Product characteristic | Flexible product program | Flexible product program |
Nominal size | DN 15 … DN 2000 (?" … 78") | DN 15 … DN 300 (?" … 12") |
Measuring principle | Electromagnetic induction | Electromagnetic induction |
Excitation frequency (Mains supply: 50 Hz/60 Hz) | - DN 15 … 65 (?" … 2?"): 12.5 Hz/15 Hz
| - DN 15 … 65 (?" … 2?"): 12.5 Hz/15 Hz
|
- DN 80 … 150 (3" … 6"): 6.25 Hz/7.5 Hz
| - DN 80 … 150 (3" … 6"): 6.25 Hz/7.5 Hz
|
- DN 200 … 1200 (8" … 48"): 3.125 Hz/3.75 Hz
| - DN 200 … 300 (8" … 12"): 3.125 Hz/3.75 Hz
|
- DN 1400 … 2000 (54" … 78"): 1.5625 Hz/1.875 Hz
| |
Process connection | | |
Flanges | EN 1092-1, raised face1) (EN 1092-1, DIN 2501 & BS 4504 have the same mating dimensions) | EN 1092-1, raised face (EN 1092-1, DIN 2501 & BS 4504 have the same mating dimensions) |
- DN 65 … 2000 (2?" … 78"): PN 6 (87 psi)
| - DN 15 … 300 (?" … 12"): PN 40 (580 psi)
|
- DN 200 … 2000 (8" … 78"): PN 10 (145 psi)
| - DN 65 … 300 (2?" … 12"): PN 16 (232 psi)
|
- DN 65 … 2000 (2?" … 78"): PN 16 (232 psi)
| - DN 200 … 300 (8" … 12"): PN 10 (145 psi)
|
- DN 200 … 600 (8" … 24"): PN 25 (362 psi)
| - DN 200 … 300 (8" … 12"): PN 25 (362 psi)
|
- DN 15 … 600 (?" … 24”): PN 40 (580 psi)
|
- DN 50 … 300 (2" … 12"): PN 63 (913 psi)
|
- DN 25 … 300 (1" … 12"): PN 100 (1450 psi)
|
ANSI B16.5 (~BS 1560), raised face: | ANSI B16.5 (~BS 1560), raised face: |
- ?" … 24": Class 150 (20 bar (290 psi))
| - ?" … 12": Class 150 (20 bar (290 psi))
|
- ?" … 24": Class 300 (50 bar (725 psi))
| - ?" … 12": Class 300 (50 bar (725 psi))
|
AWWA C-207, flat face 28" … 78": Class D (10 bar) | |
AS 2129, raised face ?" … 48": Table E | AS 2129, raised face ?" … 12": Table E |
AS 4087, raised face: |
- PN 16 (DN 50 … 1200, 16 bar (232 psi))
|
- PN 21 (DN 50 … 600, 21 bar (304 psi))
|
- PN 35 (DN 50 … 600, 35 bar (508 psi))
|
JIS B 2220:2004 |
|
|
Other flanges and pressure ratings on request | Other flanges and pressure ratings on request |
Rated operation conditions | | |
Ambient temperature (conditions also dependent on liner characteristiques) | | |
| -40 … +100 °C (-40 … +212 °F) | -40 … +100 °C (-40 … +212 °F) |
| -20 … +60 °C (-4 … +140 °F) | For medium temperature up to 150 °C (302 °F): -20 … +60 °C (-4 … +140 °F) |
For medium temperature 150 … 180 °C (302 … 356 °F): -20 … +50 °C (-4 … +122 °F) |
| | |
| -20 … +60 °C (-4 … +140 °F) | -20 … +60 °C (-4 … +140 °F) |
| -20 … +60 °C (-4 … +140 °F) | -20 … +60 °C (-4 … +140 °F) |
| -20 … +60 °C (-4 … +140 °F) | -20 … +60 °C (-4 … +140 °F) |
Operating pressure [abs. bar] (maximum operating pressure decreases with increasing operating temperature and with stainless steel flanges) | - Softrubber 0.01 … 100 bar (0.15 … 1450 psi)
| |
- EPDM 0.01 … 40 bar (0.15 … 580 psi)
| |
- Linatex 0.01 … 40 bar (0.15 ... 580 psi)
| |
- Ebonite 0.01 … 100 bar (0.15 … 1450 psi)
| |
| |
- DN ? 300 (? 12"): 0.3 … 50 bar (4 … 725 psi)
| - DN 15 … 300 (?" … 12"): 0.3/0.6 … 50 bar (4/8 … 725 psi) (180 °C (356 °F).
Factory mounted grounding rings type E in stainless steel and stainless steel terminal box. Can nly be used with remote transmitter.
|
- 350 ? DN ? 600 (14"? DN ? 24"): 0.3 … 40 bar (4 … 580 psi)
|
| |
- DN 15 … 150 (?" … 6"): Vacuum 0.02 … 50 bar (0.29 … 725 psi)
| - DN 15 … 150 (?" … 6"): Vacuum 0.02 … 50 bar (0.29 … 725 psi)
|
Enclosure rating | IP67 to EN 60529/NEMA 6P/10, 1 mH2O for 30 min | IP67 to EN 60529/NEMA 4X/6, 1 mH2O for 30 min |
| Option: IP68 to EN 60529/NEMA 6P,10 mH2O cont. | Option: IP68 to EN 60529/NEMA 6P,10 mH2O cont. |
Pressure drop at 3 m/s | As straight pipe |
Test pressure | 1.5 x PN (where applicable) |
Mechanical load (vibration) | 18 … 1000 Hz random in x, y, z, directions for 2 hours according to EN 60068-2-36 | 18 … 1000 Hz random in x, y, z, directions for 2 hours according to EN 60068-2-36 |
Sensor: 3.17 g RMS | Sensor: 3.17 g RMS |
Sensor with compact MAG 5000/6000 mounted transmitter: 3.17 g RMS | Sensor with compact MAG 5000/6000 mounted transmitter: 3.17 g RMS |
Sensor with compact MAG 6000 I/6000 I Ex mounted transmitter: 1.14 g RMS | Sensor with compact MAG 6000 I/6000 I Ex mounted transmitter: 1.14 g RMS |
Temperature of medium | - Soft rubber 0 … +70 °C (32 … 158 °F)
| - PTFE -20 … +130 °C (-4 … +266 °F)
|
- EPDM -10 … +70 °C (14 … 158 °F)
| - PTFE -20 … +180 °C (-4 … +356 °F) Factory mounted grounding rings type E in stainless steel and stainless steel terminal box. Can only be used with remote transmitter.
|
- Linatex (rubber) -40 … +70 °C (-40 … +158 °F) (for temperatures below -20 °C (-4 °F) AISI 304 or 316 flanges must be used)
| - PFA -20 … +150 °C (-4 … +300 °F)
|
- Ebonite 0 … 95 °C (32 … 203 °F)
| |
- PTFE -20 … +100 °C (-4 … +212 °F)
| |
- PFA -20 … +100 °C (-4 … +212 °F)
| |
EMC | 2014/30/EU | 2014/30/EU |
Design | | |
Weight | See dimensional drawings |
Flange and housing material | Carbon steel ASTM A 105, with corrosion resistant coating (Corrosivity category C4M, according to ISO 12944-2) | Carbon steel ASTM A 105, with corrosion resistant coating (Corrosivity category C4M, according to ISO 12944-2) |
or | or |
Stainless steel AISI 304/1.4301flanges and carbon steel housing, with corrosion resistant coating (Corrosivity category C4M, according to ISO 12944-2) | Stainless steel AISI 304/1.4301 flanges and carbon steel housing, with corrosion resistant coating (Corrosivity category C4M, according to ISO 12944-2) |
or | or |
Stainless steel AISI 316L/1.4404 flanges and housing, polished | Stainless steel AISI 316L/1.4404 flanges and housing, polished |
Electrode material | - Stainless steel AISI 316Ti/1.4571
| - Stainless steel AISI 316Ti/1.4571
|
- Hastelloy C276/2.4819 (PFA: Hastelloy C22/2.4602)
| - Hastelloy C276/2.4819 (PFA: Hastelloy C22/2.4602)
|
| |
| |
| |
Grounding electrode material | - Soft rubber, EPDM, Linatex, Ebonite:
available with grounding electrodes in stainless steel AISI 316Ti/1.4571 or Hastelloy
| |
- PTFE: no grounding electrodes
| - PTFE: no grounding electrodes
|
- PFA: optional in Hastelloy, Tantalum or Platinum
| - PFA: optional in Hastelloy, Tantalum or Platinum
|
Terminal box (remote version only) | - Standard fibre glass reinforced polyamide
| - Standard fibre glass reinforced polyamide (max. 150 °C (302 °F))
|
- Option Stainless steel AISI 316/1.4436
| - Stainless steel AISI 316/1.4436
|
- Ex Stainless steel AISI 316/1.4436
| - Ex Stainless steel AISI 316/1.4436
|
Cable entries | - Remote installation 2 x M20 or 2 x ?" NPT
| - Remote installation 2 x M20 or 2 x ?" NPT
|
| |
- MAG 5000/MAG 6000: 4 x M20 or 4 x ?" NPT
| |
- MAG 6000 I: 2 x M25 or 2 x ?" NPT (for supply/output)
| |
- MAG 6000 I Ex: 2 x M25 or 2 x ?" NPT (for supply/output)
| |
Certificates and approvals | | |
Calibration | | |
- Standard production calibration
| Zero-point, 2 x 25 % and 2 x 90 % (default) | Zero-point, 2 x 25 % and 2 x 90 % |
| 5-point calibration: 20%, 40%, 60%, 80%, 100% of factory Qmax 10-point calibration: ascending and descending at 20%, 40%, 60%, 80%, 100% of factory Qmax Matched pair calibration: default, 5-point or 10-point | |
Hazardous areas2) | | |
- Ex-sensor in compact or remote version with MAG 6000 I Ex
| - ATEX, FM, CSA, IECEx, EAC Ex, NEPSI
- Zone 1 Ex d e ia IIC T6 Gb4)
- Zone 1 Ex e ia IIC T6 Gb5)
- XP IS Class I Div. 1 Groups A, B, C, D6)
- DIP Class II+III Div. 1 Groups E, F, G6)
| - ATEX, FM, CSA, IECEx, EAC Ex, NEPSI
- Zone 1 Ex d e ia IIC T6 Gb4)
- Zone 1 Ex e ia IIC T6 Gb5)
- XP IS Class I Div. 1 Groups A, B, C, D6)
- DIP Class II+III Div. 1 Groups E, F, G6)
|
- Standard sensor with/without MAG 5000/6000/6000 I
| - NI Class I Div. 2 Groups A, B, C, D
- NI Class I Zone 2 Groups IIC
| - NI Class I Div. 2 Groups A, B, C, D
- NI Class I Zone 2 Groups IIC
|
Drinking water | EPDM liner: - WRAS (WRc, BS690 cold water, GB)
- NSF/ANSI Standard 617) (Cold water, US)
- ACS listed (F)
- DVGW W270 (D)
- Belgaqua (B)
- MCERTS (GB) (EPDM or PTFE lining with AISI 316 or Hastelloy electrodes)
| |
Pressure equipment | - PED conforming: All EN1092-1 flanges
| - PED conforming: All EN1092-1 flanges
|
Others | - EAC (Russia, Belarus, Kzakhstan)
- KCC (South Korea)
- CMC/CPA (china)
| - EAC (Russia, Belarus, Kzakhstan)
- KCC (South Korea)
- CMC/CPA (china)
|