Siemens
ÑÐÅÄÑÒÂÀ ÏÐÎÌÛØËÅÍÍÎÉ ÀÂÒÎÌÀÒÈÇÀÖÈÈ
îôèöèàëüíûé ïàðòíåð Ñèìåíñ
Êàòàëîã ÑÀ01 2017
àðõèâíûé
(4872) 700-366
skenergo@mail.ru

Power Modules

 Product name

Power Modules in blocksize format

 

6SL3210-...

Line voltage

Up to 2000 m (6562 ft) above sea level

200 V ... 240 V 1 AC ±10 %
(-15 % < 1 min) or

380 ... 480 V 3 AC ±10 %
(-15 % < 1 min)

Line frequency

47 … 63 Hz

Line power factor

With rated power

 

  • Fundamental component (cos ?1)

> 0.96

  • Total (?)

 

  • 200 … 240 V 1 AC

0.45 … 0.7

  • 380 … 480 V 3 AC

0.65 … 0.95

Overvoltage category

In accordance with EN 60664-1

Class III

Precharging frequency

Of the DC link, max.

1? every 30 s

DC link voltage, approx.

1.35 ? line voltage

Output frequency

0 … 650 Hz 1)2)

Electronic power supply

24 V DC -15 %/+20 %

Radio interference suppression

 

  • Standard

No radio interference suppression

  • With integrated line filter

Category C2 according to EN 61800?3

Cooling method

Increased air cooling by means of built-in fan

Permissible ambient or coolant temperature (air)

In operation for line-side components, Power Modules

0 … 40 °C (32  … 104 °F) without derating,
> 40 … 55 °C (104  … 131 °F), see derating characteristics

Installation altitude

Up to 1000 m (3281 ft) above sea level without derating,
> 1000 ... 4000 m (3281 ... 13124 ft) above sea level, see derating characteristics

Declarations of conformity

CE (Low Voltage and EMC Directives)

Approvals, according to

cULus

Safety Integrated

Safety Integrity Level 2 (SIL 2) according to IEC 61508,
Control category 3 according to EN 954-1



1) Note the correlation between max. output frequency, pulse frequency and current derating. For further information see System Descripition.

2) The output frequency is currently limited to 550 Hz. The specified values apply to systems with license for high output frequency. Fore more information, refer to section Control Units and http://support.automation.siemens.com/WW/view/en/104020669

Line voltage 200 … 240 V 1 AC

PM340 Power Module in blocksize format

 

6SL3210-...

1SB11?0...

1SB12?3...

1SB14?0...

Output current

 

 

 

 

  • Rated current Irated

A

0.9

2.3

3.9

  • Base-load current IH

A

0.8

2.0

3.4

  • For S6 duty (40%) IS6

A

1.4

3.3

5.5

  • Imax

A

2.0

4.6

7.8

Type rating 1)

Based on Irated

kW (HP)

0.12 (0.2)

0.37 (0.5)

0.75 (0.75)

Rated pulse frequency

kHz

4

4

4

Power loss

kW

0.06

0.075

0.11

Cooling air requirement

m3/s (ft3/s)

0.005 (0.2)

0.005 (0.2)

0.005 (0.2)

Sound pressure level LpA (1 m)

dB

< 45

< 45

< 45

24 V DC power supply

For Control Unit

A

1.0

1.0

1.0

Rated input current 2)

With/without line reactor

A

1.4/2.2

4/6

6.5/10

Resistance value

External braking resistor

?

? 180

? 180

? 180

Cable length

To braking resistor, max.

m (ft)

15 (49)

15 (49)

15 (49)

Line connection

L, N

 

Screw-type terminals

Screw-type terminals

Screw-type terminals

  • Conductor cross-section

mm2

1.0 … 2.5

1.0 … 2.5

1.0 … 2.5

Motor connection

U2, V2, W2

 

Screw-type terminals

Screw-type terminals

Screw-type terminals

  • Conductor cross-section

mm2

1.0 … 2.5

1.0 … 2.5

1.0 … 2.5

DC link connection,
connection for braking resistor

DCP/R1, DCN, R2

 

Screw-type terminals

Screw-type terminals

Screw-type terminals

  • Conductor cross-section

mm2

1.0 … 2.5

1.0 … 2.5

1.0 … 2.5

PE connection

 

M4 screw

M4 screw

M4 screw

Motor cable length 3), max.

Without external options

 

 

 

 

  • Shielded

m (ft)

50 (164)

50 (164)

50 (164)

  • Unshielded

m (ft)

75 (246)

75 (246)

75 (246)

Degree of protection

 

IP20

IP20

IP20

Dimensions

 

 

 

 

  • Width

mm (in)

73 (2.87)

73 (2.87)

73 (2.87)

  • Height

mm (in)

173 (6.81)

173 (6.81)

173 (6.81)

  • Depth

 

 

 

 

  • PM340

mm (in)

145 (5.71)

145 (5.71)

145 (5.71)

  • PM340 with CU310

mm (in)

234.6 (9.24)

234.6 (9.24)

234.6 (9.24)

  • PM340 with CUA31

mm (in)

175.3 (6.90)

175.3 (6.90)

175.3 (6.90)

Frame size

 

FSA

FSA

FSA

Net weight

kg (lb)

1.2 (2.65)

1.3 (3)

1.3 (3)



1) Nominal HP based on asynchronous motors and 460 V AC. For specific sizing select drive based on motor nameplate current and overload.

2) The input current depends on the motor load and line impedance. The input currents apply for rated power loading (based on Irated) for a line impedance corresponding to uk = 1 %.

3) Max. motor cable length 15 m (49 ft) (shielded) for PM340 Power Modules with integrated line filter to maintain the limit values of EN 61800-3 Category C2.

 

Line voltage 380 … 480 V 3 AC

PM340 Power Module in blocksize format

 

6SL3210-...

1SE11?3UA0

1SE11?7UA0

1SE12?2UA0

1SE13?1UA0

1SE14?1UA0

Output current

 

 

 

 

 

 

  • Rated current Irated

A

1.3

1.7

2.2

3.1

4.1

  • Base-load current IH

A

1.1

1.5

1.9

2.7

3.6

  • For S6 duty (40%) IS6

A

1.3

2.0

2.5

3.5

4.5

  • Imax

A

2.6

3.4

4.4

6.2

8.2

Type rating 1)

 

 

 

 

 

 

  • Based on Irated

kW (HP)

0.37 (0.5)

0.55 (0.75)

0.75 (1)

1.1 (1.5)

1.5 (2)

  • Based on IH

kW (HP)

0.37 (0.5)

0.55 (0.5)

0.75 (0.75)

1.1 (1)

1.5 (2)

Rated pulse frequency

kHz

4

4

4

4

4

Power loss

kW

0.10

0.10

0.10

0.11

0.11

Cooling air requirement

m3/s (ft3/s)

0.005 (0.2)

0.005 (0.2)

0.005 (0.2)

0.005 (0.2)

0.005 (0.2)

Sound pressure level LpA (1 m)

dB

< 45

< 45

< 45

< 45

< 45

24 V DC power supply

For Control Unit

A

1.0

1.0

1.0

1.0

1.0

Rated input current 2)

With/without line reactor

A

1.3/1.7

1.7/2.2

2.2/2.6

3.1/3.9

4.1/4.8

Resistance value

External braking resistor

?

? 390

? 390

? 390

? 390

? 390

Cable length

To braking resistor, max.

m (ft)

15 (49)

15 (49)

15 (49)

15 (49)

15 (49)

Line connection

U1/L1, V1/L2, W1/L3

 

Screw-type terminals

Screw-type terminals

Screw-type terminals

Screw-type terminals

Screw-type terminals

  • Conductor cross-section

mm2

1.0 … 2.5

1.0 … 2.5

1.0 … 2.5

1.0 … 2.5

1.0 … 2.5

Motor connection

U2, V2, W2

 

Screw-type terminals

Screw-type terminals

Screw-type terminals

Screw-type terminals

Screw-type terminals

  • Conductor cross-section

mm2

1.0 … 2.5

1.0 … 2.5

1.0 … 2.5

1.0 … 2.5

1.0 … 2.5

DC link connection,
connection for the braking resistor

DCP/R1, DCN, R2

 

Screw-type terminals

Screw-type terminals

Screw-type terminals

Screw-type terminals

Screw-type terminals

  • Conductor cross-section

mm2

1.0 … 2.5

1.0 … 2.5

1.0 … 2.5

1.0 … 2.5

1.0 … 2.5

PE connection

 

M4 screw

M4 screw

M4 screw

M4 screw

M4 screw

Motor cable length 3), max.

 

 

 

 

 

 

  • Shielded

m (ft)

50 (164)

50 (164)

50 (164)

50 (164)

50 (164)

  • Unshielded

m (ft)

75 (246)

75 (246)

75 (246)

75 (246)

75 (246)

Degree of protection

 

IP20

IP20

IP20

IP20

IP20

Dimensions

 

 

 

 

 

 

  • Width

mm (in)

73 (2.87)

73 (2.87)

73 (2.87)

73 (2.87)

73 (2.87)

  • Height

mm (in)

173 (6.81)

173 (6.81)

173 (6.81)

173 (6.81)

173 (6.81)

  • Depth

 

 

 

 

 

 

  • PM340

mm (in)

145 (5.71)

145 (5.71)

145 (5.71)

145 (5.71)

145 (5.71)

  • PM340 with CU310

mm (in)

234.6 (9.24)

234.6 (9.24)

234.6 (9.24)

234.6 (9.24)

234.6 (9.24)

  • PM340 with CUA31

mm (in)

175.3 (6.90)

175.3 (6.90)

175.3 (6.90)

175.3 (6.90)

175.3 (6.90)

Frame size

 

FSA

FSA

FSA

FSA

FSA

Net weight

kg (lb)

1.2 (3)

1.2 (3)

1.2 (3)

1.2 (3)

1.2 (3)



1) Nominal HP based on asynchronous motors and 460 V AC. For specific sizing select drive based on motor nameplate current and overload.

2) The input current depends on the motor load and line impedance. The input currents apply for rated power loading (based on Irated) for a line impedance corresponding to uk = 1 %.

3) Max. motor cable length 15 m (49 ft) (shielded) for PM340 Power Modules with integrated line filter to maintain the limit values of EN 61800-3 Category C2.

 

Line voltage 380 … 480 V 3 AC

PM340 Power Module in blocksize format

 

6SL3210-...

1SE16?0...

1SE17?7...

1SE21?0...

1SE21?8...

1SE22?5...

1SE23?2...

Output current

 

 

 

 

 

 

 

  • Rated current Irated

A

5.9

7.7

10.2

18

25

32

  • Base-load current IH

A

5.2

6.8

9.1

14

21

27

  • For S6 duty (40%) IS6

A

6.4

8.3

10.8

19.6

27.8

37.1

  • Imax

A

11.8

15.4

20.4

26.4

38

52

Type rating 1)

 

 

 

 

 

 

 

  • Based on Irated

kW (HP)

2.2 (3)

3 (5)

4 (5)

7.5 (10)

11 (15)

15 (20)

  • Based on IH

kW (HP)

2.2 (3)

3 (4)

4 (5)

5.5 (10)

7.5 (15)

11 (20)

Rated pulse frequency

kHz

4

4

4

4

4

4

Power loss

kW

0.14

0.16

0.18

0.24

0.30

0.40

Cooling air requirement

m3/s (ft3/s)

0.009 (0.3)

0.009 (0.3)

0.009 (0.3)

0.038 (1.3)

0.038 (1.3)

0.038 (1.3)

Sound pressure level LpA (1 m)

dB

< 50

< 50

< 50

< 60

< 60

< 60

24 V DC power supply

For Control Unit

A

1.0

1.0

1.0

1.0

1.0

1.0

Rated input current 2)

With/without line reactor

A

5.6/6.7

7.5/8.9

9.8/12.4

17.1/23.1

24.6/32.6

33/39

Resistance value

External braking resistor

?

? 160

? 160

? 160

? 56

? 56

? 56

Cable length

To braking resistor, max.

m (ft)

15 (49)

15 (49)

15 (49)

15 (49)

15 (49)

15 (49)

Line connection

U1/L1, V1/L2, W1/L3

 

Screw-type terminals

Screw-type terminals

Screw-type terminals

Screw-type terminals

Screw-type terminals

Screw-type terminals

  • Conductor cross-section

mm2

1.0 … 6

1.0 … 6

1.0 … 6

2.5 … 10

2.5 … 10

2.5 … 10

Motor connection

U2, V2, W2

 

Screw-type terminals

Screw-type terminals

Screw-type terminals

Screw-type terminals

Screw-type terminals

Screw-type terminals

  • Conductor cross-section

mm2

1.0 … 6

1.0 … 6

1.0 … 6

2.5 … 10

2.5 … 10

2.5 … 10

DC link connection,
connection for the braking resistor

DCP/R1, DCN, R2

 

Screw-type terminals

Screw-type terminals

Screw-type terminals

Screw-type terminals

Screw-type terminals

Screw-type terminals

  • Conductor cross-section

mm2

1.0 … 6

1.0 … 6

1.0 … 6

2.5 … 10 10

2.5 … 10 10

2.5 … 10 10

PE connection

 

M5 screw

M5 screw

M5 screw

M5 screw

M5 screw

M5 screw

Motor cable length 3), max.

 

 

 

 

 

 

 

  • Shielded

m (ft)

50 (164)

50 (164)

50 (164)

50 (164)

50 (164)

50 (164)

  • Unshielded

m (ft)

75 (246)

75 (246)

75 (246)

75 (246)

75 (246)

75 (246)

Degree of protection

 

IP20

IP20

IP20

IP20

IP20

IP20

Dimensions

 

 

 

 

 

 

 

  • Width

mm (in)

153 (6.02)

153 (6.02)

153 (6.02)

188.4 (7.42)

188.4 (7.42)

188.4 (7.42)

  • Height

mm (in)

270 (10.63)

270 (10.63)

270 (10.63)

333.4 (13.13)

333.4 (13.13)

333.4 (13.13)

  • Depth

 

 

 

 

 

 

 

  • PM340

mm (in)

165 (6.50)

165 (6.50)

165 (6.50)

185 (7.28)

185 (7.28)

185 (7.28)

  • PM340 with CU310

mm (in)

254.6 (10.02)

254.6 (10.02)

254.6 (10.02)

274.6 (10.81)

274.6 (10.81)

274.6 (10.81)

  • PM340 with CUA31

mm (in)

195.3 (7.69)

195.3 (7.69)

195.3 (7.69)

215.3 (8.48)

215.3 (8.48)

215.3 (8.48)

Frame size

 

FSB

FSB

FSB

FSC

FSC

FSC

Net weight

kg (lb)

4.0 (9)

4.0 (9)

4.0 (9)

6.5 (14.3)

6.5 (14.3)

6.5 (14.3)



1) Nominal HP based on asynchronous motors and 460 V AC. For specific sizing select drive based on motor nameplate current and overload.

2) The input current depends on the motor load and line impedance. The input currents apply for rated power loading (based on Irated) for a line impedance corresponding to uk = 1 %.

3) Max. motor cable length 15 m (49 ft) (shielded) for PM340 Power Modules with integrated line filter to maintain the limit values of EN 61800-3 Category C2.

Line voltage 380 … 480 V 3 AC

PM340 Power Module in blocksize format

 

6SL3210-...

1SE23?8...

1SE24?5...

1SE26?0...

1SE27?5...

1SE31?0...

Output current

 

 

 

 

 

 

  • Rated current Irated

A

38

45

60

75

90

  • Base-load current IH

A

33

40

48

65

80

  • For S6 duty (40%) IS6

A

49

58

78

98

117

  • Imax

A

64

76

90

124

150

Type rating 1)

 

 

 

 

 

 

  • Based on Irated

kW (HP)

18.5 (25)

22 (30)

30 (40)

37 (50)

45 (60)

  • Based on IH

kW (HP)

15 (20)

18.5 (30)

22 (30)

30 (50)

37 (60)

Rated pulse frequency

kHz

4

4

4

4

4

Power loss

kW

0.38

0.51

0.69

0.99

1.21

Cooling air requirement

m3/s (ft3/s)

0.022 (0.8)

0.022 (0.8)

0.039 (1.4)

0.022 (0.8)

0.039 (1.4)

Sound pressure level LpA (1 m)

dB

< 60

< 60

< 61

< 60

62

24 V DC power supply

For Control Unit

A

1.0

1.0

1.0

1.0

1.0

Rated input current 2)

With/without line reactor

A

40/46

47/53

63/72

78/88

94/105

Resistance value

External braking resistor

?

? 27

? 27

? 27

? 15

? 15

Cable length

To braking resistor, max.

m (ft)

15 (49)

15 (49)

15 (49)

15 (49)

15 (49)

Line connection

U1/L1, V1/L2, W1/L3

 

M6 screw stud

M6 screw stud

M6 screw stud

M6 screw stud

M6 screw stud

  • Conductor cross-section

mm2

10 … 35

10 … 35

10 … 35

10 … 35

10 … 35

Motor connection

U2, V2, W2

 

M6 screw stud

M6 screw stud

M6 screw stud

M6 screw stud

M6 screw stud

  • Conductor cross-section

mm2

10 … 35

10 … 35

10 … 35

10 … 35

10 … 35

DC link connection,
connection for the braking resistor

DCP/R1, DCN, R2

 

M6 screw stud

M6 screw stud

M6 screw stud

M6 screw stud

M6 screw stud

  • Conductor cross-section

mm2

10 … 35

10 … 35

10 … 35

10 … 35

10 … 35

PE connection

 

M6 screw

M6 screw

M6 screw

M6 screw

M6 screw

Motor cable length 3), max.

 

 

 

 

 

 

  • Shielded

m (ft)

70 (230)

70 (230)

70 (230)

70 (230)

70 (230)

  • Unshielded

m (ft)

100 (328)

100 (328)

100 (328)

100 (328)

100 (328)

Degree of protection

 

IP20

IP20

IP20

IP20

IP20

Dimensions

 

 

 

 

 

 

  • Width

mm (in)

275 (10.83)

275 (10.83)

275 (10.83)

275 (10.83)

275 (10.83)

  • Height
    PM340 without/with int. filter

mm (in)

418.3/511 (16.47/20.12)

418.3/511 (16.47/20.12)

418.3/511 (16.47/20.12)

498.3/633 (19.62/24.92)

498.3/633 (19.62/24.92)

  • Depth

 

 

 

 

 

 

  • PM340

mm (in)

203.5 (8.01)

203.5 (8.01)

203.5 (8.01)

203.5 (8.01)

203.5 (8.01)

  • PM340 with CU310

mm (in)

293.1 (11.54)

293.1 (11.54)

293.1 (11.54)

293.1 (11.54)

293.1 (11.54)

  • PM340 with CUA31

mm (in)

233.8 (9.20)

233.8 (9.20)

233.8 (9.20)

233.8 (9.20)

233.8 (9.20)

Frame size

 

FSD

FSD

FSD

FSE

FSE

Net weight

PM340 without/with int. filter

kg (lb)

15.9/19.3 (35/43)

15.9/19.3 (35/43)

15.9/19.3 (35/43)

19.8/27.1 (44/60)

19.8/27.1 (44/60)



1) Nominal HP based on asynchronous motors and 460 V AC. For specific sizing select drive based on motor nameplate current and overload.

2) The input current depends on the motor load and line impedance. The input currents apply for rated power loading (based on Irated) for a line impedance corresponding to uk = 1 %.

3) Max. motor cable length 15 m (49 ft) (shielded) for PM340 Power Modules with integrated line filter to maintain the limit values of EN 61800-3 Category C2.

Line voltage 380 … 480 V 3 AC

PM340 Power Module in blocksize format

 

6SL3210-...

1SE31?1...

1SE31?5...

1SE31?8...

Output current

 

 

 

 

  • Rated current Irated

A

110

145

178

  • Base-load current IH

A

95

115

155

  • For S6 duty (40%) IS6

A

143

188

231

  • Imax

A

180

220

290

Type rating 1)

 

 

 

 

  • Based on Irated

kW (HP)

55 (75)

75 (100)

90 (125)

  • Based on IH

kW (HP)

45 (60)

55 (75)

75 (100)

Rated pulse frequency

kHz

4

4

4

Power loss

kW

1.42

1.93

2.31

Cooling air requirement

m3/s (ft3/s)

0.094 (3.3)

0.094 (3.3)

0.117 (4.1)

Sound pressure level LpA (1 m)

dB

< 60

< 60

65

24 V DC power supply

For Control Unit

A

1.0

1.0

1.0

Rated input current 2)

With/without line reactor

A

115/129

151/168

186/204

Resistance value

External braking resistor

?

? 8.2

? 8.2

? 8.2

Cable length

To braking resistor, max.

m (ft)

15 (49)

15 (49)

15 (49)

Line connection

U1/L1, V1/L2, W1/L3

 

M8 screw stud

M8 screw stud

M8 screw stud

  • Conductor cross-section, max.

mm2

120

120

120

Motor connection

U2, V2, W2

 

M8 screw stud

M8 screw stud

M8 screw stud

  • Conductor cross-section, max.

mm2

120

120

120

DC link connection,
connection for the braking resistor

DCP/R1, DCN, R2

 

M8 screw stud

M8 screw stud

M8 screw stud

  • Conductor cross-section, max.

mm2

120

120

120

PE connection

 

M8 screw

M8 screw

M8 screw

Motor cable length 3), max.

 

 

 

 

  • Shielded

m (ft)

70 (230)

70 (230)

70 (230)

  • Unshielded

m (ft)

100 (328)

100 (328)

100 (328)

Degree of protection

 

IP20

IP20

IP20

Dimensions

 

 

 

 

  • Width

mm (in)

350 (13.78)

350 (13.78)

350 (13.78)

  • Height, PM340 without/with int. filter

mm (in)

634/934 (24.96/36.77)

634/934 (24.96/36.77)

634/934 (24.96/36.77)

  • Depth

 

 

 

 

  • PM340

mm (in)

315.5 (12.42)

315.5 (12.42)

315.5 (12.42)

  • PM340 with CU310

mm (in)

405.1 (15.95)

405.1 (15.95)

405.1 (15.95)

  • PM340 with CUA31

mm (in)

345.8 (13.61)

345.8 (13.61)

345.8 (13.61)

Frame size

 

FSF

FSF

FSF

Net weight

PM340 without/with int. filter

kg (lb)

50.7/66.7 (112/147)

50.7/66.7 (112/147)

50.7/66.7 (112/147)



1) Nominal HP based on asynchronous motors and 460 V AC. For specific sizing select drive based on motor nameplate current and overload.

2) The input current depends on the motor load and line impedance. The input currents apply for rated power loading (based on Irated) for a line impedance corresponding to uk = 1 %.

3) Max. motor cable length 15 m (49 ft) (shielded) for PM340 Power Modules with integrated line filter to maintain the limit values of EN 61800-3 Category C2.

















skener.ru

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Àðìàòóðà DENDOR

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Äàò÷èêè è èçìåðèòåëè

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Ðåãóëÿòîðû è ðåãèñòðàòîðû

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Ïíåâìàòè÷åñêîå îáîðóäîâàíèå

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Êðàíû è Êëàïàíû

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Èçìåðèòåëüíûå ïðèáîðû

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Ñèñòåìû áåñïðîâîäíîãî óïðàâëåíèÿ «óìíûé äîì»

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Áåñêîíòàêòíûå âûêëþ÷àòåëè Êîíå÷íûå âûêëþ÷àòåëè Îïòè÷åñêèå äàò÷èêè Ýíêîäåðû

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
SKW-FS - Óñòàíîâêà óìÿã÷åíèÿ

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
SKW-FK - Óñòàíîâêà îáåçæåëåçèâàíèÿ
Êàòàëîã îáîðóäîâàíèÿ 2017
Siemens Industry Catalog Drive Technology Automation Technology Energy Building Technologies Low-Voltage Controls and Distribution Safety Systems - Safety Integrated Market-specific solutions Automotive industry Biofuels and bioenergy Chemical and petrochemical industries Food, drinks and tobacco industry Machine building Packaging machines Printing presses Textile machines Converting Tire production machines Metal forming technology Glass production machines Handling systems Solar production machines Ceramics and stone processing machines Cranes Plastics Machine Tools SINUMERIK 808 with SINAMICS V60/V70 SINUMERIK 828 with SINAMICS S120 SINUMERIK 840 with SINAMICS S120 Introduction SINUMERIK 840D sl with SINAMICS S120 SINUMERIK CNC control SINUMERIK Operate SINUMERIK Integrate SINAMICS S120 drive system Communication Engineering software Control Units Booksize format Chassis format Blocksize format Power Modules Line reactors for blocksize format Line filters for blocksize format Recommended line-side power components for blocksize format Braking resistors for blocksize format Line reactors Line filters Recommended line-side components Braking resistors for blocksize format SINAMICS S120 Combi SINAMICS S120M distributed servo drive Supplementary system components Encoder system connection Motion Control Encoder measuring systems CAD CREATOR SIMOTICS motors MOTION-CONNECT connection systems Lifecycle Services SINUMERIK Solution Partners Certificates of suitability (approvals) Glossary SINUMERIK 840 Glossary SINAMICS S120 drive system List of abbreviations Drive applications Mining and Metals Oil and gas industry Pharmaceutical industry Pulp and paper industry Water / wastewater Electrical wholesale Industry Services ... and everything else you need




  © ÎÎÎ "ÑÊ ÝÍÅÐÃÎ" 2007-2022
  (4872) 700-366  skenergo@mail.ru
ßíäåêñ.Ìåòðèêà