow within the permissible flow range (0.3 to 1 l/min), whichever is greater |
Accompanying gases | Zero point deviation (cross-sensitivity) in accordance with Table A.1 of EN 61207-3 |
Supply voltage | < 0.1% of the current measuring span (within the nominal range of use) |
Electrical inputs and outputs | |
Analog and digital interfaces | See base unit |
Gas connections | |
Connection fittings | Pipe connection with 6 mm outer diameter |
Climatic conditions | |
Storage and transport | -30 to 70 °C |
Permissible ambient temperature (during operation in base unit)2) | 0 to 50 °C |
Relative humidity (RH) during storage, transport or operation | < 90% (condensation from the installed components is to be avoided) |
Materials of wetted parts | |
Sample chamber | Stainless steel: - Plates: Mat. No. 1.4571 (X6CrNiMoTi 17-12-2)
- Screw-in glands: Mat. No. 1.4404 (X2CrNiMo17-12-2)
|
Internal gas path | |
| FPM (e.g. Viton), gas connections of stainless steel material no. 14404 (X2CrNiMo 17-12-2) |
| Stainless steel: - Pipes: Mat. No. 1.4571 (X6CrNiMoTi 17-12-2)
- Gas connections: Mat. No. 1.4404 (X2CrNiMo 17-12-2)
|
Sealing material | FPM (e.g. Viton) or FFKM (e.g. Kalrez 6375) |
Special applications | |
Gas path | |
| Materials adapted to the application |