Drive system | SINAMICS S120 |
Electronics power supply | 24 V DC, -15%/+20% |
Vibratory load | |
- Transport 1) acc. to EN 60721-3-2
| |
- All units and components except for chassis format
| Class 2M3 |
| Class 2M2 |
- Operation
Test values acc. to EN 60068?2?6
| Test Fc |
| 10 ... 58 Hz: Constant deflection, 0.075 mm (0.003 in) 58 ... 150 Hz: Constant acceleration = 9.81 m/s2 (3.2 ft/s2) (1 ? g) |
Shock load | |
- Transport1) acc. to EN 60721-3-2
| |
- All units and components except for chassis format
| Class 2M3 |
| Class 2M2 |
- Operation
Test values acc. to EN 60068?2?27
| Test Ea |
- Booksize and blocksize formats FSA to FSB
| 147 m/s2 (482 ft/s2) (15 ? g)/11 ms |
- Blocksize format FSC to FSF
| 49 m/s2 (161 ft/s2) (5 ? g)/30 ms |
| 98 m/s2 (321 ft/s2) (10 ? g)/20 ms |
Ambient conditions | |
- Protection class according to EN 61800?5?1
| Class I (with protective conductor system) and Class III (PELV) |
| DIN VDE 0106 Part 100 and BGV A 3 when used properly |
| Internal/external air cooling, power units with increased air cooling by means of built-in fan |
Permissible ambient/coolant temperature (air) during operation | |
- For line-side components, Power Modules, Line Modules and Motor Modules
| 0 ... 40 °C (32 ... 104 °F) without derating, > 40 ... 55 °C (104 ... 131 °F), see derating characteristics |
- For Control Units, supplementary system components, DC link components and Sensor Modules
| 0 … 55 °C (32 … 131 °F) up to 2000 m (6562 ft) above sea level |
Climatic ambient conditions | |
- Storage1) acc. to EN 60721?3?1
| Class 1K4 Temperature -25 ... +70 °C (-13 ... +158 °F) |
- Transport1) acc. to EN 60721-3-2
| Class 2K4 Temperature -40 … +70 °C (-40 ... +158 °F) Max. air humidity 95 % at 40 °C (104 °F) |
- Operation according to EN 60721?3?3
| Class 3K3 Temperature 0 ... 55 °C (32 ... 131 °F) Condensation, splashwater and ice formation are not permitted (EN 60204, Part 1) |
Environmental class/harmful chemical substances | |
- Storage1) acc. to EN 60721?3?1
| Class 1C2 |
- Transport1) acc. to EN 60721-3-2
| Class 2C2 |
- Operation according to EN 60721?3?3
| Class 3C2 |
Organic/biological influences | |
- Storage1) acc. to EN 60721?3?1
| Class 1B1 |
- Transport1) acc. to EN 60721-3-2
| Class 2B1 |
- Operation according to EN 60721?3?3
| Class 3B1 |
Degree of contamination According to EN 61800?5?1 | 2 |