Overload capabilityLoad cycle data for Single Motor Modules in chassis format The base-load current IL is based on a load cycle of 110 % for 60 s or 150 % for 10 s with a load cycle duration of 300 s. Low overload The base-load current IH is based on a load cycle of 150 % for 60 s or 160 % for 10 s with a load cycle duration of 300 s. High overload Derating factorsWhen the pulse frequency is increased, the derating factor of the output current must be taken into account. This derating factor must be applied to the currents specified in the technical specifications. Derating factor of the output current dependent on pulse frequency for devices with a rated pulse frequency of 2 kHz
Current derating dependent on ambient temperature Note: A derating factor kT > 1.0 is applicable only in conjunction with "current derating as a function of installation altitude". The rated current data may not be exceeded. For further information see System description. Current derating dependent on installation altitude Voltage derating dependent on installation altitude |